AC-DC Power Supplies XPPower ECP130 Series 130 Watts 100 W Convection/130 W Forced-cooled Ratings 2 by 3 Footprint Low 1.1 Profile High Efficiency, up to 95% Medical and ITE Approvals High Power Density Less than 0.5 W No Load Input Power 3 Year Warranty Dimensions: ECP130: 3.00 x 2.00 x 1.10 (76.2 x 50.8 x 28.0 mm) Models & Ratings Output Current Output Output (2) (3) Efficiency Model Number (1) Power Voltage Convection-cooled Forced-cooled 130 W 12.0 V 8.33 A 10.83 A 93% ECP130PS12 130 W 15.0 V 6.66 A 8.66 A 93% ECP130PS15 130 W 18.0 V 5.55 A 7.22 A 93% ECP130PS18 130 W 24.0 V 4.16 A 5.41 A 93% ECP130PS24 130 W 28.0 V 3.57 A 4.64 A 93% ECP130PS28 130 W 36.0 V 2.77 A 3.61 A 93% ECP130PS36 130 W 48.0 V 2.08 A 2.70 A 93% ECP130PS48 Notes 1. Requires 10 CFM. 2. Typical efficiency measured at full load and 230VAC input. 3. Add suffix -S for input and output screw terminals e.g. ECP130PS24-S Summary Characteristic Minimum Typical Maximum Units Notes & Conditions Input Range 85 115/230 264 VAC Derate load from 100% at 90 VAC to 85% at 85 VAC No Load Input Power 0.5 W Efficiency 95 % 230 VAC (see fig.1 & 2) Operating Temperature -30 +70 C See derating curve (fig.3) ITE IEC62368-1, UL62368-1, CSA 22.2 No.62368-1-11 Ed 2, EN62368-1, LVD Safety Approvals Medical IEC60601-1 Ed 3.1 Including Risk Management, ANSI/AAMI ES60601-1 & CSA C22.2 No.6061-1:08, EN60601-1 www.xppower.com 1 The ECP130 series is designed to minimize the no load power consumption and maximize efficiency to facilitate equipment design to meet the latest environmental legislation. Approved for medical and ITE applications, this range of single output AC-DC power supplies are packaged in a low profile 1.1 height with a foot print of just 2 by 3. The ECP130 provides up to 130 W force-cooled or 3 3 100 W convection-cooled leading to very high power densities of 19.7 W/in or 15.1 W/in respectively. The power supply contains two fuses and low leakage currents as required by medical applications and is safety approved to operate in a 70 C ambient. The low profile and safety approvals covering ITE and medical standards along with conducted emissions to EN55011/32 level B allow the versatile ECP130 series to be used in a vast range of applications.AC-DC Power Supplies XPPower ECP130 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 115/230 264 VAC Derate output from 100% at 90 VAC to 85% at 85 VAC Input Frequency 47 50/60 63 Hz Agency approval, 47-63 Hz Power Factor 0.8 230 VAC, 100% load EN61000-3-2 class A Input Current - Full Load 1.3/0.65 A 115/230 VAC Inrush Current 120 A 230 VAC cold start, 25 C Earth Leakage Current 20/40 50 A 115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max) No load Input Power 0.5 W Input Protection F3.15 A/250 V Internal fuse fitted in line and neutral. Output - Main Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 VDC See Models and Ratings table Initial Set Accuracy 1 % 50% load, 115/230 VAC Output Voltage Adjustment % None Minimum Load 0 A No minimum load required Start Up Delay 2 s 115/230 VAC full load. Hold Up Time 10 15/11 ms Min at full load, 115 VAC. Typical at 100W/ 130W Drift 0.02 % After 20 min warm up Line Regulation 0.5 % 90-264 VAC Load Regulation 0.5 % 0-100% load. Recovery within 1% in less than 500 s Transient Response 4 % for a 50-75% and 75-50% load step Over/Undershoot 7 % Full load <2% from no load to 10% load, <1% above 10% load. Ripple & Noise 1 % pk-pk 20 MHz bandwidth and 10 F electrolytic capacitator in parallel with 0.1 F ceramic capacitator. Overvoltage Protection 110 140 % Vnom, recycle input to reset Overload Protection 110 170 % I nom Short Circuit Protection Trip & Restart Temperature Coefficient 0.02 %/C General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 95 % 230 VAC (see fig. 1 & 2) 4000 VAC 2 MOPP Isolation: Input to Output Input to Ground 1500 VAC 1 MOPP Output to Ground 1500 VAC 1 MOPP 40 130 kHz PFC Switching Frequency 50 135 kHz Main converter 3 Power Density 19.7/15.1 W/in Forced/convection-cooled Mean Time Between Failure 680 kHrs MIL-HDBK-217F, Notice 2 +25 C GB Weight 0.25(115) lb(g) www.xppower.com 2