15 Watts xppower.com VCP Series Low Cost Output Voltages from 5 to 24 V PCB Mounting Open Frame & Encapsulated Versions IT & Medical Approvals Class II Construction No Load Input Power <0.3 W BRAND Specification Input General Input Voltage 90-264 VAC Efficiency See table Input Frequency 47-63 Hz Isolation 4000 VAC Input to Output Input Current 0.5 A max at 90 VAC Switching Frequency 132 kHz typical Inrush Current 40 A max at 240 VAC, cold start at 25 C MTBF 250 kHrs to MIL-HDBK-217F at 25 C, GB Power Factor EN61000-3-2, class A Environmental No Load Input Power <0.3 W Input Protection Internal T2.0A/250 V fuse in line Operating Temperature 0 C to +70 C, derate from 100% load at 50 C to 50% load at 70 C Cooling Natural convection Output Operating Humidity 5-90% RH, non-condensing Output Voltage See table Storage Temperature -20 C to +80 C Initial Set Accuracy 2% at 50% load Vibration 10-300 Hz, 2 g 15 mins/sweep. 30 mins for Minimum Load No minimum load required each of 3 axes Start Up Delay 2 s max Start Up Rise Time 100 ms typical EMC & Safety Hold Up Time 5 ms typical at full load and 115 VAC Emissions EN55032, level B conducted & radiated Line Regulation 0.5% max Harmonic Currents EN61000-3-2, class A Load Regulation 2% max, 0-100% load Voltage Flicker EN61000-3-3 Transient Response 10% max. deviation, recovery to <1% ESD Immunity EN61000-4-2, 4 kV indirect contact, within 500 s for a 50% step load change 8 kV air, Perf Criteria A at 0.2 A/s Radiated Immunity EN61000-4-3, 3 V/m, Perf Criteria A Ripple & Noise See table EFT/Burst EN61000-4-4, level 2, Perf Criteria A Overvoltage Protection See table Surge EN61000-4-5 installation class 3, Overload Protection 120-280 %, auto recovery Perf Criteria A Short Circuit Protection Trip and restart (hiccup mode) Conducted Immunity EN61000-4-6, 3 V, Perf Criteria A Temperature 0.2 %/C Magnetic Field EN61000-4-8, 1 A/m, Perf Criteria A Coefficient Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals EN60950-1, cUL60950-1, IEC60950-1, EN60601-1, cUL60601-1, IEC60601-1, EN62368-1, IEC62368-1, CE (Meets all applicable directives), UKCA (Meets all applicable legislation) AC-DCAC-DC VCP15 Models and Ratings (2) (1) (3) (5) (4) Output Power Output Voltage Output Current Ripple & Noise OVP Setting Efficiency Model Number 10 W 5.0 V 2.00 A 100 mV 10.0 V 74% VCP15US05 15 W 12.0 V 1.25 A 100 mV 20.0 V 82% VCP15US12 15 W 15.0 V 0.90 A 150 mV 25.0 V 83% VCP15US15 15 W 24.0 V 0.63 A 200 mV 35.0 V 84% VCP15US24 Notes 1. Measured at DC output connector using 20 MHz bandwidth and 0.1 F ceramic capacitor in parallel with 10 F electrolytic capacitor placed at connector terminals. 2. Other voltages between 5.0 V and 24 V are available, consult sales for details. 3. Typical trip point. 4. For encapsulated versions, add suffix -E to the model number e.g VCP15US24-E. 5. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input. Mechanical Details Open Frame Version Encapsulated Version (-E) 2.72 (69.0) 2.55 (65.0) 1.209 (30.7) 1.197 (30.4) 0.484 (12.3) 1.209 (30.7) 1.197 (30.4) 3 2 2 3 1 1 TOP VIEW TOP VIEW 4 4 5 5 0.819 (20.8) 0.484 (12.3) 0.819 (20.8) 1.205 (30.6) 1.205 (30.6) 1.27 (32.5) 0.070 (1.80) 0.04 0.04 (1.00) (1.00) Pin Designation 1 Live 2 Neutral 3 No connection 4 Output -VE 5 Output +VE Notes 1. All dimensions are in inches (mm). 3. Tolerance: x.xx = 0.04 (x.x = 0.1) x.xxx = 0.2 (x.xx = 0.5) 2. Weight: Open frame versions: 0.09 lbs (40 g) approx. Encapsulated versions: 0.22 lbs (100 g) approx. 27 Oct 2021 0.06 (1.60) 0.626 0.677 0.15 (3.80) (15.9) (17.2) 0.465 (11.8) 0.67 (17.0) 0.18 0.555 (4.50) 0.85 (21.50) (14.1) 1.49 (38) 1.24 (31.40) 1.65 (42.0) 0.626 (15.9) 1.11 (28.2) 0.465 (11.8) 0.677 (17.2) 0.555 (14.1) 0.15 (3.80) 0.67 (17.0)