AC-DC Power Supplies FCS60 Series 60 Watts 60 W Convection Rating 2 by 4 Footprint Low 1.04 Profile High Efficiency Medical, ITE and Household Appliance Approvals Class I & Class II Installations High Power Density Less than 0.3 W No Load Input Power 3 Year Warranty Dimensions: The FCS60 series is designed to minimize the no load power consumption and maximize efficiency to facilitate equipment design to meet the latest environmental legislation. Approved for medical and FCS60: ITE applications in either Class I or Class II installations, this range of single output AC-DC power supplies 2.00 x 4.00 x 1.04 (50.8 x 101.6 x 26.4 mm) are packaged in a low profile 1.04 height with a foot print of just 2 by 4. The FCS60 provides up to 60W convection-cooled and operates down to 80 VAC. The power supply features two AC line fuses and low leakage currents required by medical applications. The low profile, low noise and safety approvals covering ITE and medical standards allows the versatile FCS60 series to be used in a wide range of applications. Models & Ratings (1) Output Power Output Voltage Output Current Efficiency Model Number 60 W 12.0 V 5.00 A 85% FCS60US12 60 W 15.0 V 4.00 A 85% FCS60US15 60 W 18.0 V 3.33 A 85% FCS60US18 60 W 24.0 V 2.50 A 85% FCS60US24 60 W 36.0 V 1.67 A 86% FCS60US36 60 W 48.0 V 1.25 A 86% FCS60US48 Notes 1. Typical efficiency measured at full load and 230 VAC input. Mechanical Details 4.0 (101.60) 3.75 (95.24) CN1 - Input Connector 0.134 (3.4) Pin 1 Line thru in 4 positions Pin 2 Not Fitted COCONN 11 22 Neutral Pin 3 Neutral COCONN 22 Line 11 1 +VE 2.0 Mates with JST housing VHR-3N and JST 2 -VE (50.8) Series SVH-21T-P1.1 crimp terminals 1.75 Output Voltage (44.4) Adjustment Mounting hole marked with must be connected to safety earth for class I applications 0.125 (3.17) 0.125 (3.17) CN2 - Output Connector Pin 1 +Vout 0.92 (23.4) 1.04 Pin 2 -Vout (26.4) Mates with JST housing VHR-2N and JST Series SVH-21T-P1.1 crimp terminals 0.12 (3.0) Notes 1. All dimensions shown in inches (mm). 2. Weight: 0.25 lbs (112 g) approx. Tolerance: 0.02 (0.5) www.xppower.com 1AC-DC Power Supplies FCS60 Series Summary Characteristic Minimum Typical Maximum Units Notes & Conditions Derate output from 100% at 90 VAC to 90% at 85 VAC and Input Range 80 115/230 264 VAC 80% at 80 VAC No Load Input Power 0.3 W Efficiency 85 % 230 VAC (see models and ratings table) Operating Temperature -25 +70 C See derating curve (fig.1) ITE IEC60950-1, IEC62368-1, EN62368-1, cUL62368-1 Safety Approvals Medical IEC60601-1 Ed 3.1 Including Risk Management, ANSI/AAMI ES60601-1 & CSA C22.2 No.6061-1:08, EN60601-1 Household IEC60335-1 Input Characteristic Minimum Typical Maximum Units Notes & Conditions Derate output from 100% at 90 VAC to 90% at 85 VAC and Input Voltage - Operating 80 115/230 264 VAC 80% at 80 VAC Input Frequency 47 50/60 63 Hz Agency approval, 47-63 Hz Power Factor EN61000-3-2 class A Input Current - Full Load 0.9/0.5 A 115/230 VAC Inrush Current 60 A 264 VAC cold start, 25 C Earth Leakage Current 270 A 264 VAC/60 Hz No load Input Power 0.3 W Input Protection T3.15 A/250 A, 250 V Internal fuse fitted in line and neutral. Output - Main Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 VDC See Models and Ratings table Initial Set Accuracy 1 % 50% load, 115/230 VAC Output Voltage Adjustment 10 % Minimum Load 0A No minimum load required Start Up Delay 12 s Output Rise Time 50 ms Hold Up Time 8.3/20 ms Min at full load 115/230 VAC Line Regulation 0.5 % 90-264 VAC Load Regulation 1% 0-100% load. Recovery within 1% in less than 500 s Transient Response 4% for a 50-75% and 75-50% load step Over/Undershoot 5% Full load Ripple & Noise 1.0 % pk-pk 20 MHz bandwidth Overvoltage Protection 115 140 %Vnom Continuous trip and restart (hiccup) Overload Protection 110 160 % I nom Short Circuit Protection Continuous trip and restart (hiccup) Temperature Coefficient 0.05 %/C General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 85 % 115/230 VAC 100% load 4000 VAC 2 MOPP Isolation: Input to Output Input to Ground 1500 VAC 1 MOPP Output to Ground 500 VAC 1 MOPP at output voltage 3 Power Density 7.2 W/in Mean Time Between Failure 500 kHrs MIL-HDBK-217F, Notice 2 +25 C GB Weight 0.25 (112) lb(g) www.xppower.com 2