150 Watts xppower.com AML150 Series High Power Density Single Outputs from 12 V to 24 V Universal Input High Efficiency 0 C to +70 C Operating Temperature Non-standard Connectors Available International Safety Approvals Specification Input General Input Voltage 90-264 VAC Efficiency 88% min Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output 1500 VAC Input to Ground Input Current 2.0 A rms at 115 VAC, Output 0 V is electrically connected to 1.0 A rms at 230 VAC Input Ground Inrush Current 60 A at 115 VAC, 120 A at 230 VAC, Switching Frequency 20-80 kHz variable cold start +25 C 3 Power Density 5.1 W/In Power Factor 0.95 typical MTBF >100 kHrs per MIL-HDBK-217F Earth Leakage Current 150 A max at 115 VAC, (+25 C ambient at full load) 250 A max at 230 VAC Input Protection Internal 4 A fuse Environmental Standby Power <1 W Consumption Operating Temperature 0 C to +70 C, derate from 100% power at +40 C to 60% power at +70 C Output Operating Humidity 10-95% RH, non-condensing Storage Temperature -20 C to +80 C Output Voltage See table Operating Altitude 3000 m Output Voltage Trim Not user-adjustable Shock 30 g, 10 ms on 3 axes Initial Set Accuracy 2% 2 Vibration 5-100 Hz, 2.31 m/s , 20 mins, 3 axes Minimum Load No minimum load required Start Up Delay 5 s max at 100 VAC EMC & Safety Hold Up Time 3 ms minimum at 100 VAC Emissions EN55022/FCC/VCCI, Class B conducted Line Regulation 0.5% maximum EN55022/FCC/VCCI, Class B radiated Load Regulation See table Harmonic Currents EN61000-3-2 Transient Response 4% max. deviation, recovery to within Voltage Flicker EN61000-3-3 1% in 500 s for a 25% load change ESD Immunity EN61000-4-2, level 2 Perf Criteria A Ripple & Noise 2% max pk-pk (see note 1) Radiated Immunity EN61000-4-3, level 2 Perf Criteria A Overvoltage Protection 110-140% Vnom, recycle input to reset EFT/Burst EN61000-4-4, level 2 Perf Criteria A Overtemperature Unit shuts down, recycle input to reset Protection Surge EN61000-4-5, level 3 Perf Criteria A Conducted Immunity EN61000-4-6, level 2 Perf Criteria A Overload Protection 110-150%, auto recovery Short Circuit Protection Trip and restart (Hiccup mode) Dips & Interruptions EN61000-4-11, 30% for 10 ms, 60% 100 ms, 100% 5000 ms, Temperature 0.04%/C Perf Criteria A, B, B Coefficient Safety Approvals EN60950, UL60950, CSA22.2 No. 60950 per cUL, CE Mark AC-DCAC-DC AML150 Models and Ratings Output Output Output Model (2) Total Regulation Power Voltage Current Number 150 W 12 V 12.50 A 5% AML150PS12 150 W 15 V 10.00 A 5% AML150PS15 150 W 19 V 7.89 A 5% AML150PS19 150 W 20 V 7.50 A 5% AML150PS20 150 W 24 V 6.25 A 5% AML150PS24 Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 47 F tantalum and 0.1 F ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. Available from Farnell. See pages 204-206. Available from Newark. See page 207-208. Mechanical Details (4) Cable length approx 70.9 1.97 (1800mm 50mm) 3 1 2 4 1.57 Power On Indicator (40.0) Pin Function Rubber foot 1 Output + (4 places.) 2 Output + 3 Return/Input Earth 4 Return/Input Earth Shell Return/Input Earth 2.83 (72.0) AC Input IEC 320/C14 Inlet Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 1.76 lb (800 g). 3. Optional output connectors available. Consult sales. 4. AML150PS12 cable length is 37.4 (950 mm). 5. Output connector (Kycon KPP-4P or equivalent) mates with Kycon KPJ-4S or equivalent. 17-Apr-07 0.02 (0.5) 6.73 (171.0)