xppower.com 5 Watts VCP Series Low Cost Universal AC Input Output Voltage from 5 to 15 V PCB Mount Class II Construction EN55022 Class B Emissions No Load Input Power <0.3 W BRAND Specification Input General Input Voltage 90-264 VAC Efficiency See table Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output Input Current 0.2 A max at 90 VAC Switching Frequency 60 kHz typical Inrush Current 40 A max at 240 VAC, cold start at 25 C MTBF 250 kHrs to MIL-HDBK-217F at 25 C, GB Power Factor EN61000-3-2, class A Environmental No Load Input Power <0.3 W Operating Temperature 0 C to +70 C, derate from 100% load at 50 C to 50% load at 70 C Output Cooling Natural convection Output Voltage See table Operating Humidity 10-90% RH, non-condensing Initial Set Accuracy 5% at 50% load Storage Temperature -20 C to +80 C Minimum Load No minimum load required Shock Able to survive 1 m drop onto concrete on Start Up Delay 2 s max each of 6 axes Start Up Rise Time 100 ms typical Vibration 10-300 Hz, 2 g 15 mins/sweep. 30 mins for Hold Up Time 5 ms typical at full load and 115 VAC each of 3 axes Line Regulation 0.5% max Load Regulation 2% max, 0-100% load EMC & Safety Transient Response 10% max. deviation, recovery to <1% Emissions EN55032, level B conducted & radiated within 500 s for a 50% step load change Harmonic Currents EN61000-3-2, class A at 0.2 A/s Voltage Flicker EN61000-3-3 Ripple & Noise See table ESD Immunity EN61000-4-2, 4kV contact, 8kV air, Overvoltage Protection See table Perf Criteria A Overload Protection 120-180%, auto recovery Radiated Immunity EN61000-4-3, 3 V/m, Perf Criteria A Short Circuit Protection Trip and restart (hiccup mode) EFT/Burst EN61000-4-4, level 2, Perf Criteria A Temperature 0.2 %/C Surge EN61000-4-5 installation class 3, Coefficient Perf Criteria A Conducted Immunity EN61000-4-6, 3 V, Perf Criteria A Magnetic Field EN61000-4-8, 1 A/m, Perf Criteria A Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals EN60950-1, cUL60950-1, IEC60950-1, EN62368-1, IEC62368-1, CE (Meets all applicable directives), UKCA (Meets all applicable legislation) AC-DCAC-DC VCP05 Models and Ratings (2) (1) (3) (4) Output Power Output Voltage Output Current Ripple & Noise OVP Setting Efficiency Model Number 5.0 W 5.0 V 1.0 A 150 mV 10.0 V 69% VCP05US05 4.8 W 12.0 V 0.4 A 150 mV 20.0 V 69% VCP05US12 4.5 W 15.0 V 0.3 A 150 mV 25.0 V 69% VCP05US15 Notes 1. Measured at DC output connector using 20 MHz bandwidth and 0.1 F ceramic capacitor in parallel with 10 F electrolytic capacitor placed at connector terminals 2. Other voltages between 3.0 V and 15.0 V are available, consult sales for details. 3. Typical trip point. 4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input. Mechanical Details 2.3 (58.5) 1.15 (29.25) 0.75 (19.1) 1.05 (26.7) 1 4 TOP VIEW 5 3 2 1.01 (25.7) 0.4 (10) 0.99 (25.2) 0.070 (1.80) Pin Designation 0.040 1 No connection (1.00) 2 Neutral 3 Live 4 Output -VE 5 Output +VE Notes 1. All dimensions are in inches (mm). 2. Weight: 0.04 lbs (20 g) approx. 3. Tolerance: x.x = 0.04 (x.x = 1.0), x.xx = 0.02 (x.xx = 0.5) 27 Oct 2021 0.06 (1.60) 0.18 (4.50) 0.05 0.19 (1.2) (4.8) 0.15 (3.80) 0.62 0.59 (15.8) (15) 0.67 1.4 (17.02) (35.5)