AC-DC Power Supplies XPPower EME05 Series 5 Watts Compact Size Medical Approvals (2 x MOPP) Single Outputs from 3.3 to 48VDC Open Frame & Encapsulated PCB Mount Class II Peak Load Capability No External Components Required GREEN POWER 3 Year Warranty Dimensions: EME05: The EME05 is a series of open frame and encapsulated AC-DC single output power supplies 1.50 x 1.00 x 0.60 (36.1 x 25.4 x 15.2 mm) EME05-P: designed for medical applications. The series provides two mechanical options including open 1.40 x 0.94 x 0.69 (35.6 x 23.7 x 17.6 mm) frame and encapsulated PCB mount. With approvals to world-wide medical safety standards, compliance with class B for both conducted and radiated emissions and a 130%, 30s peak load capability, these class II isolation parts benefit system designers with easy integration into the latest healthcare products and applications. Models & Ratings Output Current (2) Output Power Output Voltage Model Number (1) Nominal Peak 5 W 3.3 VDC 1510 mA 1960 mA EME05US03 5 W 5.0 VDC 1000 mA 1300 mA EME05US05 5 W 9.0 VDC 555 mA 722 mA EME05US09 5 W 12.0 VDC 416 mA 541 mA EME05US12 5 W 15.0 VDC 333 mA 433 mA EME05US15 5 W 24.0 VDC 208 mA 270 mA EME05US24 5 W 36.0 VDC 138 mA 180 mA EME05US36 5 W 48.0 VDC 104 mA 135 mA EME05US48 Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. 2. For Open Frame version add suffix -P to model number, e.g. EME05US12-P. Summary Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage Range 85 264 VAC Derate from 100% at 90 VAC to 90% at 85 VAC No Load Input Power 0.3 W Efficiency 72 86 % Operating Temperature -25 +70 C Derate linearly from 100% at +50 C to 50% at +70 C EMC EN55011 Level B Conducted & Radiated, EN601000-3-2, EN61000-3-3, EN60601-1-2 Safety Approvals EN60601-1, ANSI/AAMI ES60601-1. IEC60601-1 www.xppower.com 1AC-DC Power Supplies XPPower EME05 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage Range 85 264 VAC Input Frequency 47 63 Hz Input Current - Full Load 0.10/0.06 A rms At 115/230 VAC No Load Input Power 0.3 W Inrush Current 40 A At 230 VAC Earth Leakage Current Class II construction no earth Input Protection Internal T1.0 A/250 VAC fuse fitted in line and neutral Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 3.3 48 VDC Initial Set Accuracy 1 % Minimum Load 0 A No minimum load required Start Up Delay 2 s Start Up Rise Time 14 ms Hold Up Time 12 ms at full load and 115 VAC Line Regulation 0.5 % Load Regulation 1 % Deviation, recovery within 1% in less than 500 s Transient Response 4 % for a 25% load change 50 mV pk-pk 3.3-5 V versions, 20 MHz bandwidth 90 mV pk-pk 9 V versions, 20 MHz bandwidth Ripple & Noise 120 mV pk-pk 12-15 V versions, 20 MHz bandwidth 200 mV pk-pk 24-48 V versions, 20 MHz bandwidth Overvoltage Protection 115 140 % Vnom Recycle input to reset Overload Protection 130 200 % Short Circuit Protection Trip & Restart (hiccup mode) Temperature Coefficient 0.05 %/C General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 80 % Isolation: Input to Output 4000 VAC 2 x MOPP Switching Frequency kHz 130 3 Power Density 5.5 W/in Mean Time Between Failure >400 kHrs MIL-HDBK-217F, +25 C GB 0.03 (14) lb (g) Open frame versions (-P) Weight 0.053 (24) lb (g Encapsulated version Efficiency Graphs EME05US12 EME05US24 100% 100% 90% 90% 80% 80% 70% 70% 115Vac input 230Vac input 60% 60% 50% 50% 40% 40% 10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 Load (%) Load (%) www.xppower.com 2 Efficiency y