Dimensions: mm Recommended Land Pattern: mm General Properties: Type Optocoupler Phototransistor Input AC Package SOP 4 2 7,4 3 Plastic Housing Color White 5,2 4 Certification: 1 1 4 RoHS Approval Compliant 2011/65/EU&2015/863 7,0 0,3 REACh Approval Conform or declared (EC)1907/2006 Halogen Free Conform JEDEC JS709B 2 3 Halogen Free Conform IEC 61249-2-21 40051484 DIN EN 60747-5-5 (VDE0884-5) EN VDE Approval 5,2 0,3 60747-5-5:2011 A1:2015 4,4 0,2 Scale - 5:1 UL Approval E513104 UL 1577 CQC Approval CQC20001274583 GB4943.1-2001 GB8898-2011 Schematic: 0,5 typ . General Information: Operating Temperature -55 up to +110 C Storage Conditions (for single 1 4 -55 up to +125 C parts) Anode/ Cathode Collector 1 4 Storage Conditions (in original < 40 C < 75 % RH packaging) 2 3 Moisture Sensitivity Level (MSL) 1 23 Cathode/ Anode Emitter Scale - 5:1 Product Marking: Pin 1 Anode o CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD Marking 354A (Series 354, Binning A) SaVog 001.002 2022-01-05 DIN ISO 2768-1m Marking - Date Code YWW DESCRIPTION WL-OCPT Optocoupler Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Phototransistor Max-Eyth-Str. 1 140354245100 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com SOP4 eiPal Valid 1/12 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 3,6 0,2 0,2 typ . 0,4 typ . 2,54 typ. 2,0 0,1 0,1 typ . 2,1 typ . 1,64 3,44Absolute Maximum Ratings Input Properties (Ambient Temperature 25 C unless Electrical & Optical Output Properties: otherwise specified): Value Properties Test conditions Unit Properties Test conditions Value Unit min. max. Forward Current I 60 mA V = 20 V F max. Collector-Emitter Dark Current I 100 nA CE I = 0 I CEO.Dark Peak Forward Current duty/ 100 100 Hz 1 A F F Peak P Input Power Dissipation 100 mW I = 100 A I Collector-Emitter Breakdown V C 80 V I = 0 Voltage (BR)CE F Absolute Maximum Ratings Output Properties: I = 100 A Emitter-Collector Breakdown V E 7 V I = 0 Properties Value Unit Voltage (BR)EC F V Collector Emitter Voltage 80 V CE V Electrical & Optical Transfer Properties: Emitter Collector Voltage 7 V EC I Collector Current 50 mA Value CE.P Properties Test conditions Unit P Output Power Dissipation 150 mW min. typ. max. O I = +/- 1 mA Current Transfer Ratio CTR F 50 150 % Absolute Maximum Ratings Common Properties: V = 5 V CE Properties Test conditions Value Unit I = +/- 1 mA CTR CTR Symmetry 0.7 1.3 F V = 5 V P Power Dissipation 1) 200 mW SYM Diss CE V Isolation Voltage AC for 1 Minute, RH 40~60 % 3750 V (RMS) ISO I = +/- 20 mA Collector-Emitter Saturation V F 0.07 0.2 V I = 1 mA Voltage CEsat 1) Total power dissipation of the whole component C V = 2 V Electrical & Optical Input Properties: CE t I = 2 mA Rise Time 5 18 s r C R = 100 Value L Properties Test conditions Unit typ. max. V = 2 V V I = +/- 10 mA Forward Voltage 1.24 1.4 V CE F F t I = 2 mA Fall Time 6 18 s f C R = 100 V = 0 V L C Input Capactiance 10 pF in f = 1 kHz V = 0 V Floating Capacitance C 0.4 pF f = 1 MHz IO DC = 500 V R Isolation Resistance 1 100 T ISO 40~60 % R.H. CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD SaVog 001.002 2022-01-05 DIN ISO 2768-1m DESCRIPTION WL-OCPT Optocoupler Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Phototransistor Max-Eyth-Str. 1 140354245100 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com SOP4 eiPal Valid 2/12 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.