xppower.com 24 Watts VCP Series Low Cost Output Voltages from 5 to 24 V PCB Mount Open Frame & Encapsulated Versions IT & Medical Approvals Class II Construction No Load Input Power <0.3 W BRAND Specification Input General Input Voltage 90-264 VAC Efficiency See table Input Frequency 47-63 Hz Isolation 4000 VAC Input to Output Input Current 0.6 A max at 90 VAC Switching Frequency 65 kHz typical Inrush Current 40 A max at 240 VAC, cold start at 25 C MTBF 250 kHrs to MIL-HDBK-217F at 25 C, GB Power Factor EN61000-3-2, class A Environmental No Load Input Power <0.3 W Input Protection Internal T2.0A/250 V fuse in line Operating Temperature 0 C to +70 C, derate from 100% load at 50 C to 50% load at 70 C Cooling Natural convection Output Operating Humidity 5-90% RH, non-condensing Output Voltage See table Storage Temperature -20 C to +80 C Initial Set Accuracy 2% at 50% load Vibration 10-300 Hz, 2 g 15 mins/sweep. 30 mins for Minimum Load No minimum load required each of 3 axes Start Up Delay 2 s max Start Up Rise Time 50 ms typical EMC & Safety Hold Up Time 5 ms typical at full load and 115 VAC Emissions EN55011/22, level B conducted & radiated Line Regulation 0.5% max Harmonic Currents EN61000-3-2, class A Load Regulation 2% max, 0-100% load Voltage Flicker EN61000-3-3 Transient Response 10% max. deviation, recovery to <1% ESD Immunity EN61000-4-2, 4kV indirect contact, within 500 s for a 50% step load change 8kV air, Perf Criteria A at 0.2 A/s Radiated Immunity EN61000-4-3, 3 V/m, Perf Criteria A Ripple & Noise See table EFT/Burst EN61000-4-4, level 2, Perf Criteria A Overvoltage Protection See table Surge EN61000-4-5, installation class 3, Overload Protection 120-280 %, auto recovery Perf Criteria A Short Circuit Protection Trip and restart (hiccup mode) Conducted Immunity EN61000-4-6, 3 V, Perf Criteria A Temperature 0.2 %/C Magnetic Field EN61000-4-8, 1 A/m, Perf Criteria A Coefficient Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals EN60950-1, cUL60950-1, IEC60950-1, EN60601-1, cUL60601-1, IEC60601-1 AC-DCAC-DC VCP24 Models and Ratings (2) (1) (3) (5) (4) Output Power Output Voltage Output Current Ripple & Noise OVP Setting Efficiency Model Number 12.5 W 5.0 V 2.5 A 100 mV 10.0 V 73% VCP24US05 24.0 W 12.0 V 2.0 A 100 mV 20.0 V 80% VCP24US12 24.0 W 15.0 V 1.6 A 150 mV 25.0 V 81% VCP24US15 24.0 W 24.0 V 1.0 A 200 mV 35.0 V 82% VCP24US24 Notes 1. Measured at DC output connectors using 20 MHz bandwidth and 0.1 F ceramic capacitor in parallel with 10 F electrolytic capacitor placed at connector terminals. 2. Other voltages between 5.0 V and 24.0 V are available, consult sales for details. 3. Typical trip point. 4. For encapsulated versions, add suffix -E to the model number, e.g. VCP24US12-E 5. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input. Mechanical Details Open Frame Version Encapsulated Version (-E) 2.91 (73.8) 1.45 (36.9) 1.39 (35.3) 1.04 (26.5) 0.80 (20.2) 1.39 (35.3) 0.80 (20.2) 5 2 1 5 2 1 TOP VIEW TOP VIEW 4 3 4 3 1.16 (29.5) 1.16 (29.5) 1.30 (33.1) 1.30 (33.1) 1.04 (26.5) 3.11 (79.0) 0.07 (1.8) 0.04 (1.0) 0.04 (1.0) Pin Designation 1 Live 2 Neutral 3 Output +VE 4 Output -VE 5 N/C Notes 1. All dimensions are in inches (mm). 2. Weight: open frame versions: 0.165 lbs (75 g) approx, encapsulated versions 0.32 lbs (150 g) approx. 3. Tolerance: x.xx = 0.04 (x.x = 0.1) x.xxx = 0.2 (x.xx = 0.5) 27-Jun-17 1.64 (41.6) 0.06 (1.6) 0.71 0.72 (18.0) (18.5) 0.15 (3.8) 0.18 (4.50) 0.68 (17.4) 0.76 (19.4) 1.15 (29.3) 0.72 1.12 (28.5) 0.71 (18.0) (18.5) 0.68 (17.4) 0.14 (3.8) 1.81 (46.0)