130 Watts xppower.com JPS Series High Efficiency - up to 90% Medical Approval (JPS130-M Versions) 3x 5Footprint 100 W Convection-cooled 130 W Forced-cooled Single & Multi Outputs 3 Year Warranty Specification Input General Input Voltage 90-264 VAC (130-370 VDC) Efficiency Up to 90% nominal line, full load Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output (JPS130), 4000 VAC Input to Output (JPS130-M Input Current 2.0/1.0 A max at 115/230 VAC (JPS130) 2.6/1.3 A max at 115/230 VAC (JPS130-M) 2 x MOPP), 1500 VAC Input to Ground (JPS130-M 1 x MOPP), Inrush Current 30 A at 115 VAC, 60 A at 230 VAC, 500 VAC Output to Ground cold start at 25 C Switching Frequency 120 kHz, 10% for both active PFC & PWM Power Factor 0.9 typical 3 Power Density 6.7 W/In Earth Leakage Current 1.5 mA max at 264 VAC/60 Hz (JPS130) 260 A max at 275 VAC/63 Hz (JPS130-M) MTBF 200 kHrs to MIL-HDBK-217F at 50 C, GB Input Protection JPS130 internal T3.15 A/250 VAC fused line, Environmental JPS130-M fused line & neutral Operating Temperature 0 C to +70 C, (see derating curves) Cooling JPS130PS03 83 W convection-cooling, Output 100 W, with 18 CFM airflow. Output Voltage See table All others, 100 W with convection Output Voltage Trim 10% on single output models, cooling,130 W with 18 CFM airflow 5% on multi output models, Operating Humidity 5-95% RH, non-condensing auxiliary outputs will track by the same Storage Temperature -40 C to +85 C (JPS130) percentage -20 C to +85 C (JPS130-M) Initial Set Accuracy At 60% rated load 1% single outputs, Operating Altitude 3000 m 3% on V1 for multi outputs Minimum Load Single output: no minimum load required EMC & Safety Multi-outputs: (see note 1) Emissions EN55022, Class B conducted Start Up Rise Time <20 ms FCC 20780, level B conducted Hold Up Time 16 ms typical at 115 VAC & rated load (JPS130) EN60601-1-2, (JPS130-M) 20 ms typical at 115 VAC & rated load (JPS130-M) Harmonic Currents EN61000-3-2 Class A Drift <0.2% after 20 mins warm up Voltage Flicker EN61000-3-3 Line Regulation 0.5% Vmin to Vmax ESD Immunity EN61000-4-2, level 3 contact, level 3 air, Perf Load Regulation 1%, 5% for auxiliary outputs, Criteria A 20%-100% of rated load Radiated Immunity EN61000-4-3, 10 V/m Perf Criteria A Transient Response 4% max deviation, recovery to within 1% in 500 s for a 25% load change EFT/Burst EN61000-4-4, level 3 Perf Criteria A Ripple & Noise 1% max pk-pk (see note 4) Surge EN61000-4-5, Installation Class 3 Perf Criteria A Overvoltage Protection 110-140% Vnom on V1 only, recycle input to reset Conducted Immunity EN61000-4-6, level 2, Perf Criteria A Overload Protection 110-150%, auto recovery Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, Short Circuit Protection Trip & restart (hiccup mode), auto recovery 95% 5000 ms Perf Criteria A, B, B Temperature 0.05%/C Safety Approvals JPS130: EN60950-1, UL60950-1, Coefficient CSA C22.2 No. 60950-1, CE Mark LVD, EN62368-1 Remote Sense Single output models only, compensates for JPS130-M: UL60601-1, EN60601-1, up to 0.5 V drop CSA C22.2 No. 601.1 Fan Output 12 V, 450 mA multi-output models only CE Mark LVD. AC-DCAC-DC JPS130 Models and Ratings Output Current Output Output Ripple & Noise Standard Model Medical Model (3) (4) Power Voltage Pk-Pk Number Number Convection-cooled 18 CFM 100 W 3.3 V 25.0 A 30.0 A 50 mV JPS130PS03 5.0 V 20.0 A 26.0 A 50 mV JPS130PS05 JPS130PS05-M 12.0 V 9.0 A 10.8 A 120 mV JPS130PS12 JPS130PS12-M 15.0 V 7.0 A 8.7 A 120 mV JPS130PS15 JPS130PS15-M 130 W 24.0 V 4.5 A 5.4 A 200 mV JPS130PS24 JPS130PS24-M 28.0 V 3.8 A 4.6 A 200 mV JPS130PS28-M 48.0 V 2.1 A 2.7 A 200 mV JPS130PS48 JPS130PS48-M (1) + 5.0 V 11.5 A 15.0 A 50 mV (2) 130 W +12.0 V 3.0 A 5.0 A 100 mV JPS130PT31 (2) -12.0 V 0.5 A 0.5 A 100 mV (1) + 3.3 V 10.0 A 15.0 A 50 mV (2) 130 W +5.0 V 8.0 A 15.0 A 50 mV JPS130PT30 (2) +12.0 V 0.5 A 0.5 A 100 mV (1) + 5.0 V 10.0 A 15.0 A 50 mV (2) 130 W +12.0 V 3.0 A 4.1 A 120 mV JPS130PT31-M (2) -12.0 V 0.8 A 1.1 A 120 mV (1) +5.0 V 10.0 A 15.0 A 50 mV (2) 130 W +15.0 V 2.5 A 4.1 A 150 mV JPS130PT32-M (2) -15.0 V 0.8 A 1.1 A 150 mV (1) +5.0 V 2.5 A 4.0 A 50 mV (2) 130 W +24.0 V 2.8 A 4.0 A 240 mV JPS130PT34-M (2) +12.0 V 0.7 A 1.0 A 120 mV Notes 1. 20% minimum load required on V1 to maintain stated regulation for 5. Covers available, order part number JPS130-M COVER or add suffix -C auxiliary rails. to receive the unit with cover fitted. Overall dimensions 89.5 x 143.0 x 2. Load regulation of auxiliary rails is defined over the range of 20%-100% 40.0 mm. For industrial units order part number JPS130 COVER or add of rated load. suffix -C to receive the unit with cover fitted. Overall dimensions 90.6 x 3. Maximum power with 18 CFM of forced air. 142.9 x 39.8 mm. Fixing screws M3, maximum penetration depth 3mm 4. Ripple and noise measured over 15 MHz bandwidth with a 47 F from cover outer surface. electrolytic capacitor and 0.47 F ceramic capacitor. 6. Connector kits and cable harnesses available. Consult sales for options. Mechanical Details JPS130-M PIN CONNECTIONS 0.16 (4.0) Dia Mounting Hole (4 Places) 0.22 (5.7) 0.2 (5.0) -M TB2 PS05 PS 12 - 48 PT31 PT32 PT34 1 Return Return -12 V -15 V +12 V 2 Return Return +12 V +15 V +24 V 3 Return Return Return Return Return TB2 TB2 L 1 4 Return +V Return Return Return 5 +V +V Return Return Return N TB1 6 +V +V Return Return Return 7 +V +5 V +5 V +5 V 1 8 +V +5 V +5 V +5 V -M version Voltage Trim 9 +5 V +5 V +5 V Type *5273-08A *5273-06A *5273-09A 1 TB3 4.55 (115.6) 4.60 (117.0) -M JPS130 PIN CONNECTIONS 5.00 (127.0) TB2 PS05 PS03, 12 - 48 PT31 PT30 To Chassis Grounding x 2 1 +V +V +5 V +3.3 V 2 +V +V +5 V +3.3 V 3 +V +V +5 V Return 0.10 4 +V Return Return Return (2.5)max 5 Return Return Return Return 6 Return Return Return Return 7 Return Return Return TB3 PIN CONNECTIONS 8 Return +12 V +5 V All dimensions are in inches (mm). Pin Single Multi Tolerance: 0.02 (0.4) max. 9 -12 V +5 V 1 - Sense 0 V Weight: 0.5 lbs (240 g) approx. 10 +12 V 2 + Sense +12 V Fan Type *5273-08A *5273-06A *5273-09A *5273-10A Notes * Note: MOLEX connector type 1. Single output industrial model shown, add extra 0.08 (2.0 mm) to overall height for multi-output models. Dimensions followed by -M apply for Derating Curves medical units (note output connector orientation). 2. AC input connector (TB1): Molex 5277-02A or equivalent. Mates with 130 A JPS130 and -M with 18 CFM fan 5196-N housings/5194/5225 crimps. A (except JPS130PS03). 3. DC output connector (TB2): Molex 5273 or equivalent, mates with 5195-N 100 housing/5194/5225 crimps and 5239-N housing/5167/5168/2478/2578 C B B JPS130PS12, PS15, PS24 and PS48 80 D and -M with convection cooling. crimps. Except JPS130PS03 which has a 6-position terminal screw JPS130PS03 with 18 CFM fan. 60 block: Dinkle part number EHK508V Series accepts 24-12 AWG wire. Terminal screw tightening torque 4 lbs-in (0.45 Nm) maximum. C JPS130PS05, PT30, PT31, PT32 and 40 PT34 and -M with convection cooling. 4. TB3: Molex 5045-02A or equivalent. Mates with KK 51191 20 housings/50802 crimps and KK 5051 housings/2759/5159 crimps. Single D JPS130PS03 with convection cooling. 0 output units - TB3 is remote sense. Multi-output units - TB3 is 12 V, 20 30 40 -10 0 10 50 60 70 450 mA fan output. Ambient Temp (C) 16 Dec 2020 (1) 1.18 (30.0) max 3.00 (76.2) 2.55 (64.8) 2.60 (66.2) -M Load (W)