xppower.com 120 Watts AML120 Series Energy Star Level V 18 V CEC 2008 & EISA 2007 Compliant 15V High Power Density Single Outputs from 15 V to 48 V High Efficiency 0 C to +70 C Operating Temperature Non standard Connectors Available Specification Input General Input Voltage 90-264 VAC Efficiency 87% typical, 80% min for 15 V models Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output Input Current 1.6 A rms at 115 VAC, 1500 VAC Input to Ground 0.8 A rms at 230 VAC Output 0 V is electrically connected to Inrush Current 60 A at 115 VAC, 120 A at 230 VAC, Input Ground cold start +25 C Switching Frequency 20-110 kHz variable Power Factor 0.98 typical at 115 VAC 3 Power Density 4.9 W/In Earth Leakage Current 150 A max at 115 VAC, 60 Hz MTBF >100 kHrs per MIL-HDBK-217F 250 A max at 230 VAC, 50 Hz Input Protection Internal 3 A fuse Environmental Standby Power <0.5 W Consumption Operating Temperature 0 C to +70 C, derate from 100% power at +50 C to 60% power at +70 C Cooling Convection-cooled Operating Humidity 10-95% RH, non-condensing Output Storage Temperature -20 C to +80 C Output Voltage 15 to 48 VDC Operating Altitude 3000 m Output Voltage Trim Not user-adjustable Shock 30 g, 10 ms on 3 axes Initial Set Accuracy 2% 2 Vibration 5-100 Hz, 2.31 m/s , 20 mins, 3 axes Minimum Load No minimum load required Start Up Delay 2 s max at 115 VAC EMC & Safety Start Up Rise Time <80 ms at 115 VAC Emissions EN55022/FCC/VCCI, Class B conducted Hold Up Time 15 ms minimum at full load and 115 VAC EN55022/FCC/VCCI, Class B radiated Line Regulation 0.5% maximum Harmonic Currents EN61000-3-2 Load Regulation See table Voltage Flicker EN61000-3-3 Transient Response 4% max. deviation, recovery to within ESD Immunity EN61000-4-2, level 3 Perf Criteria A 1% in 500 s for a 25% load change Radiated Immunity EN61000-4-3, level 3 Perf Criteria A Ripple & Noise 2% max pk-pk (see note 1) EFT/Burst EN61000-4-4, level 2 Perf Criteria A Overvoltage Protection 110-140% Vnom, recycle input to reset Surge EN61000-4-5, level 3 Perf Criteria A Overtemperature Unit shuts down, recycle input to reset Conducted Immunity EN61000-4-6, 10 V Perf Criteria A Protection Dips & Interruptions EN61000-4-11, 30% for 10 ms, Overload Protection 110-150%, auto recovery 60% 100 ms, 100% 5000 ms, Short Circuit Protection Trip and restart (Hiccup mode) Perf Criteria A, B, B Temperature 0.04%/C Safety Approvals EN60950, UL60950, Coefficient CSA22.2 No. 60950 per cUL, CE Mark AC DCAC DC AML120 Models and Ratings Output Output Output Total Model (2) Power Voltage Current Reguaion Number 105 W 15 V 7.00 A 5% AML120PS15 120 W 18 V 6.67 A 5% AML120PS18 120 W 19 V 6.32 A 5% AML120PS19 120 W 20 V 6.00 A 5% AML120PS20 120 W 24 V 5.00 A 5% AML120PS24 120 W 30 V 4.00 A 5% AML120PS30 120 W 36 V 3.34 A 5% AML120PS36 120 W 48 V 2.50 A 5% AML120PS48 Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 F tantalum and 0.1 F ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. Mechanical Details Cable length approx 71 (1800mm) 1 3 2 4 1.46 Power On Indicator (37.0) Pin Function 1 Return/Input Earth Rubber foot 2 Output + (4 places.) 3 Return/Input Earth 4 Output + Shell Return/Input Earth 2.56 (65.0) AC Input IEC 320-C6 Inlet (Mates with a C5 plug) Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Maximum load per pin on output connector is 5 A. 3. Optional output connectors available. Consult sales. 4. Output connector is non locking 4 pin DC power plug and mates with Kycon part KPJ-4S or equivalent. 24-Oct-13 0.02 (0.5) 6.58 (167.0)