DC-HVDC Converter E Series 3 Watts Output Voltages from 100V to 12kV 2xxx 2ries Output Voltage Proportional to Input Low Turn-on Voltage 0.7VDC Input to Output Isolation Dual Output No Minimum Load 3 Year Warranty The E Series is a broad line of small, component level high voltage converters in a Dimensions: PCB mount package that provides up 3 Watts continuous output power for models E Series: up to 7kV (2 Watts for models >7kV). These HV converters feature low ripple and 2.50 x 1.5 x 0.85 (63.5 x 38.1 x 21.6mm) noise, and low EMI/RFI by utilizing a quasi-sinewave oscillator, excellent filtering techniques and a fully enclosed pot-core transformer. The output voltage is directly proportional to the input voltage and is linear from approximately 0.7 volts to Key Applications: maximum input. Mass Spectrometry Electrostatic Chucks The galvanically isolated output allows for user selectable output polarity. Dual output Electrophoresis models with a center-tap pin provide both positive and negative outputs from one Capacitor Charging module. Some models are provided with an external aluminum box for increased Particle Counter Ignition/Spark EMI/RFI shielding and rugged mounting. Proven design techniques, classic topology Sustaining Ion Pumps and custom encapsulation formula come together to provide engineers with a clean, reliable, low cost, and easy to integrate high voltage solution. Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 0.7 12, 15 VDC See Models and Ratings Table. Input Current, No Load 175 mA Input Current, Full Load 400 mA Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12,000 VDC See Models and Ratings Table Output Current 30 mA See Models and Ratings Table Output Voltage Tolerance +5, -5 % At Max Vout, Full Load Minimum Load No minimum load required Regulation Unregulated, Output is proportional to Input. See Application Notes. Ripple and Noise 0.05 1.5 % See Models and Ratings Table. Response Time 10 msec 0 to Max Vout, Full Load Notes 1. Maximum rated output current is available at maximum rated output voltage and 4. Proper thermal management techniques are required to maintain safe case derates linearly as input voltage is decreased. temperature at maximum power output. 2. Output voltage is load dependent. Under light or no-load conditions, reduce the 5. Ripple specification for center-tapped units applies to the voltage between the input voltage so maximum rated output voltage is not exceeded. positive and negative output terminals. 3. Specifications after 30 minute warm-up, full load, at 25C unless otherwise indicated. www.xppower.com 1DC-HVDC Converter E Series Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature (case) -10 +60 C Models E01 to E60 Operating Temperature (case) -10 +50 C Models E70 to E121 Storage Temperature -25 +90 C Humidity 95 %RH Non-condensing Cooling Natural Convection General Characteristic Minimum Typical Maximum Units Notes & Conditions Isolation: Input to Output 3,500 V < 3500 Bias for Models E01 to E60 Isolation: Input to Output 500 V < 500 Bias for Models E70 to E121 Switching Frequency 30 100 kHz Stable frequency over entire output voltage range. Construction Case material is Diallyl Phthalate (DAP). UL 94 V-0 rated solid vacuum encapsulation. Mean Time Between Failure 810 kHrs Bellcore TR 332 Block Diagram 1 3 (+) In (+) Output Rectifier & Oscillator Multiplier 5 Center tap (for Dual output option) 2 4 (-) In (-) Output Transformer External EMI/RFI Shield 4-40 solderable 3.40 grounding STUD 0.140 (3.56) (86.4) places thru 2 places 0.300 (7.62) 0.300 (7.62) 1.60 (40.6) 0.80 0.20 (20.3) (5.1) 3.000 (76.20) 2.60 (66.0) 0.31 (7.9) HIGH 0.90 VOLTAGE (22.9) 0.40 (10.2) An AB suffix is used to indicate an added external EMI/RFI Shield as shown above. These five-sided aluminum enclosures feature a durable, non-conductive black anodized finish. On models with outputs of 3kV or higher, special care must be taken to ensure adequate spacing and insulation between the metal can and the high voltage output. Single sided layout, encapsulation, or conformal coating may be required. Case grounding studs must be connected to ground. Case ground is not connected to (-) Input. www.xppower.com 2