Dimensions: mm Recommended Hole Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. 28,9 0,2 Inductance L 125 kHz/ 10 mA 7.5 H 10% Q-Factor Q 125 kHz/ 10 mA 16 typ. Rated Current DC I T = 40 K 1.55 A max. R DC O 1,0 Power Capability P V = 20 V 20 W typ. DC Saturation Current I 3 A typ. 1 2 SAT DC Resistance R 20 C 340 m typ. DC 2,0 min. DC Resistance R 20 C 380 m max. DC Self Resonant Frequency f 23 MHz detail A res A Certification: RoHS Approval Compliant 2011/65/EU&2015/863 Scale - 2:1 REACh Approval Conform or declared (EC)1907/2006 Release Tape 27,25 0,5 Halogen Free Conform JEDEC JS709B 14,73 0,3 Schematic: General Information: 5,0 2 25,0 2 It is recommended that the temperature of the component does not exceed +105C under worst case conditions Operating Temperature -20 up to +105 C Storage Conditions (in original < 40 C < 75 % RH packaging) Moisture Sensitivity Level (MSL) 1 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 1,5:1 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD CMe 002.000 2020-01-01 DIN ISO 2768-1m DESCRIPTION WE-WPCC Wireless Power Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Transfer Receiver Coil Max-Eyth-Str. 1 760308103206 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 28 x 15 x 0.7 mm eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 15,3 0,3 1,72 +0,3 15,7 0,1 2,0 0,76 0,3 0,048 Adhesvie TapeTypical Inductance vs. Current Characteristics: Typical Inductance vs. Frequency Characteristics: 8.0 100 7.0 6.0 5.0 10 4.0 3.0 2.0 1.0 1 10 100 1000 10000 100000 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Frequency kHz Current A CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD CMe 002.000 2020-01-01 DIN ISO 2768-1m DESCRIPTION WE-WPCC Wireless Power Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Transfer Receiver Coil Max-Eyth-Str. 1 760308103206 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 28 x 15 x 0.7 mm eiSos Valid 2/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Inductance H Inductance H