AC-DC Power Supplies CMP250 Series 250/500 Watts Peak 250 W Convection-cooled Rating 500 W Peak Power IT & Medical Safety (BF) Approvals U Channel 4x 7.5 Package 80 VAC to 300 VAC Input 5 V/1.5A Standby & 12 V/0.6 A Auxiliary AC OK Signal, Inhibit Current Share 3 Year Warranty Dimensions: The universal AC input CMP250 provides up to 500 W peak power and 250 W convection-cooled in a CMP250: 7.5 x 4 package, over the temperature range -40 C to +50 C with derating to +70 C. Approved for 7.50 x 4.00 x 1.57 (190.5 x 101.6 x 39.9 mm) IT and Medical (BF) applications and with a feature set including constant current overload CMP250-C: characteristics, a 5 V/1.5 A standby output, 12 V/0.6 A auxiliary, AC OK signal, inhibit, current share the 7.89 x 4.12 x 1.92 (200.5 x 104.6 x 48.8 mm) CMP250 is ideal for motors and other electromechanical loads, without the need for fan cooling, in both industrial and medical applications. Models & Ratings Output Current V1 Output Power Standby Supply Aux. Supply (1) Output Voltage V1 Model Number V2 V3 (2) Convection Peak Convection Peak 24 V 10.4 A 20.8 A 5.0 V / 1.5 A 12.0 V / 0.6 A 250 W 500 W CMP250PS24 36 V 6.9 A 13.8 A 5.0 V / 1.5 A 12.0 V / 0.6 A 250 W 500 W CMP250PS36 48 V 5.2 A 10.4 A 5.0 V / 1.5 A 12.0 V / 0.6 A 250 W 500 W CMP250PS48 Notes 1. Add suffix -C for covered version, e.g. CMP250PS24-C (20% derating applies) 2. Peak current/power available for up to 1 minute. Average power must not exceed 225 W, other peak and average load conditions can be accommodated limited by the thermal considerations and average power rating. Peak power and average power derate below 90 VAC. Summary Characteristic Minimum Typical Maximum Units Notes & Conditions 80 115/230 264 Derate output power <90 VAC, see fig.1 Input Range VAC 300 0.5 seconds max No Load Input Power 1.3 W All models, when optional inhibit activated Input Frequency 47 50/60 63 Hz EN61000-3-2 class A compliant Power Factor >0.95 EN61000-3-2 class C for loads 50% Input Current - Full Load 5.2/2.6 A 115/230 VAC. 500 W Inrush Current 30 40 A Cold start 25 C, 230 VAC Earth Leakage Current 100/200 250 A Typ. 115/230 VAC 50 Hz, Max 264 VAC 60 Hz Patient Leakage Current 55 80 A Efficiency 89 % 230 VAC, 250 W See derating curve, fig.8 and Thermal Considerations on Operating Temperature -40 +70 C page 8 EMC EN55032/11 Class B Conducted & Radiated, EN61000-3-2, EN61000-3-3 EN62368-1, UL62368-1, CSA C22.2 No. 62368-1, IEC62368-1, IEC60950-1 Ed 2, IEC60601-1 Ed 3 Including Risk Management, Safety Approvals ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:14 www.xppower.com 1AC-DC Power Supplies CMP250 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 80 115/230 264 VAC Derate output power < 90 VAC. See fig. 1 Input Voltage - Fault Condition 300 VAC 0.5 seconds max Input Frequency 47 50/60 63 Hz EN61000-3-2 class A compliant Power Factor >0.95 EN61000-3-2 class C for loads 50% Input Current - Full Load 5.2/2.6 A 115/230 VAC. 500 W 1.3 All models, when optional inhibit activated 7.8 CMP250PS24 - 115V AC 6.4 CMP250PS24 - 230V AC No Load Input Power 6.5 W CMP250PS36 - 115V AC 4.2 CMP250PS36 - 230V AC 7.0 CMP250PS48 - 115V AC 6.0 CMP250PS48 - 230V AC Inrush Current 30 40 A 230 VAC Earth Leakage Current 100/200 250 A Typ. 115/230 VAC 50 Hz, Max 264 VAC 60 Hz Input Protection F10 A/250 V internal fuse in both AC lines Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 24 48 VDC See Models and Ratings table Initial Set Accuracy 1 % 50% load, 115/230 VAC Output Voltage Adjustment 10 % Minimum Load 0A Start Up Delay 1.0 2.0 s 115/230 VAC full load from input AC turn on Hold Up Time 20 ms 90 VAC, 250 W Drift 0.2 % After 20 min warm up Line Regulation 0.5 % Load Regulation 1.0 % 0-100% load Recovery within 1% in less than 500 s Transient Response <4 % for a 50-75%-50% load change Ripple & Noise 1 % pk-pk 20 MHz bandwidth Overvoltage Protection 115 140 % Vnom DC. Output 1, recycle input to reset Overload Protection 205 255 % Of average power, approx. constant current Short Circuit Protection Continuous, no damage Temperature Coefficient 0.05 %/C Overtemperature Protection Shut down & auto recovery Patient Leakage Current 55 80 A Input Voltage Derating Figure 1 500 Peak Power for 1 minute 450 400 275 250 Convection power 225 Average power 200 175 150 90 80 85 264 300 Input Voltage (VAC) www.xppower.com 2 Average Output Power (W) 0.5 Seconds Maximum