AC-DC Power Supplies ECE60 Series 60 Watts Ultra Compact Size Single Outputs from 3.3 to 48 V Encapsulated PCB & Chassis Mount Versions <0.3 W No Load Input Power -40 to +70 C Operation Peak Load Capability 3 Year Warranty Dimensions: The ECE60 series of compact encapsulated AC-DC power modules are available in both PCB & ECE60: 3 chassis mount versions offering exceptional power density of >10W/in . Output voltages are 3.60 x 1.50 x 1.10 (91.4 x 38.1 x 28.0 mm) ECE60-S: available from 3.3 48 VDC and these green power modules offer high active mode efficiency 4.45 x 1.57 x 1.12 (113.0 x 40.0 x 28.5 mm) and low no load power consumption. They also provide a peak load capability up to 130% of nominal power for up to 30s and a wide operating temperature range from -40 to +70C. Models & Ratings Output Current (4) (2,3) Output Power Output Voltage Efficiency Model Number (1) Nominal Peak 33 W 3.3 V 10.00 A 13.00 A 79% ECE60US03 50 W 5.0 V 10.00 A 13.00 A 83% ECE60US05 60 W 9.0 V 6.67 A 8.67 A 87% ECE60US09 60 W 12.0 V 5.00 A 6.50 A 87% ECE60US12 60 W 15.0 V 4.00 A 5.20 A 88% ECE60US15 60 W 24.0 V 2.50 A 3.25 A 89% ECE60US24 60 W 36.0 V 1.67 A 2.17 A 88% ECE60US36 60 W 48.0 V 1.25 A 1.63 A 86% ECE60US48 Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal power. 2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE60US12-S. 3. A screw terminal version (-S) is available with DIN Clip attached. Add suffix D, e.g. ECE60US24-SD. DIN Rail mounting clip is available as a separate item, order code ECE60 DIN CLIP. 4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230 VAC input. Summary Characteristic Minimum Typical Maximum Units Notes & Conditions 85 264 VAC Input Range Derate load from 100% at 90 VAC to 90% at 85 VAC 120 370 VDC <0.3 W 12-36 V versions No Load Input Power <0.5 W 3.3-9 V & 48 V versions Efficiency 79 87 89 % See note 4 above Some specification parameters may not met below -25 C. Operating Temperature -40 +70 C Derate linearly from 100% load at +50 C to 50% load at 70 C. EMC EN55032 Level B Conducted & Radiated, EN61000-4, EN61000-3 Safety Approvals IEC / EN / UL 62368-1, CSA per cUL www.xppower.com 1AC-DC Power Supplies ECE60 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions 85 264 VAC Input Voltage - Operating Derate load from 100% at 90 VAC to 90% at 85 VAC 120 370 VDC Input Frequency 47 63 Hz Power Factor EN61000-3-2 class A compliant Input Current 0.6 A rms At 230 VAC 0.3 W 12-36 V versions No Load Input Power 0.5 W 3.3-9 V & 48 V versions Inrush Current 25/50 A 115/230 VAC cold start at 25 C Earth Leakage Current Class II construction no earth Input Protection Internal T2.5 A/250 VAC fuse Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 3.3 48 VDC See Models and Ratings table Initial Set Accuracy 1 % Minimum Load 0 A Start Up Delay 2 s Start Up Rise Time 30 ms Hold Up Time 16 ms At full load and 115 VAC Line Regulation 0.5 % 2 % ECE60US03/05-S Load Regulation 1 % All other models Recovery within 1% in less than 500 s Transient Response 4 % for a 25% load change 60 mV pk-pk 3.3-5 V versions, 20 MHz bandwidth 3.3-5 V -S versions, 20 MHz bandwidth, Ripple & Noise 75 mV pk-pk 0.1 F capacitor at output terminals 1 % pk-pk 20 MHz bandwidth all other models 195 216 % Vnom ECE60US03 models Overvoltage Protection 115 140 % Vnom All other models Overload Protection 110 180 % Short Circuit Protection Trip & restart (hiccup mode) Temperature Coefficient 0.05 %/C General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 79 87 89 % See Models & Ratings table Isolation 3000 VAC Input to Output 100 Switching Frequency kHz 3 Power Density 10.1 W/in Mean Time Between Failure >300 kHrs MIL-HDBK-217F, +25 C GB 0.42 (191) lb (g) ECE60 Weight 0.44 (200) ECE60-S Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Some specification parameters may not met below -25 C. Operating Temperature -40 +70 C Derate linearly from 100% load at +50 C to 50% load at 70 C. Storage Temperature -40 +85 C Cooling Convection-cooled Humidity 95 %RH Non-condensing Operating Altitude 3048 m Vibration 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins each cycle www.xppower.com 2