AC-DC Power Supplies ACM06 Series 6 Watt Energy Efficiency Level VI xxx Series European CoC Tier 2 Medical and ITE Approvals Interchangeable Mains Connectors Optional White Versions Output Voltages from 5 V to 12 V Class II Construction 3 Years Warranty Dimensions: The ACM06 series of wall plug adaptors comply with the latest energy efficiency level VI standards ACM (body only): with high active mode efficiency and extremely low no load power consumption. Available with a 2.89 x 1.21 x 1.67 (73.5 x 30.7 x 42.5 mm) standard jack plug connector as well as USB versions, these adaptors suit a wide variety of cost sensitive industrial and medical applications while maintaining industry leading performance. Models & Ratings (3) (4) (1,2,5) Output Power Output Voltage Output Current Total Regulation Efficiency Model Number (6) 5.0 V 1000 mA 5% 80.0% ACM06US05 6 W 9.0 V 600 mA 5% 79.8% ACM06US09 12.0 V 500 mA 5% 82.0% ACM06US12 Notes 1. Model number is for body only. AC input plugs must be ordered separately, see 5. For white case version add suffix -W e.g. ACM06US12-W. MOQ applies, contact AC input plug section. sales for details. 2. Other output voltages available, contact sales for details. 6. For 5 V version with optional USB type A connector in case, add suffix -BB, 3. Total regulation includes initial set accuracy, line and load regulation. e.g ACM06US05-BB. 4. Typical average value measured at 115 VAC. Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC Input Frequency 47 63 Hz Input Current 0.2 A 100 VAC Inrush Current 70 A 240 VAC, cold start at 25 C Power Factor EN61000-3-2, class A No Load Input Power 75 mW Input Protection Internal fuse in line Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 5 12 V See Models and Ratings table Minimum Load 0 A No minimum load required Start Up Delay 4 s Start Up Rise Time 30 ms Hold Up Time 10 ms Full load and 100 VAC Total Regulation 5 % See Models and Ratings table Transient Response 4 % deviation For a 50% step load change at 0.15 A/s Measured with 20 MHz bandwidth and 10 F electrolytic in Ripple & Noise 150 mV pk-pk parallel with 0.1 F ceramic capacitor Short Circuit Protection Continuous, trip and restart (hiccup mode) with auto recovery Temperature Coefficient 0.05 %/ C www.xppower.com 1AC-DC Power Supplies ACM06 Series General Characteristic Minimum Typical Maximum Units Notes & Conditions Typical average of efficiencies measured at 25%, Efficiency 80 % 50%, 75% and 100% load and 115 VAC input Energy Efficiency Level VI Isolation 4000 VAC Input to Output, 2 x MOPP Leakage Current 20 100 A At 264 VAC, 60 Hz, from output to ground Switching Frequency 24 70 kHz Variable Mean Time Between Failure 250 kHrs MIL-HDBK-217F at 25 C GB Weight 0.22 (100) lb (g) Body only Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Derate from 100% load at 40 C to 50% load Operating Temperature 0 +60 C at 60 C Storage Temperature -20 +85 C Operating Humidity 5 90 % RH, non-condensing Operating Altitude 5000 m Cooling Natural convection 1 m drop onto concrete on each of 6 axes, non Shock operating Vibration 10 300 Hz 2 g, 0.3 decades/min, 15 mins for each of 3 axes EMC: Emissions Phenomenon Standard Test Level Notes & Conditions Conducted EN55032 Level B Radiated EN55032 Level B Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 EMC: Immunity Phenomenon Standard Test Level Criteria Notes & Conditions Medical Device EMC IEC60601-1-2 Ed.4.0 : 2014 as below Low Voltage PSU EMC EN61204-3 High severity level as below ESD Immunity EN61000-4-2 8 kV contact, 15 kV air A Radiated Immunity EN61000-4-3 10 V/m A EFT/Burst EN61000-4-4 Level 3 A Surge EN61000-4-5 Level 2 A Conducted Immunity EN61000-4-6 6 V A Magnetic Fields EN61000-4-8 30 A/m A Dip: 100% 10 ms A Dip: 70% 500 ms B EN61000-4-11 Int: 100% 5000 ms B Dip: 30% 25 AC Cycles A Dips and Interruptions Int: 100% 0.5 AC Cycle At 8 angles, A at 115 VAC, B at 100 VAC EN60601-1-2 Int: 100% 1 AC Cycle B Int.: >95% 5000 ms B www.xppower.com 2