36-100 Watts xppower.com AEB Series CEC2008 & EISA2007 Compliant Low Profile Single Outputs from 5 V to 48 V High Power Density Universal Input China Compulsory Certification (CCC) Qualified 3 Year Warranty Specification Input General Efficiency See tables Input Voltage 90-264 VAC Energy Efficiency AEB70: Level V Input Frequency 47-63 Hz All other models: Level IV Input Current AEB36: 1.00 A max Isolation AEB36: 3000 VAC Input to Output AEB45: 1.20 A max AEB45/70/100: 3000 VAC Input to Output, AEB70: 1.50 A max 1500 VAC Input to Ground. Negative AEB100: 1.85 A max output is connected to ground. For Inrush Current AEB36: 60 A max at 240 VAC optional 500 VAC output to ground AEB45: 70 A max at 240 VAC isolation add suffix -F to model number AEB70: 80 A max at 240 VAC Switching Frequency AEB36: 60 kHz typical, AEB45: 100 kHz AEB100: 120 A max at 240 VAC typical, AEB70: 65 kHz typical, Power Factor EN61000-3-2, class A AEB100: 80 kHz typical PFC converter Earth Leakage Current <3.5 mA (AEB45/70/100) 45 kHz typical main converter 3 3 Input Protection Fitted with an internal fuse Power Density AEB36: 5.34 W/in , AEB45: 3.81 W/in , 3 3 AEB70: 4.92 W/in , AEB100: 4.45 W/in AEB36 T1A/250 VAC, AEB45/70/100 T2A/250 VAC MTBF AEB36: >360 kHrs, AEB45: >300 kHrs, AEB70: >200 kHrs, AEB100: >150 kHrs No Load Input Power <0.5 W to MIL-HDBK-217F at 25 C, GB Output Environmental Output Voltage See tables Operating Temperature AEB36/45/70: 0 C to +60 C derate Initial Set Accuracy 2%, set at 60% load linearly from 100% load at +40 C to 60%, Minimum Load No minimum load required load at +60 C, AEB100: 0 C to +60 C Start Up Delay 3 s max derate linearly from 100% load at +40 C to 50% load at +60 C Start Up Rise Time 20 ms Storage Temperature -20 C to +85 C Hold Up Time AEB36/45/70: 8 ms at 115 VAC Operating Humidity 93% RH, non-condensing AEB100: 20 ms at 115 VAC Drift 0.05% EMC & Safety Line Regulation 1% Emissions EN55022, Level B conducted & radiated Load Regulation See tables Harmonic Currents EN61000-3-2 Class A Ripple & Noise 1% pk-pk max, 20 MHz bandwidth, Voltage Flicker EN61000-3-3 (see note 2) ESD Immunity EN61000-4-2 Level 2 (contact) Perf Criteria A Transient Response 5% max deviation, recovery to within 1% EN61000-4-2 Level 3 (air) Perf Criteria A in 500 s for a 25% load change Radiated Immunity EN61000-4-3, 3 V/m Perf Criteria A Overvoltage Protection Typical 125% max, latching EFT/Burst EN61000-4-4, level 2 Perf Criteria A Overload Protection Trip & restart mode (hiccup mode) Surge EN61000-4-5, installation class 3, Short Circuit Protection Continuous Perf Criteria B Temperature 0.04%/C Conducted Immunity EN61000-4-6, Level 2 Perf Criteria A Coefficient Magnetic Field EN61000-4-8, 3 A/m Perf Criteria A Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals EN62368-1:2014+A11, UL62368-1, China Compulsory Certification (CCC) qualified (AEB36/70 only), CE & UKCA meets all applicable directives & legislation. AC-DCAC-DC AEB36-100 Models and Ratings AEB36 (1) (3) Output Power Output Voltage Output Current Load Regulation Efficiency Model Number 20 W 5.0 V 4.00 A 6% 73% AEB36US05 27 W 9.0 V 3.00 A 5% 77% AEB36US09 30 W 12.0 V 2.50 A 5% 78% AEB36US12 32 W 13.5 V 2.40 A 5% 80% AEB36US13 36 W 15.0 V 2.40 A 3% 80% AEB36US15 36 W 18.0 V 2.00 A 2% 81% AEB36US18 36 W 24.0 V 1.50 A 2% 81% AEB36US24 36 W 48.0 V 0.75 A 2% 83% AEB36US48 Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load). 2. Measured at the output connector with a 0.1 F ceramic capacitor and a 10 F electrolytic capacitor. 3. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. AEB45 (1) (4) (3) Output Power Output Voltage Output Current Load Regulation Efficiency Model Number 45 W 12.0 V 3.75 A 3% 84% AEB45US12 45 W 15.0 V 3.00 A 3% 85% AEB45US15 45 W 18.0 V 2.50 A 2% 85% AEB45US18 45 W 19.0 V 2.37 A 2% 85% AEB45US19 45 W 24.0 V 1.88 A 2% 86% AEB45US24 48 W 48.0 V 1.00 A 2% 87% AEB45US48 Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load). 2. Measured at the output connector with a 0.1 F ceramic capacitor and a 10 F electrolytic capacitor. 3. For optional 500 VAC output to ground isolation add suffix -F to model number. 4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. AEB70 (1) (5) (3) Output Power Output Voltage Output Current Load Regulation Efficiency Model Number 66 W 12.0 V 5.50 A 5% 82% AEB70US12 (4) 69 W 15.0 V 4.60 A 3% 84% AEB70US15 (4) 70 W 18.0 V 3.90 A 2% 84% AEB70US18 (4) 72 W 19.0 V 3.70 A 2% 84% AEB70US19 (4) 72 W 24.0 V 3.00 A 2% 85% AEB70US24 (4) 72 W 48.0 V 1.50 A 2% 87% AEB70US48 Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load). 2. Measured at the output connector with a 0.1 F ceramic capacitor and a 10 F electrolytic capacitor. 3. For optional 500 VAC output to ground isolation add suffix -F to model number. 4. Energy efficiency level V. 5. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. AEB100 (1) (4) (3) Output Power Output Voltage Output Current Load Regulation Efficiency Model Number 100 W 12.0 V 8.34 A 4% 85% AEB100PS12 100 W 12.5 V 8.00 A 4% 85% AEB100PS125 100 W 15.0 V 6.67 A 4% 85% AEB100PS15 100 W 24.0 V 4.17 A 2% 85% AEB100PS24 100 W 48.0 V 2.08 A 2% 85% AEB100PS48 Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load). 2. Measured at the output connector with a 0.1 F ceramic capacitor and a 10 F electrolytic capacitor. 3. For optional 500 VAC output to ground isolation add suffix -F to model number. 4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.