Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Frequency Range f 2400 - 2500 MHz 1,3 Insertion Loss IL 2400 - 2500 MHz 2.2 dB max. VSWR 2400 - 2500 MHz 2 max. Attenuation att I 500 - 1000 MHz 25 dB min. Attenuation att II 1000 - 1700 MHz 20 dB min. Attenuation att III 2100 MHz 10 dB min. Attenuation att IV 3500 - 4000 MHz 25 dB min. Attenuation att V 4100 MHz 30 dB min. 1,4 1,0 2,00 0,15 1,25 0,1 Scale - 10:1 General Information: 1,30 0,15 0,35 0,15 It is recommended that the temperature of the component does not exceed +85C under worst case conditions Storage Conditions (in original < 40 C < 75 % RH packaging) Operating Temperature -40 up to +85 C Moisture Sensitivity Level (MSL) 1 Test Board 7483230EB Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 10:1 CREATED CHECKED GENERAL TOLERANCE PROJECTION Wrth Elektronik eiSos GmbH & Co. KG METHOD EMC & Inductive Solutions KaS MuK DIN ISO 2768-1m Max-Eyth-Str. 1 DESCRIPTION 74638 Waldenburg Germany WE-BPF Multilayer Chip Band- Tel. +49 (0) 79 42 945 - 0 ORDER CODE Pass Filter www.we-online.com 748323024 eiSos we-online.com SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE 002.000 Valid 2018-09-15 eiSos 1/7 0805 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 0,25 0,15 0,30 0,15 0,95 0,1 0,8 1,0 0,35 2,8Port1 Port2 Network Analyzer (50 ) (50 ) GND I/O I/O GND NO. Terminal Name NO. Terminal Name GND GND OUT IN CREATED CHECKED GENERAL TOLERANCE PROJECTION Wrth Elektronik eiSos GmbH & Co. KG METHOD EMC & Inductive Solutions KaS MuK DIN ISO 2768-1m Max-Eyth-Str. 1 DESCRIPTION 74638 Waldenburg Germany WE-BPF Multilayer Chip Band- Tel. +49 (0) 79 42 945 - 0 ORDER CODE Pass Filter www.we-online.com 748323024 eiSos we-online.com SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE 002.000 Valid 2018-09-15 eiSos 2/7 0805 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.