xppower.com 175 300 Watts HUL Series Compact Size, Low Profile 3 Up to 5.85 W/in Power Density Single & Multiple Outputs Convection cooled Ratings Remote On/Off Power Fail Detect 12 V Fan Supply Specification Input General Input Voltage 90-132 VAC, 180-264 VAC (auto-ranging) Efficiency 80% typical Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output, 1500 VAC Input to Ground, Input Current HUL175: 4.4 A max at 115 VAC, 500 VAC Output to Ground 2.2 A max at 230 VAC HUL200: 5.0 A max at 115 VAC, Switching Frequency 42 kHz typical 3 3 2.5 A max at 230 VAC Power Density HUL175: 4.51 W/In , HUL200: 5.85 W/In , 3 HUL300: 6.3 A max at 115 VAC, HUL300: 4.41 W/In 3.15 A max at 230 VAC Power Fail Detect On = Logic high 100-500 ms after outputs Inrush Current 35 A at 115 VAC, 70 A max at 264 VAC with regulation +25 C cold start Fail = Logic low at least 1 ms prior to loss Power Factor Passive PFC, meets EN6100-3-2, -3 of output Earth Leakage Current <1.5 mA at 230 VAC / 50 Hz MTBF 100 kHrs per MIL-HDBK-217F Output Environmental Output Voltage See tables Operating Temperature 0 C to +60 C, derate linearly from 100% Output Voltage Trim 5% on output 1 at +40 C to 50% at +60 C Initial Set Accuracy 1% max for single/main output Cooling See notes 5% for auxiliary outputs Operating Humidity 5-90% RH, non-condensing Minimum Load See tables & note 1 for 175 W model Storage Temperature -20 C to +85 C Start Up Delay 1 s max Operating Altitude 3000 m Start Up Rise Time 20 ms max Shock 15 g (non-operation), 11 ms (half sine Hold Up Time >15 ms at 115 VAC wave), 3 times for each axis Total Regulation 1% max for single output models, Vibration 10-55 Hz (non-operation) 2 g, sweep time 5% max for multiple output models 3 mins, 60 mins/axis Over/Undershoot <5% max Transient Response 5% max deviation, recovery to within EMC & Safety 1% in 500 s for a 50% load change Emissions EN55022 and FCC, level B Ripple & Noise 1% pk-pk (50 mV max for 3.3 V output) (level A - 300 W) conducted Overvoltage Protection 130% on output 1 only, recycle input to Harmonic Currents EN61000-3-2 reset Voltage Flicker EN61000-3-3 Overtemperature Shuts down when ambient temperature ESD Immunity EN61000-4-2, level 4 Perf Criteria A Protection exceeds +85 C, auto recovery Radiated Immunity EN61000-4-3, level 3 Perf Criteria A Overload Protection 110-135% of total power, auto recovery EFT/Burst EN61000-4-4, level 3 Perf Criteria A Short Circuit Protection Trip and restart (Hiccup mode) Surge EN61000-4-5, level 3 Perf Criteria A Temperature 0.1%/C Conducted Immunity EN61000-4-6, 10 V Perf Criteria A Coefficient Dips & Interruptions EN61000-4-11, 30% 10 ms, Remote Sense HUL175 only. Compensates for 0.5 V drop 70% 100 ms, 95% 5000 ms, on 3.3 V output Perf Criteria A, B, B Remote On/Off On = Logic High or Open Safety Approvals EN60950, UL60950, CSA22.2 No. 950 Off = Logic Low or Short per cUL, CE Mark Not available on HUL175 Fan Output 12 V, 300 mA AC DCAC DC HUL175 Models and Ratings Output 1 Output 2 Output 3 Output 4 Model Voltage Conv Max Voltage Conv Max Voltage Conv Max Voltage Conv Max Number Nom Cooled 18.7 CFM Nom Cooled 18.7 CFM Nom Cooled 18.7 CFM Nom Cooled 18.7 CFM 5.0 V 10.0 A 15.0 A 3.3 V 10.0 A 20.0 A 12.0 V 2.2 A 3.0 A -5.0 V 0.7 A 1.0 A HUL175-40-3 5.0 V 10.0 A 15.0 A 3.3 V 10.0 A 20.0 A 12.0 V 2.2 A 3.0 A -12.0 V 0.7 A 1.0 A HUL175-42-3 5.0 V 10.0 A 15.0 A 3.3 V 10.0 A 20.0 A 24.0 V 1.5 A 2.0 A -12.0 V 0.7 A 1.0 A HUL175-45-3 5.0 V 10.0 A 15.0 A 3.3 V 10.0 A 20.0 A 15.0 V 2.2 A 3.0 A -15.0 V 0.7 A 1.0 A HUL175-46-3 Notes 1. Minimum load is 2.0 A for V1, 0.0 A for V2 & V4, and 0.3 A for V3. 2. Total regulation for V1, V2 and V3 = 5% V4 = 3%. Total regulation includes tolerance, line regulation and load regulation. 3. Total combined output power for the 3.3 V and 5.0 V not to exceed 126 W with 18.7 CFM or 70 W with convection cooling. 4. Maximum load continuous output power is 175 W with minimum 18.7 CFM forced air cooling or 100 W with convection cooling. 5. Outputs are fully isolated. Available from Farnell. See pages 204-206. Mechanical Details All dimensions are in inches (mm). Tolerance: 0.02 (0.5) max. Weight: 1.32 lbs (600 g) approx. 0.65 0.2 (16.5) (5.1) B M3 x 0.5 STAND OFF 4 PLACES 2 P2 1 A M4 x 0.7 NUT FASTENER 8 PLACES 24 3.80 P1 (96.5) G N P3 2.50 L (63.5) 1 P2 Connector A Pin Function 1 Fan + 2 Fan - B 6.40 (162.5) P3 Connector Pin Function 1 +3.3 V Sense+ 4.58 (116.3) 2, 14 Output 2 2.90 (73.7) 3, 15 Output 2 0.80 4, 16 Return (20.3) 5, 17 Return 6, 18 Return A A 7, 19 Output 1 1.50 8, 20 Output 1 1.25 (38.1) 9, 21 Output 3 (31.8) 10, 22 Return 11,23 Output 4 12 Power Fail Detect 5.20 (132.1) 0.24 13 +3.3 V Sense- 6.00 (152.4) (6.00) 24 Return 6.80 (172.7) Notes 1. Input connector P1 mates with Molex housing 09-91-0500 and Molex 2478/2578/8818 series crimp terminal. 2. Output connector P3 mates with Molex housing 39-01-2240 and Molex 44476 series crimp terminal. 3. Fan connector P2 mates with JST housing XHP-2 and JST SXH-002T-P0.6 crimp terminals. Fan output is 12 V/160 mA. 4. Covered versions are available, add suffix: -C to model number for cover only, dimensions: 3.80 x 6.80 x 1.66 (96.5 x 172.7 x 42.1 mm), add suffix: -FC to model number for fan cover, dimensions: 3.80 x 6.80 x 2.48 (96.5 x 172.7 x 63.0 mm). 5. Cable harnesses with 11.81 (300 mm) wire available, order part HUL175 LOOM KIT. For mating connectors only, order part HUL175 CONN KIT. 6. Covers are available separately. Order part HUL175 COVER or HUL175 F/COVER for Fan Cover. 7. Max penetration of screws 0.12 (3.0 mm).