225 Watts xppower.com ECP Series Low 1Profile with 2.5x 5 Footprint 150/225 W Convection/ Forced-cooled High Efficiency - up to 95% Medical & ITE Approvals Built-in Fan Supply <0.5 W No Load Input Power 3 Year Warranty Specification Input General Input Voltage 85-264 VAC, Derate from 100% at 90 VAC Efficiency See table to 90% at 85 VAC Isolation 4000 VAC Input to Output Input Frequency 47-63 Hz 1500 VAC Input to Ground 1500 VAC Output to Ground Input Current 2.2 A typical at 115 VAC, 1.1 A typical at 230 VAC Protection Level Primary to Secondary: 2 MOPP Primary to Earth: 1 MOPP Inrush Current 120 A max at 230 VAC, cold start at 25 C Secondary to Earth: 1 MOPP Power Factor >0.95 at full load 3 Power Density 12/18 W/in convection/forced-cooled, Earth Leakage Current <230 A at 264 VAC, 60 Hz Switching Frequency PFC: 70-130 KHz, PWM: 50-80 KHz No Load Input Power <0.5 W MTBF >300 kHrs to MIL-HDBK-217F at 25 C, GB Input Protection Internal T3.15A/250VAC fitted in line and neutral Environmental Operating Temperature -20 C to +70 C derate from 100% load Output at 50 C to 50% load at 70 C Output Voltage See tables Cooling Convection cooled: 150 W Output Voltage Trim 5% Forced cooled: 225 W with 10 CFM Initial Set Accuracy 1% at 50 % load Operating Humidity 5% to 90% RH, non condensing Minimum Load No minimum load requirement Operating Altitude 5000 m Start Up Delay 2 s max Storage Temperature -40 C to +85 C Start Up Rise Time 55 ms typical Shock IEC68-2-27, 30 g, 11 ms half sine, 3 times Hold Up Time 10 ms minimum at full load and 115 VAC in each of 6 axes 20 ms typical at 150 W, 13 ms typical at Vibration IEC68-2-6, 10-500 Hz, 2 g 10 mins / 225 W sweep. 60 mins for each of 3 axes Line Regulation 0.5% max Load Regulation 0.5% max EMC & Safety Transient Response 4% maximum deviation, recovering to less Emissions EN55032/11, Level B conducted & Level than 1% within 500 s for 25% step load A radiated, Level B radiated with external core, see note 5. Ripple & Noise 1% max pk-pk, 20 MHz bandwidth, (see note 2) Harmonic Currents EN61000-3-2 Class A Overvoltage Protection 110% - 140% of nominal voltage on main EN61000-3-2 Class C for load >145 W output. Recycle mains to reset. Voltage Flicker EN61000-3-3 Overload Protection 110-170% ESD Immunity EN61000-4-2, 8 kV air, 4 kV contact, Perf Criteria A Short Circuit Protection Trip and restart (hiccup) Thermal Protection Measured internally. Auto resetting. Radiated Immunity EN61000-4-3, 3 V/m, Perf Criteria A Temperature 0.02%/C EFT/Burst EN61000-4-4, level 3, Perf Criteria A Coefficient Surge EN61000-4-5, installation class 3, Fan Supply 12 V at 500 mA Perf Criteria A Conducted Immunity EN61000-4-6, 3 V, Perf Criteria A Dips & Interruptions EN55024, 100% 10 ms, 30%, 500 ms, 100%, 5000 ms Perf Criteria A, A, B for high line, A, B, B for low line at full load, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B for high line, A, B, A, B for low line at full load Safety Approvals UL62368-1, IEC62368-1, EN62368-1, ANSI/AAMI ES 60601-1, IEC60601-1, EN60601-1 AC-DCAC-DC ECP225 Models and Ratings Output Current Ripple and Noise (3) (4) Output Voltage Fan Output Efficiency Model Number (2) (1) pk-pk Convection-cooled Forced-cooled 12.0 V 12.50 A 18.75 A 120 mV 12 V/0.5 A 93% ECP225PS12 15.0 V 10.00 A 15.00 A 150 mV 12 V/0.5 A 93% ECP225PS15 24.0 V 6.25 A 9.38 A 240 mV 12 V/0.5 A 94% ECP225PS24 28.0 V 5.36 A 8.04 A 280 mV 12 V/0.5 A 94% ECP225PS28 48.0 V 3.10 A 4.69 A 480 mV 12 V/0.5 A 94% ECP225PS48 Notes 1. Requires 10 CFM. 4. 3 x 5 Footprint available for OEM quantities, add suffix -3X5to part eg. 2. Measured with 20 MHz bandwidth and 10 F electrolytic capacitor in parallel ECP225PS24-3X5. with 0.1 F ceramic capacitor 5. To meet Level B radiated, a torroid is required on output load leads. Use King 3. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of Core type K5B RC 25*12*15 for all models except 28V which requires type 225 W load and 230 VAC input. K5B T 16.5*13*8.2. Mechanical Details CN1 - Input Connector Pin 1 Neutral 5.00 (127.0) Pin 2 Not Fitted Pin 3 Line 4.75 (120.6) Mates with JST housing 0.25 (6.35) Faston ground tab VR VHR-3N and JST Series SVH-21T-P1.1 crimp terminals 8 Mounting holes marked with must be connected to safety earth 2.25 (57.1) CN2 - Output Connector CN2 Pin 1 -Vout 2.50 (63.5) Pin 2 -Vout 3 1 Pin 3 -Vout CN1 Pin 4 -Vout 1 Pin 5 +Vout 2 CN3 1 Pin 6 +Vout Mounting Screw Pin 7 +Vout Holes 4 Places Pin 8 +Vout 0.134 (3.4 0.3) Mates with JST housing VHR-8N and JST Series 0.06 SVH-21T-P1.1 crimp terminals 0.83 1.00 (1.60) (21.0) (25.4) CN3 - Fan Connector Pin 1 Fan - Pin 2 Fan + Mates with Molex housing 0.11 22-01-1022 and 2759 crimp terminals (2.80) Notes 1. All dimensions shown in inches (mm). 3. Non earthed mounting hole on secondary side requires insulated mounting to Tolerance: 0.02 (0.5) maintain 1 MOPP secondary to ground. 2. Weight: 0.51 lbs (230 g) approx. Derating Curve 100 80 60 40 20 0 -20 -10 0 40 50 60 70 80 10 20 30 Ambient Temperature (C) 12 Nov 2020 Output Power (%)