xppower.com
120960 Watts
DNR120960TS Series
Three Phase AC Input
Up to 93% Efficiency
Wide Adjustment Range
Full Power 40 C to +60 C
Rugged Design for Industrial Applications
Single Phase Input Operation (340575 VAC)
3 Year Warranty
Specification
Input General
Input Voltage 340-575 VAC 3 phase (single phase Efficiency See table
operation with 75% of rated output),
Isolation 3000 VAC Input to Output, 1500 VAC
480-820 VDC
Input to Ground, 500 VAC Output to
Input Frequency 47-63 Hz Ground
Input Current See tables Switching Frequency DNR120TS: 70 kHz typical,
DNR240TS: 25 kHz typical,
Inrush Current DNR120: 10.0 A, DNR240: 20.0 A,
DNR480TS: 80 kHz typical,
DNR480: 20.0 A, DNR960: 30.0 A,
DNR960TS: 52 kHz typical
typical at 480 VAC, cold start
Signals DC ON indicator LED Green,
Power Factor 0.6 typical at 480 VAC input and nominal
DC LOW indicator LED Red
load, DNR960TS: 0.8 typical at 480 VAC
DC OK: normally open relay on 24 V models
input and nominal load
MTBF DNR120TS: 550 kHrs, 240TS: 500 kHrs
Earth Leakage Current 0.32 mA
480TS: 420 kHrs, 960TS: 380 kHrs to
Input Protection 3 internal fuses,
Bellcore Issue 6, at +40 C, GB
DNR120TS, DNR240TS: T2.0 A, 600 VAC,
DIN Rail Compatible with TS35/7.5 or TS35/15
DNR480TS: T3.15 A, 500 VAC,
DNR960TS: T5.0 A, 500 VAC
Environmental
Output
Operating Temperature -40 C to 70 C (DNR480TS -30 C),
derate linearly from 60 C at 2.5%/C
Output Voltage See table
(3.5%/C for DNR960TS), start up at
Output Voltage Trim See table
-35 C (DNR480TS -20 C)
Initial Set Accuracy 1%
see derating curves
Minimum Load No minimum load required
Cooling Convection-cooled with 25 mm free space
Start Up Delay <1 s (may increase at low
all sides
temperature extremes)
Operating Humidity 20-95% RH, non-condensing
Start Up Rise Time <150 ms
Storage Temperature -40 C to +85 C
Hold Up Time 20 ms min at 480 VAC,
Shock 15 g, 11 ms, 3 axis, 6 faces, 3 shocks/face
DNR960TS: 15 ms min at 480 VAC
Vibration 2 g, 10 Hz to 500 Hz, along X, Y & Z axis,
Line Regulation 1%
60 min/axis, mounted on rail
Load Regulation 1% max (5% for units in parallel (not
DNR120TS))
EMC & Safety
Parallel Operation 2 units can be connected in parallel
Emissions EN55022, Class B conducted & radiated
(not DNR120TS), total power available is
Harmonic Currents EN61000-3-2, Class A
90% of the rated current of each unit,
minimum load per unit 10%, use Ishare Voltage Flicker EN61000-3-3
connection for DNR960TS. Redundancy
ESD Immunity EN61000-4-2, level 4 Perf Criteria A
module DPM10 available for load currents
Radiated Immunity EN61000-4-3, level 3 Perf Criteria A
up to 10 A, contact sales
EFT/Burst EN61000-4-4, level 4 Perf Criteria A
Transient Response 4% max deviation recovering to within
Surge EN61000-4-5, installation class 4,
1% in 2 ms for 50% load change
Perf Criteria A
Ripple & Noise 100 mV pk-pk 20 MHz bandwidth,
Conducted Immunity EN61000-4-6, level 3 perf criteria A
DNR960TS: 80 mV pk-pk 20 MHz
bandwidth, (may increase at low Magnetic Field EN61000-4-8, level 4 perf criteria A
temperature extremes)
Dips & Interruptions EN61000-4-11, 30% 500 ms,
Overvoltage Protection 120-145%, auto recovery 60% 200 ms, >95% 5000 ms
Perf Criteria A, A, A
Overload Protection 110%-140%, constant current,
Safety Approvals EN60950-1 UL508 UL60950-1
auto recovery
Pollution Degree 2,
Temperature Coefficient 0.03%/C
UL60950-1 Overvoltage Category II
Short Circuit Protection Continuous trip and restart (hiccup mode)
UL508 Overvoltage Category III,
(DNR480TS switchable hiccup mode or
ANSI/ISA 12.12.01 Class 1, Division 2,
power limited )
Groups A,B,C and D
ACDCACDC
DNR120960TS
Models and Ratings
Input Current (typ.)
Output Voltage
(1)
Output Voltage Output Current Efficiency (typ.) Model Number
Trim
400 VAC 500 VAC
12 V 0.36 A 0.30 A 11.4-14.5 V 10.0 A 87% DNR120TS12
24 V 0.36 A 0.30 A 22.5-28.5 V 5.0 A 89% DNR120TS24
24 V 0.65 A 0.55 A 22.5-28.5 V 10.0 A 90% DNR240TS24-I
48 V 0.65 A 0.55 A 47.0-56.0 V 5.0 A 91% DNR240TS48-I
24 V 1.10 A 0.93 A 22.5-28.5 V 20.0 A 90% DNR480TS24-I
48 V 1.10 A 0.93 A 47.0-56.0 V 10.0 A 91% DNR480TS48-I
24 V 1.72 A 1.50 A 22.5-28.5 V 40.0 A 92% DNR960TS24-I
48 V 1.72 A 1.50 A 47.0-56.0 V 20.0 A 93% DNR960TS48-I
Notes
1. Reduce by 25% for single phase input operation, (340-575 VAC).
V
Mechanical Details
0.3
5.91 (150.0)
4.39 (111.3)
(7.0)
DC Output Voltage Trim
6 1
+ + --
DC DC
OK OK
DC LO
ON
4.87
(123.6)
DNR120TS DNR240TS DNR480TS
4.87 4.87
Voltage All Units
(123.6) (123.6)
DC LO
Trim
ON Voltage Trim
AC Input DC Output
Parallel
Single
DC DC
L1 L2 L3 L1 L2 L3
L1 L2 L3 +V +V-V -V
+ + -- LO ON
DC OK
5
4 1
1 4 1 4 56
1 44 1 Voltage Adj.
6
AC Input DC Output
AC Input
Single/parallel & current limit
selector switches on underside
2.93 (74.3) 3.50 (89.0)
DC OK signal connector
on underside, Spring type,
2
AWG26-20/0.2-0.5 mm
10.86 (275.7)
Pin Connections - DC Output
DNR120 DNR240-480 DNR960TS
Pin
Designation Designation Designation
1 -V -V DC OK*
2 -V -V DC OK*
4.96
(8)
DNR960TS
(125.9)
3 +V +V +Ishare
Pin Connections - AC Input
(8)
4 +V +V -Ishare
Pin Designation
5 DC OK* DC OK* +V
1 Ground
DC Output
6 DC OK* DC OK* +V
+V +V -V -V 2 L1
AC Input
DC DC
L1 L2 L3 DC DC 7 -V
OK OK +Is-Is 3 L2
LO ON
L 18
1 4
4 L3 8 -V
Voltage trim on underside
* Available on 24 V versions only
Notes
1. All dimensions in inches (mm). 5. DC OK Relay rated at 60 VDC at 300 mA.
2. Tolerance: 0.02 (0.5) maximum. 6. Allow 0.98 (25 mm) clearance all round to ensure adequate ventilation.
3. Weight - DNR120TS: 1.76 lb (800 g) approx. 7. Connection screw maximum torque: Input: 9 lbs-in (1.0 Nm),
DNR240TS: 2.43 lb (1100 g) approx. Output: 5.5 lbs-in (0.6 Nm).
DNR480TS: 4.23 lb (1720 g) approx. 8. Connecting +Ishare and -Ishare between two power supplies will force the units
DNR960TS: 7.05 lb (3200 g) approx. to current share.
4. Screw terminal: 10-24 AWG cable size.
Derating Curves
100
A
C B
75
A DNR120-240TS
65
B DNR960TS
C DNR480TS
0
-40 -30 60 70
Ambient Temp (C)
11-May-11
Load (%)