150 Watts xppower.com AML150 Series High Power Density Low Cost Universal Input High Efficiency Extended Operating Temperature Non-standard Connectors Available International Safety Approvals Specification Input General Input Voltage 90-264 VAC Efficiency 88% min at 110 VAC or 240 VAC Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output 1500 VAC Input to Ground Input Current 2.0 A rms at 115 VAC, 1.0 A rms at 230 VAC Switching Frequency 65 kHz - PFC & PWM 3 Inrush Current 60 A at 115 VAC, 120 A at 230 VAC, Power Density 5.1 W/In cold start 25 C MTBF >100 kHrs per MIL-HDBK-217F (25 C Power Factor 0.95 typical ambient at full load) Earth Leakage Current 150 A max at 115 VAC, Environmental 250 A max at 230 VAC Input Protection Internal 4 A fuse Operating Temperature 0 C to +70 C, derate from 100% power Standby Power <1 W at 40 C to 60% power at 70 C Consumption Operating Humidity 10 to 95% RH, non-condensing Storage Temperature -20 C to +80 C Output Operating Altitude 3000 m Output Voltage See table Shock 30 G, 10 ms on 3 axis 2 Output Voltage Trim Not user-adjustable Vibration 5-100 Hz, 2.31 m/s , 20 mins, 3 axis Initial Set Accuracy 2 % EMC & Safety Minimum Load No minimum load required Start Up Delay 5 s max at 100 VAC Emissions EN55022/FCC/VCCI, Class B conducted Hold Up Time 3 ms minimum at 100 VAC EN55022/FCC/VCCI, Class B radiated Harmonic Currents EN61000-3-2 Class D Line Regulation 0.5% maximum Load Regulation See table Voltage Flicker EN61000-3-3 Transient Response 4% max. deviation, recovery to within ESD Immunity EN61000-4-2, level 2 Perf Criteria A 1% in 500 s for a 25% load change Radiated Immunity EN61000-4-3, level 2 Perf Criteria A Ripple & Noise 2% max pk-pk (see note 1) EFT/Burst EN61000-4-4, level 2 Perf Criteria A Overvoltage Protection 110-140% Vnom, recycle input to reset Surge EN61000-4-5, level 3 Perf Criteria A Overtemperature Unit shuts down, recycle input to reset Conducted Immunity EN61000-4-6, level 2 Perf Criteria A Protection Dips & Interruptions EN61000-4-11, 30% for 10 ms, Overload Protection 110-150%, auto recovery 60% 100 ms, 100% 5000 ms, Short Circuit Protection Trip and restart (Hiccup mode) Perf Criteria A, B, B Safety Approvals EN60950, UL60950, CSA22.2 No. 60950 Temperature 0.04% /C Coefficient per cUL, CE Mark AC-DCAC-DC AML150 Models and Ratings Output Output Output Model (2) Total Regulation Power Voltage Current Number 150 W 12 V 12.50 A 5% AML150PS12 150 W 15 V 10.00 A 5% AML150PS15 150 W 19 V 7.89 A 5% AML150PS19 150 W 20 V 7.50 A 5% AML150PS20 150 W 24 V 6.25 A 5% AML150PS24 Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 F tantalum and 0.1 F ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. Mechanical Details 4 Cable length approx 70.9 1.97 (1800mm 50mm) 1 3 2 4 1.57 Power On Indicator (40.0) Pin Function 1 Output+ Rubber foot 2 Output+ (4 places.) 3 Return 4 Return Shell Return 2.83 (72.0) 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 1.76 lb (800 g). AC Input 3. Optional output connectors available. Consult sales. IEC 320/C14 Inlet 4. AML150PS12 cable length is 37.4 (950 mm). 5. Output connector mates with Kycon KJP-4S or equivalent. 09-Mar-06 0.02 (0.5) 6.73 (171.0)