AKM65 Series AC-DC POWER SUPPLIES CONVECTION 65W COOLED The AKM65 series of desktop adaptors comply with medical, home-healthcare and IT approvals along with the latest energy efficiency level VI standards with high active mode efficiency and extremely low no load power consumption. Available with a standard jack plug connector these adaptors suit a wide variety of cost sensitive industrial and medical applications while maintaining industry leading performance. Features Applications IP22 ingress protection IEC/EN60601-1-11 for home healthcare applications Energy efficiency level VI & EU2019/1782 Medical (2 x MOPP) and ITE approvals Healthcare Industrial Medical Technology Electronics Diagnostic Class I & class II versions Input voltage range 80 to 264VAC Dimensions Output voltages from 12V to 48V 4.92 x 2.45 x 1.34 (125.0 x 62.3 x 34.0mm) 0C to +60C operating temperature 3 years warranty Models & Ratings (3)(4) (1) (2) Model Number Output Power Output Voltage Output Current Total Regulation Efficiency AKM65US12 12.0V 5.42A 5% 90.1% AKM65US15 15.0V 4.30A 5% 90.9% AKM65US18 65W 18.0V 3.60A 5% 90.7% AKM65US24 24.0V 2.70A 5% 90.5% AKM65US48 48.0V 1.35A 5% 89.6% Notes: 1. Total regulation includes initial set accuracy, line and load regulation. 2. Typical average value measured at 25%, 50%, 75% and 100% at 230VAC. 3. For white case version add suffix -W e.g. AKM65US12-W. MOQ applies, contact sales for details. 4. Model number shown in the table is for Class I version. For Class II version add suffix C2, e.g. AKM65US24C2. AC-DC POWER SUPPLIES AKM65 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 80 264 VAC Input Frequency 47 63 Hz Input Current 2.0 A 90VAC Inrush Current 100 A 230VAC, cold start at 25C No Load Input Power 150 mW Input Protection Internal fuse in both line and neutral Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 V See Models and Ratings table Minimum Load 0 A No minimum load required Start Up Delay 4 s Start Up Rise Time 30 55 ms Hold Up Time 10 ms Full load and 100VAC Total Regulation 5 % See Models and Ratings table Recovery within <1% within 500s for a 60% step load Transient Response 4 % deviation change at 0.15A/s Measured with 20MHz bandwidth and 10F electrolytic in Ripple and Noise 200 mV pk-pk parallel with 0.1F ceramic capacitor Overload Protection 130 160 % Short Circuit Protection Continuous, trip and restart (hiccup mode) with auto recovery Temperature Coefficient 0.05 %/C General Characteristic Minimum Typical Maximum Units Notes & Conditions Typical average of efficiencies measured at 25%, 50%, Efficiency 89 % 75% and 100% load and 115VAC input Energy Efficiency Level VI 4000 Input to output, 2 x MOPP Isolation: Input to Output Input to Ground 1500 VAC Class I version only Output to Ground Negative output is connected to ground at class I version. Leakage Current 100 A 264VAC, 60Hz Switching Frequency 24 70 kHz Variable Mean Time Between Failure 250 khrs MIL-HDBK-217F at 25C GB Weight 0.75 (340) lb (g) Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 C Derate from 100% load at 40C to 50% load at 60C Storage Temperature -20 +70 C Cooling Natural convection Operating Humidity 5 90 % RH, non-condensing Operating Altitude 5000 m Shock 1m drop onto concrete on each of 6 axes, non operating Vibration 2g, 0.3 decades/min, 15 mins for each of 3 axes 2