10 15 Watts xppower.com CU10 15 Series Low Cost Small Size PCB Mount 15 Watt Medical Version Single Output 3.3 24 V Peak Load Capability Non standard Outputs Available Specification Input General Input Voltage 85-264 VAC (120-370 VDC) Efficiency See tables Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output (CU10/15) 4000 VAC Input to Output (CU15-M) Input Current 0.13 A rms at 230 VAC (CU10) 0.20 A rms at 230 VAC (CU15) Switching Frequency 100 kHz typical for 10 W models 67 kHz typical for 15 W models Inrush Current 20 A at 115 VAC, 40 A at 230 VAC, 3 3 cold start 25 C Power Density 2.43 W/in (CU10) 3.17 W/in (CU15) Earth Leakage Current Class 2 (no earth) MTBF >500 kHrs per MIL-HDBK-217F (15 & 24 V units >400 kHrs) Input Protection 1A fuse (CU10) 2A fuse (CU15, CU15-M) Environmental Output Operating Temperature CU10/15: 0 C to +65 C, derate from full load at +45 C to no load at +65 C Output Voltage See table CU15-M: 0 C to +70 C, derate from Output Voltage Trim 5% full load at +50 C to 50% load at +70 C Initial Set Accuracy 1% Cooling Convection-cooled Minimum Load No minimum load required Operating Humidity 95% RH, non-condensing Start Up Delay 1.5 s max Storage Temperature -20 C to +85 C Start Up Rise Time 14 ms max Operating Altitude 3000 m Hold Up Time 16 ms typical at full load and 115 VAC Vibration 10 Hz to 500 Hz, 2 g for 10 mins/cycle Drift 0.6% 60 min each cycle Line Regulation 0.5% max Load Regulation 1.0% max 10% load to full load EMC & Safety Transient Response 4% max deviation, recovery to within 1% Emissions CU15-M: EN55011 Level B conducted within 500 s for 25% load change Others: FCC20780 Level B, Ripple & Noise 1% max pk-pk (see note 1) EN55022 Class B conducted Overvoltage Protection 130-150% of Vnom, recycle input to reset ESD Immunity EN61000-4-2, level 3, Perf Criteria A Short Circuit Protection Trip and restart (Hiccup mode) Radiated Immunity EN61000-4-3, level 3, Perf Criteria A Temperature 0.05%/ C EFT/Burst EN61000-4-4, level 2, Perf Criteria A Coefficient Surge EN61000-4-5, level 3, Perf Criteria A Conducted Immunity EN61000-4-6, 10 V, Perf Criteria A Dips & interruptions EN61000-4-11, 30% 10 ms, 60% 1000 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals CU15-M: EN60601, UL2601-1, CSA22.2 No. 601.1 per cUL Others: EN60950, UL1950, CSA22.2 No. 234 per cUL 1 AC DCAC DC CU10 15 Models and Ratings Output Current Output Output Efficiency Model (3) (2) Power Voltage (typical) Number Nominal Peak 8.25 W 3.3 VDC 2.50 A 3.80 A 65% CU10-00 5.0 VDC 2.00 A 2.80 A 70% CU10-10 9.0 VDC 1.12 A 1.50 A 72% CU10-09 10 W 12.0 VDC 0.84 A 1.20 A 75% CU10-12 15.0 VDC 0.67 A 1.00 A 75% CU10-13 24.0 VDC 0.42 A 0.65 A 78% CU10-14 Output Current Output Output Efficiency Model (3) (4) (2) (typical) Number Power Voltage Nominal Peak 10 W 3.3 VDC 3.00 A 4.50 A 70% CU15-00 5.0 VDC 3.00 A 4.50 A 73% CU15-10 9.0 VDC 1.67 A 3.00 A 75% CU15-09 15 W 12.0 VDC 1.25 A 1.80 A 80% CU15-12 15.0 VDC 1.00 A 1.50 A 80% CU15-13 24.0 VDC 0.63 A 0.95 A 82% CU15-14 Notes 1. Measured at 20 MHz bandwidth. 3.3 V models are 50 mV maximum. 3. Alternative output voltages available. Consult sales. 2. Peak load lasting <30 s with a maximum duty cycle of 10%. 4. Medical approved 15 W version available. Add suffix -M to part number. Mechanical Details CU10 models CU15/CU15-M models 0.07 (1.78) 0.07 (1.78) 0.04 (1.02) 0.15 (3.8) 0.15 (3.8) **Note: CU15-M models 0.04 (1.02) height 0.99 (25.2) -Vo -Vo N N +Vo +Vo L L 0.22 (5.5) 2.126 (54.0) 0.157 (4.0) 2.441 (62.0) 2.56 (65.02) 2.75 (69.9) weight: 0.132 lb (60 g) weight: 0.176 lb (80 g) Notes 1. All dimensions shown in inches (mm). 2. For mating connectors only, order part number CU20-60 CONKIT 20-Apr-07 1.77 (45.0) 0.885 (22.5) 0.196 (5.0) 0.91 (23.0) 0.491 (12.47) 1.28 (32.48) 1.89 (48.0) 0.945 (24.0) 0.91 (23.0)** 0.157 (4.0) 0.492 (12.50) 1.398 (35.51)