xppower.com 500-600 Watts SMC/SMD Series High Peak Load Rating Single Outputs from 3.3 V to 54 V Active PFC Remote On/Off Optional Current Share SEMI F47 Compliant 3 Year Warranty Specification Input General Efficiency 80% min at 230 VAC, 70% min for Vo 5V Input Voltage 90-264 VAC (120-370 VDC) Isolation 3000 VAC Input to Output, Input Frequency 47-63 Hz 1500 VAC Input to Ground, Input Current 9 A at 90 VAC, 3.5 A at 230 VAC 250 VDC Output to Ground Inrush Current 40 A at 230 VAC Switching Frequency 100 kHz PFC, 25 kHz PWM typical Power Factor EN61000-3-2 class A 3 Power Density 6.93 W/In EN61000-3-2 class C for load 40% Signals Green LED for Power On, Power Good Earth Leakage Current <2.4 mA max at 264 VAC TTL HIGH within 100-500 ms and LOW 1 ms before loss of regulation Input Protection Fitted with a T10 A/250 V fuse Current Monitor 0.5 V to 3 V output voltage denoting 0-100% output current Output MTBF 100 kHrs min to MIL-HDBK-217F Output Voltage See tables at 25 C, GB Output Voltage Trim 5% minimum Environmental Initial Set Accuracy 1% Operating Temperature 0 C to +70 C, derate from 100% load at Minimum Load 1% load required to meet specified +50 C to 50% load at +70 C ripple & noise and regulation Cooling 30 CFM for SMD U-channel versions Start Up Delay 1.5 s at 230 VAC, 2.5 s at 110 VAC (SMC Versions have integral fan) Start Up Rise Time 40 ms typical Operating Humidity 5-90%, non-condensing Hold Up Time 18 ms min at 120 VAC Storage Temperature -20 C to +85 C Line Regulation 0.5%, low line to high line Operating Altitude 3000 m Load Regulation 1%, 1-100% of load, see note 4 Shock 15 g (non-operation), 11 ms (half sine Over/Undershoot 5% max wave), 3 times for each axis Transient Response 5% max deviation, 500 s recovery to Vibration 10-55 Hz (non-operation) 2 g, sweep time within 1% for a 50% load change 3 mins, 60 mins/axis Ripple & Noise See table EMC & Safety Overvoltage Protection 110-130% recycle input to reset Emissions EN55032 Class B conducted Overtemperature >85 C ambient with auto recovery Harmonic Currents EN61000-3-2 class A Protection (measured internally) EN61000-3-2 class C for load 40% Overload Protection 110% to 135% with auto recovery Voltage Flicker EN61000-3-3 Short Circuit Protection Trip and restart (Hiccup mode) ESD Immunity EN61000-4-2, level 3 Perf Criteria A Remote Sense Compensates for up to 0.5 V line drop Radiated Immunity EN61000-4-3, 3 V/m Perf Criteria A (not available with current share) EFT/Burst EN61000-4-4, level 2 Perf Criteria A Remote On/Off On = TTL Logic HIGH, or open circuit Surge EN61000-4-5, installation class 3 Off = TTL Logic LOW or short circuit Perf Criteria A Current Share Optional single wire current share, will Conducted Immunity EN61000-4-6, 3V Perf Criteria A allow up to 4 units share within 10%, Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, includes ORing diode 100% 5000 ms Perf Criteria A, B, B Safety Approvals EN62368-1, UL62368-1, CSA62368-1 via cUL, CE Mark LVD, SEMI F47 Compliant (high line only) at 100% rated power output AC-DCAC-DC SMC/SMD Series Models and Ratings (3) Output Voltage Output Current Output Ripple Model (2) (1) Power Preset Maximum Peak & Noise Number (6) 264 W 3.3 V 80.00 A 120.00 A 75 mV SMC500PS03-C (6) 400 W 5.0 V 80.00 A 120.00 A 75 mV SMC500PS05-C 12.0 V 41.67 A 75.00 A 120 mV SMC500PS12-C (6) 15.0 V 31.00 A 56.00 A 150 mV SMC500PS15-C (6) 18.0 V 27.78 A 50.00 A 180 mV SMC500PS18-C 24.0 V 20.83 A 37.50 A 240 mV SMC500PS24-C 500 W (6) 27.0 V 18.50 A 33.33 A 270 mV SMC500PS27-C (6) 36.0 V 13.89 A 25.00 A 360 mV SMC500PS36-C 48.0 V 10.42 A 18.75 A 480 mV SMC500PS48-C (6) 54.0 V 9.25 A 16.67 A 540 mV SMC500PS54-C (6) 297 W 3.3 V 90.00 A 135.00 A 100 mV SMC600PS03-C (6) 450 W 5.0 V 90.00 A 135.00 A 100 mV SMC600PS05-C 12.0 V 50.00 A 75.00 A 120 mV SMC600PS12-C (6) 15.0 V 40.00 A 56.00 A 150 mV SMC600PS15-C (6) 18.0 V 33.00 A 50.00 A 180 mV SMC600PS18-C 24.0 V 25.00 A 37.50 A 240 mV SMC600PS24-C 600 W (6) 27.0 V 22.22 A 33.33 A 270 mV SMC600PS27-C (6) 36.0 V 16.67 A 25.00 A 360 mV SMC600PS36-C 48.0 V 12.50 A 18.75 A 480 mV SMC600PS48-C (6) 54.0 V 11.10 A 16.67 A 540 mV SMC600PS54-C Notes 1. This peak can be taken for 500 s only, average power should not exceed the maximum power. 2. Ripple & Noise is measured using 0.1 F ceramic and 22 F electrolytic capacitor, 20 MHz bandwidth. 3. Alternative output voltages available, consult sales. 4. Load regulation increases to 2% for 0-100% load change. 5. For output currents >50 A, please utilise r emote sense to meet regulation ratings. 6. Available for OEM quantities, contact Sales. Options For U-channel version replace SMC in the part number with SMD and remove -C e.g. SMD600PS12 (See Derating Curve Note 1.) Constant current limit (95-100%) add suffix -B (not available on 3.3 V or 5.0 V models), OEM quantities contact Sales. Current share and internal ORing diode add suffix -I to model number, remote sense not available on -I models, OEM quantities contact Sales. Optional IEC320 inlet replace suffix -C with -D. Not available for SMD models. Derating Curve 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) Notes 1. SMD units require 30 CFM forced air cooling. Load (%)