P Characteristics P Electrostatic capacitance Between open Contacts Approx.0.4pF Item 4.41 of IEC 61810-7 Between coil & Contacts Approx.0.9pF Item 4.41 of IEC 61810-7 R Between Contact Poles Approx.0.2pF Item 4.41 of IEC 61810-7 E169380 R50044271 C US 14.0 9.0 5.0 1000M min (at 500VDC) Item 7 of IEC 61810-5 Insulation Resistance Dielectric Strength Features Between open Contacts 1000VAC 1min Item 6 of IEC 61810-5 DIL Pitch Terminals .High Sensitivity :0.14W or 0.10W Nominal Power Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC Between coil & Contacts 1000VAC 1min Item 6 of IEC 61810-5 Monostable or bistable relays Single and double Coil magnet latching Type available Between Contact Poles 1000VAC 1min Item 6 of IEC 61810-5 Application for Telecommunication Equipment,Office Equipment,Security Alarm Systems, Measuring instruments, Surge Withstand Voltage Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control Between open Contacts 1500V FCC68 Between coil & Contacts 1500V FCC68 Ordering Information Between Contact Poles 2500V FCC68 2 P L 12 W Functional:500m/s 11ms IEC68-2-27 Test Ea Shock resistance 2 1 2 3 4 Survival:1000 m/s 6ms 1 Part number P 3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24 10~55Hz Double amplitude Functional 3mm 2 Operating function NIL: Single Side Stable 4 Contact material NIL: AgPd W: AgNi IEC68-2-6 Test Fc Vibration resistance Survival:5mm L:1 Coil Latching K:2 Coil Latching Terminals strength 5N IEC68-2-21 Test Ua1 Contact Data Solderability 235 2 3 0.5s IEC68-2-20 Test Ta method 1 Contact Arrangement 2C DPDT(B-M) Bifurcated Crossbar Temperature Range -40~70 (-40~158 F) Contact Material AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad Mass 1.5g Contact Rating (resistive) 1A,2A/30VDC 0.5A/125VAC Max. Switching Power 60W 62.5VA Min. Switching load 0.01mA/10mV Reference Value Max. Switching Voltage 220VDC 250VAC Max. Switching Current:2A Safety approvals Contact Resistance or 50m Item 4.12 of IEC 61810-7 Safety approval UL&CUR T VU Voltage drop 5 5 1A/30VDC 2 10 Ag Ni 1 10 Load 1A,2A/30VDC, 0.5A/125VAC 1A/30VDC, 0.5A/125VAC Operation Electrical 5 0.5A/125VAC 1 10 Item 4.30 of IEC 61810-7 life 8 Mechanical 10 Item 4.31 of IEC 61810-7 Dimensions mm/inch CAUTION: Relays previously tested or used above 10mA resistive at 6V maximum DC or peak AC open circuit are not recommended for subsequent use in low level applications. Coil Parameter Coil voltage Index Mark Pick up voltage Release voltage Release VDC Coil Operate Dash VDC(max) VDC(min) Coil resistance /Reset power Time numbers 10% (75%of rated (10% of rated Time 0.5 Rated Max. 0.25 W ms 0.02 voltage ) voltage) ms 0.01 P-003 3 7.5 64.3 2.25 0.3 0.14 7.62 2.54 P-004 4.5 11.25 144.6 3.38 0.45 0.14 14max. 0.3 0.1 0.55max. P-005 5 12.5 178 3.75 0.5 0.14 Approx.2 Approx.1 P-006 6 15.0 257 4.50 0.6 0.14 Dimensions P-009 9 22.5 579 6.75 0.9 0.14 2 .5 4 P-012 12 30.0 1028 9.00 1.2 0.14 0.1 P-024 24 48.0 2880 18.0 2.4 0.20 Single Side stable 1 Coil latching 2 Coil latching 1 Coil Latching Reset(Max) Reset 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 PL-003 3 8.7 90 2.25 -2.25 0.10 PL-004 4.5 13.0 202.5 3.38 -3.38 0.10 S R PL-005 5 14.5 250 3.75 -3.75 0.10 S PL-006 6 17.4 360 4.50 -4.50 0.10 Approx.2 Approx.1 R S: Set PL-009 9 26.1 810 6.75 -6.75 0.10 R: Reset PL-012 12 34.8 1440 9.00 -9.00 0.10 (Bottom View) PL-024 24 57.6 3840 18.0 -18.0 0.15 10 9 8 7 6 10 9 8 7 6 10 9 8 7 6 2 Coil Latching Set Coil Reset Coil Reset(Max) Reset Index mark Index mark Index mark 10- 1 (De-energized Position) (Reset Position) (Reset Position) PK-003 3 6 45 45 2.25 2.25 0.20 0 .0 4 PK-004 4.5 9 101 101 3.38 3.38 0.20 Wiring diagram Tole ra n c e : 0 .1 / 0 .0 0 4 PK-005 5 10 125 125 3.75 3.75 0.20 PK-006 6 12 180 180 4.50 4.50 0.20 (Bottom view) Approx.2 Approx.1 Mounting (Bottom view) 405 PK-009 9 18 405 6.75 6.75 0.20 PK-012 12 24 720 720 9.00 9.00 0.20 PK-024 24 36 1920 1920 18.0 18.0 0.30 NOTES 1).Dimensions are in millimeters. CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2).Inch equivalents are given for general information only. 2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design criteria. 3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magnetically neutral position . 9 m a x . 0 . 3 5 4 m a x . +0.4 5 +0.016 0.197 3.5 4 . 7 5 0 . 1 8 7 0.187 2.54 0.1