Dimensions: mm Recommended Land Pattern: mm Absolute Maximum Ratings (Ambient Temperature 25C): Properties Test conditions Value Unit Power Dissipation P 105 mW Diss I Peak Forward Current duty/ 10 1 kHz 40 mA F Peak 1,2 0,55 2 I Continuous Forward Current 30 mA F 2 1 Reverse Voltage V 5 V REV ESD Threshold/ Human Body V 2000 V 2 1 Model ESD HBM 0,83 1,6 Absolute Thermal Resistance R 50 K/W Junction to Solder Point JS 0,12 T Junction Temperature 125 C J Optical Properties: 3 Scale - 12:1 Chip Technology InGaN Emitting Color Cool White Schematic: Lens Type Top LED General Information: Operating Temperature -40 up to +85 C Storage Conditions (in original < 40 C < 90 % RH 2 1 packaging) - + 1 2 Storage Conditions (for single -40 up to +85 C parts) Polarity Mark Anode Moisture Sensitivity Level (MSL) 3 Scale - 12:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD DoK 007.000 2021-06-10 DIN ISO 2768-1m DESCRIPTION WL-SWTP SMT White Top view Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions PLCC Max-Eyth-Str. 1 158301260 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 3014 eiPal Valid 1/10 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 1,4 0,8 0,8 0,8Electrical & Optical Properties: Viewing Angle: Value Properties Test conditions Unit min. typ. max. c Chromaticity Coordinate X 20 mA 0.3233 x c Chromaticity Coordinate Y 20 mA 0.3327 y Luminous Flux 20 mA 7 9 lm V V Forward Voltage 20 mA 3 3.5 V F Correlated Color Temperature CCT 20 mA 6000 K Reverse Current I 5 V 5 A REV 0 - 60 Color Rendering Index CRI 20 mA 85 90 10 100 20 2 Viewing Angle Phi 0 20 mA 120 50% 30 90 40 80 Certification: 45 RoHS Approval Compliant 2011/65/EU&2015/863 70 50 REACh Approval Conform or declared (EC)1907/2006 60 Halogen Free Conform JEDEC JS709B 50 60 Halogen Free Conform IEC 61249-2-21 40 Photobiological Safety IEC-62471 Exempt Group 0 70 30 20 80 10 90 -90 -45 0 10 20 30 40 50 60 70 80 90 100 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD DoK 007.000 2021-06-10 DIN ISO 2768-1m DESCRIPTION WL-SWTP SMT White Top view Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions PLCC Max-Eyth-Str. 1 158301260 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 3014 eiPal Valid 2/10 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Relative Luminous Intensity (%)