Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 125 kHz/ 10 mA L 7.5 H 10% Q-Factor 125 kHz/ 10 mA Q 45 typ. 37,0 max. Rated Current T = 40 K I 3 A max. Heat shrinkable R Tubing (black) Saturation Current I 6 A typ. SAT O 2,0 DC Resistance 20 C R 150 m typ. DC 1 2 DC Resistance 20 C R 180 m max. DC 5,0 min. Self Resonant Frequency f 22 MHz 28,0 1,5 45,0 3,0 res 6,0 ref. 2 Scale - 1:1,5 10,0 2,0 1 Schematic: 16,2 1,0 General Information: It is recommended that the temperature of the component does not exceed +105C under worst case conditions Operating Temperature -20 C up to +105 C Storage Temperature (in original -20 C up to +65 C packaging) Test conditions of Electrical Properties: +20C, 33% RH if not specified differently Scale - 1:1 CREATED CHECKED GENERAL TOLERANCE PROJECTION Wrth Elektronik eiSos GmbH & Co. KG METHOD EMC & Inductive Solutions KaS CSo DIN ISO 2768-1m Max-Eyth-Str. 1 DESCRIPTION 74638 Waldenburg Germany WE-WPCC Wireless Power Tel. +49 (0) 79 42 945 - 0 ORDER CODE Charging Receiver Coil www.we-online.com 760308102210 eiSos we-online.com SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE 001.004 Valid 2017-04-24 eiSos 1/6 3737 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 37,0 max. 1,8 typ. O 0,6Typical Inductance vs. Current Characteristics: Typical Inductance vs. Frequency Characteristics: 9.0 100 8.0 7.0 6.0 5.0 10 4.0 3.0 2.0 1.0 1 10 100 1000 10000 100000 0.0 0.0 2.0 4.0 6.0 8.0 10.0 Frequency kHz Current A CREATED CHECKED GENERAL TOLERANCE PROJECTION Wrth Elektronik eiSos GmbH & Co. KG METHOD EMC & Inductive Solutions KaS CSo DIN ISO 2768-1m Max-Eyth-Str. 1 DESCRIPTION 74638 Waldenburg Germany WE-WPCC Wireless Power Tel. +49 (0) 79 42 945 - 0 ORDER CODE Charging Receiver Coil www.we-online.com 760308102210 eiSos we-online.com SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE 001.004 Valid 2017-04-24 eiSos 2/6 3737 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Inductance H Inductance H