50-150 Watts xppower.com DLG Series AC Input LED Driver Constant Voltage & Current Operation High Power Factor High Efficiency Water Proof to IP67 90-305 VAC Input Voltage Range 3 Year Warranty Specification Input General Input Voltage 90-305 VAC, see derating curve Efficiency See table Input Frequency 47-63 Hz Isolation 3750 VAC Input to Output 1880 VAC Input to Ground Input Current 50 W: 1.0 A at 115 VAC, 0.5 A at 230 VAC, 500 VAC Output to Ground 75 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC, 100 W: 1.4 A at 115 VAC, 0.7 A at 230 VAC, Switching Frequency DLG50/75: 40-80 kHz 150 W: 2.0 A at 115 VAC, 1.0 A at 230 VAC DLG100/150: PWM 60-80 kHz, PFC 55-133 kHz Inrush Current 65 A at 230 VAC, cold start +25 C MTBF >200 kHrs to MIL-HDBK-217F at 25 C, GB Power Factor >0.94 at 230 VAC, full load Earth Leakage Current DLG50/75: 500 A max at 230 VAC Environmental DLG100/150: 750 A max at 230 VAC No Load Input Power DLG100: 0.5 W max at 230 VAC Operating Temperature DLG50/75: -40 C to +60 C Other models: 0.6 W max at 230 VAC (see derating curve), Input Protection DLG50/75 T2.5A/300V fuse fitted in line, DLG100/150: -30 C to +70 C DLG100 T3.15A/300V fuse fitted in line, (see derating curve) DLG150 T4A/300V fuse fitted in line Operating Humidity 5-100% RH, non-condensing Storage Temperature -40 C to +80 C Operating Altitude 3000 m Output Vibration 10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in Output Voltage See table each of 3 axes Minimum Load No minimum load required Start Up Delay 1.5 s max at 115 VAC EMC & Safety Hold Up Time DLG50/75: No hold up Emissions EN55015, class B conducted and radiated DLG100/150: 16 ms minimum Harmonic Currents EN61000-3-2, class A Line Regulation 0.5% EN61000-3-2, class C for loads >80% Load Regulation 1.0% in constant voltage mode, Voltage Flicker EN61000-3-3 5.0% in constant current mode ESD Immunity EN61000-4-2, 8 kV air and 4 kV contact, Turn On Overshoot 5% max Perf Criteria A Transient Response 5% maximum deviation, recovery to within Radiated Immunity EN61000-4-3, level 2 Perf Criteria A 1% in 10 ms for a 50% load change (1) EFT/Burst EN61000-4-4, level 2 Perf Criteria A Ripple & Noise DLG50/75 Surge EN61000-4-5, installation class 3, DLG100/150: 150 mV pk-pk up to 36 V Perf Criteria A output, 200 mV for 48 V output, 240 mV for 54 V output (see note 2) Conducted Immunity EN61000-4-6, level 2 Perf Criteria A Overvoltage Protection 110-142%, recycle mains to reset, only on Dips & Interruptions EN61000-4-11, 30% 10 ms, DLG100 & DLG150 versions 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Overtemperature Unit shuts down, recycle mains to reset Protection Safety Approvals EN61347, UL8750, CE Mark Overload Protection 105% maximum, auto recovery Short Circuit Protection Trip and restart (hiccup mode) Temp. Coefficient 0.04%/C Notes 1. DLG50/75 use a topology which results in increased levels of mains frequency related ripple. Contact technical sales for details. AC-DCAC-DC DLG50-150 Models and Ratings Output Voltage (1) Output Power Output Voltage Output Current Range in Constant Efficiency Model Number Current Mode 50 W 12.0 V 4.20 A 8.5-12.0 V 84.0% DLG50PS12 50 W 24.0 V 2.10 A 19.0-24.0 V 86.0% DLG50PS24 50 W 36.0 V 1.40 A 26.0-36.0 V 88.0% DLG50PS36 50 W 48.0 V 1.05 A 35.0-48.0 V 88.0% DLG50PS48 59 W 12.0 V 4.90 A 8.5-12.0 V 84.0% DLG75PS12 75 W 24.0 V 3.15 A 19.0-24.0 V 86.0% DLG75PS24 74 W 30.0 V 2.45 A 22.0-30.0 V 87.0% DLG75PS30 75 W 36.0 V 2.10 A 26.0-36.0 V 88.0% DLG75PS36 67 W 48.0 V 1.40 A 35.0-48.0 V 88.0% DLG75PS48 75 W 54.0 V 1.40 A 37.0-54.0 V 88.0% DLG75PS54 100 W 12.0 V 8.30 A 9.0-12.0 V 88.0% DLG100PS12 (3) 100 W 15.0 V 6.60 A 10.0-15.0 V 88.0% DLG100PS15 100 W 24.0 V 4.20 A 14.0-24.0 V 90.0% DLG100PS24 100 W 30.0 V 3.30 A 22.0-30.0 V 90.0% DLG100PS30 100 W 36.0 V 2.80 A 26.0-36.0 V 90.0% DLG100PS36 100 W 48.0 V 2.10 A 34.0-48.0 V 90.5% DLG100PS48 (3) 100 W 57.0 V 1.75 A 43.0-57.0 V 90.5% DLG100PS57 132 W 12.0 V 11.00 A 9.0-12.0 V 88.0% DLG150PS12 (3) 150 W 15.0 V 10.00 A 11.0-15.0 V 88.0% DLG150PS15 150 W 24.0 V 6.30 A 14.0-24.0 V 90.0% DLG150PS24 150 W 30.0 V 5.00 A 22.0-30.0 V 90.0% DLG150PS30 150 W 36.0 V 4.20 A 26.0-36.0 V 90.0% DLG150PS36 150 W 48.0 V 3.20 A 33.0-48.0 V 90.0% DLG150PS48 (3) 150 W 54.0 V 2.80 A 38.0-54.0 V 90.0% DLG150PS54 Notes 1. Typical efficiency at full load and 230 VAC input. 3. Not UL8750 approved. 2. Measured using 12 twisted pair with 0.1 F and 47 F capacitors in parallel at 20 MHz bandwidth. Mechanical Details A B 0.28 (7.0) 2.68 (68.0) C 0.35 (8.9) DLG50/75 DLG100/150 4-R2.1 AC IN DC OUT ACL A 6.93 (176.0) 8.74 (222.0) 1.35 (34.2) V+ (RED) ACN V- (BLACK) B 6.38 (162.0) 8.19 (208.0) 18 AWGx2C (DLG50/75/100- 18AWGx3C C 6.03 (153.2) 7.83 (199.0) see note 4 below) 14 AWGx2C (DLG150) 0.35 (8.9) Notes 11.810.79 (30020) 11.810.79 (30020) 1. All dimensions shown in inches (mm). 2. Weight: DLG50/75: 1.98 lbs (900 g) 1.54 (39.0) DLG100/150 2.29 lbs (1040 g) 3. Tolerance: 0.02 (0.5) 4. DLG100PS12 and DLG100PS15 output cable is 14 AWG. Application Notes Constant Voltage / Constant Current Curve Vo max Vo min Trip & Restart Zone 0 10 20 30 40 50 60 70 80 90 100 Output Current (%) Derating Curve 100 100 A A B B C 80 80 60 60 C A DLG150 at 115 VAC 40 40 B DLG150 at 230 VAC & DLG100 A DLG50/75 C DLG50/75 B DLG100 20 20 C DLG150 0 0 0 10 20 30 40 50 55 60 70 90 100 115 130 180 220 240 305 Ambient Temp (C) -30 for DLG100/150 Input Voltage (VAC) 60Hz -40 for DLG50/75 Ta= 25C 27 Sept 16 Load (%) Output Voltage Load (%)