ECS65 Series IT & Medical Safety Approvals <0.5 W Standby Power 65 W Convection Cooled Rating Industry Standard 2.0 x 4.0 x 1.05 Format Low Earth Leakage Current Class B Radiated Emissions (-B models) Low Temperature Operation 3 Year Warranty The ECS65 Series has been designed to minimise the no load power consumption (<0.5 W) and maximise efficiency in order to facilitate equipment design to the latest environmental legislation. Approved for Class I applications, the ECS65 range of single output AC-DC, 65 W power supplies feature high power density in an industry standard 2 x 4 (51.0 mm x 102.0 mm) footprint. The 1.05 (27.0 mm) high, 1U compatible high-density power supplies meet EN55032 Level B emissions with low earth leakage currents of 110 A at 115 VAC or 210 A at 230 VAC. Making these switchers ideal for industrial, IT and medical applications. The ECS65 series has single output versions from 12 V to 48 VDC which are adjustable by 10%. They are dual-fused for compliance with IEC60601-1 and with typical efficiencies at 88%, minimal waste heat is generated. The ECS65 delivers a full 65 W of power up to +50 C and operates at up to +70 C with derating.xppower.com Models and Ratings (1) Output Power - Convection Cooled Output Voltage V1 Max Output Current Model Number 65 W 12.0 VDC 5.4 A ECS65US12 65 W 15.0 VDC 4.3 A ECS65US15 65 W 18.5 VDC 3.4 A ECS65US18 65 W 24.0 VDC 2.7 A ECS65US24 65 W 28.0 VDC 2.3 A ECS65US28 65 W 48.0 VDC 1.4 A ECS65US48 Notes: 1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix -C to model number or order part no. ECM40/60 COVER for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations. Input Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 80 115/230 264 VAC Derate output power < 90 VAC. See fig. 1 Input Frequency 47 50/60 400 Hz 400Hz for ECS65 only 230 VAC, 100% load > Power Factor 0.5 EN61000-3-2 class A compliant Input Current - No Load 0.02/0.03 A 115/230 VAC Input Current - Full Load 1.0/0.6 A 115/230 VAC Inrush Current 40 A 230 VAC cold start, 25 C No Load Input Power 0.4 0.5 W 110/210 260 A 115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.) Earth Leakage Current 0.7/1.5 mA 115/230 VAC/400 Hz Input Protection T3.15A/250 V internal fuse in both line and neutral Output Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 48 VDC See Models and Ratings table Initial Set Accuracy 1 % 50% load, 115/230 VAC Output Voltage Adjustment 10 % Via potentiometer. See mech. details (page 9) Minimum Load0A Start Up Delay 1s 230 VAC full load (see fig.2) Hold Up Time 16 ms 115 VAC full load (see fig.3) Drift 0.2 % After 20 min warm up Line Regulation 0.5 % 90-264 VAC Load Regulation 1 % 0-100% load. Recovery within 1% in less than 500 s Transient Response - V1 4% for a 50-75% and 75-50% load step Over/Undershoot - V1 5% See fig.4 Ripple & Noise 1 % pk-pk 20 MHz bandwidth (see fig.5 & 6) Overvoltage Protection 115 140 % Vnom DC. Overload Protection 110 160 % I nom Auto reset (see fig.7) Short Circuit Protection Continuous, trip & restart (hiccup mode) Temperature Coefficient 0.05 %/C Overtemperature Protection C Not fitted 2