VCE05 Series AC-DC POWER SUPPLIES CONVECTION 5W COOLED The VCE05 is a series of open frame and encapsulated AC-DC single output power supplies designed for low cost ITE and Industrial applications. The series provides two mechanical options including open frame and encapsulated PCB mount. With approvals to world-wide safety standards, compliance with class B for conducted and radiated emissions and a 130%, 30s peak load capability, these class II isolation parts benefit system designers with easy integration into a wide range of applications. Features Applications Compact Size Single Outputs from 3.3 to 48VDC Industrial Instrumentation IoT Open Frame & Encapsulated PCB Mount Electronics <0.3W No Load Input Power Peak Load Capability No External Components Required Security Technology Class II Dimensions Low Cost 3 Year Warranty VCE05: 1.30 x 1.10 x 0.75 (33.02 x 27.94 x 19.05 mm) VCE05-P: 1.20 x 1.00 x 0.705 (30.8 x 25.4 x 17.9 mm) Models & Ratings Output Current (1) Model Number Output Voltage Output Power (1) Nominal Peak VCE05US03 3.3VDC 1210mA 1573mA 5W VCE05US05 5.0VDC 1000mA 1300mA 5W VCE05US09 9.0VDC 550mA 722mA 5W VCE05US12 12.0VDC 410mA 541mA 5W VCE05US15 15.0VDC 330mA 433mA 5W VCE05US24 24.0VDC 210mA 270mA 5W VCE05US48 48.0VDC 100mA 135mA 5W Notes: 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. 2. For Open Frame version add suffix -P to model number, e.g. VCE05US12-P.AC-DC POWER SUPPLIES VCE05 Series Summary Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage Range 85 264 VAC Derate from 100% at 90VAC to 90% at 85VAC No Load Input Power 0.3 W Efficiency 78 % Model dependent Operating Temperature -25 +70 C Derate linearly from 100% at +50C to 50% at +70C EMC EN55022 Level B Conducted & Radiated, EN601000-3-2, EN61000-3-3, EN60601-1-2 Safety Approvals IEC62368-1, IEC60950-1, EN62368-1, UL62368-1 Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage Range 85 264 VAC Input Frequency 47 63 Hz Input Current - Full Load 0.10/0.06 A rms At 115/230VAC No Load Input Power 0.3 W Inrush Current 40 A At 230/277VAC, cold start 25C Earth Leakage Current Class II construction no earth Input Protection Internal T1.0 A/250 VAC fuse fitted in line Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 3.3 48 VDC Initial Set Accuracy 3/2 % At 50% load for 3.3 & 5V models/Other models Minimum Load 0 A No minimum load required Line Regulation 1.0 % Load Regulation 3/2 3% for 03 & 05 models, 2% for others from 10% to 100% load Start Up Delay 2 s Start Up Rise Time 14 ms Hold Up Time 6 9 ms At full load and 115VAC Deviation, recovery within 1% in less than 500s for a 25% load Transient Response 4 % change 180 mV pk-pk 3.3-5V, 20MHz bandwidth Ripple & Noise 1 % pk-pk 9V to 48V models, 20MHz bandwidth Overvoltage Protection 115 140 % Vnom Recycle input to reset Overload Protection 110 180 % Short Circuit Protection Trip & Restart (hiccup mode) Temperature Coefficient 0.05 %/C 2