AC-DC Power Supplies VET36 Series 36 Watt Energy Efficiency Level VI xxx Series European CoC Tier 2 Universal Input Output Voltages from 12 V to 24 V Class II Construction Low Cost BRAND Dimensions: The VET36 series of desk-top power supplies comply with the very latest energy efficiency level VI VET36: standards with high active mode efficiency and extremely low no load power consumption. 4.53 x 1.89 x 1.28 (115.0 x 48.0 x 32.5 mm) Available with a standard jack plug connector these adaptors suit a wide variety of cost sensitive applications while maintaining industry leading performance. Models & Ratings (2) Output Power Output Voltage Output Current Total Regulation Output Connector Model Number (3) 12.0 V 3000 mA 5% 5.5 x 2.1 x 12 mm DC Jack VET36US120C2-JA (4) 15.0 V 2400 mA 5% 5.5 x 2.1 x 12 mm DC Jack VET36US150C2-JA 36 W (4) 18.0 V 2000 mA 5% 5.5 x 2.1 x 12 mm DC Jack VET36US180C2-JA (4) 24.0 V 1500 mA 5% 5.5 x 2.1 x 12 mm DC Jack VET36US240C2-JA Notes 1. Other output voltages available, contact sales for details. 3. Meets DOE efficiency level VI and CoC tier 1. 2. Total regulation includes initial set accuracy, line and load regulation. 4. Meets DOE efficiency level VI and CoC tier 2. Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC Input Frequency 47 63 Hz Input Current 0.8 A 100 VAC Inrush Current 120 A 240 VAC, cold start at 25 C Power Factor EN61000-3-2, class A No Load Input Power 75 mW Input Protection Internal T1.0A/250 VAC fuse Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 24 V See Models and Ratings table Minimum Load 0 A No minimum load required Start Up Delay 4 s Start Up Rise Time 30 ms Hold Up Time 8 ms Full load and 100 VAC Total Regulation 5 % See Models and Ratings table Recovely within <1% within 500 s for a 50% step load Transient Response 5 % deviation change at 0.15 A/s Measured with 20 MHz bandwidth and 47 F electrolytic in Ripple & Noise 180 mV pk-pk parallel with 0.1 F ceramic capacitor Short Circuit Protection Continuous, trip and restart (hiccup mode) with auto recovery Temperature Coefficient 0.05 %/ C www.xppower.com 1AC-DC Power Supplies VET36 Series General Characteristic Minimum Typical Maximum Units Notes & Conditions Typical average of efficiencies measured at 25%, 50%, 75% Efficiency 87 % and 100% load and 115 VAC input Energy Efficiency Level VI Isolation 3000 VAC Input to Output Switching Frequency 24 70 kHz Variable Mean Time Between Failure 250 kHrs MIL-HDBK-217F at 25 C GB Weight 0.36 (165.0) lb (g) Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 C Derate from 100% load at 45 C to 50% load at 60 C Storage Temperature -40 +85 C Operating Humidity 5 95 % RH, non-condensing Cooling Natural convection Shock 1 m drop onto concrete on each of 6 axes Vibration 10 300 Hz 2 g 15 mins/sweep, 60 mins for each of 3 axes EMC: Emissions Phenomenon Standard Test Level Notes & Conditions Conducted EN55032 Level B Radiated EN55032 Level B Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 EMC: Immunity Phenomenon Standard Test Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 4 kV contact, 8 kV air A Radiated Immunity EN61000-4-3 3 V/m A EFT/Burst EN61000-4-4 Level 2 A Surge EN61000-4-5 Level 2 A Conducted Immunity EN61000-4-6 3 V A Magnetic Fields EN61000-4-8 1 A/m A 100% U (0 VAC) for 10 ms A T EN55024 (115VAC) 30% U (80.5 VAC) for 500 ms A T 100% U (0 VAC) for 5000 ms B T Dips and Interruptions 100% U (0 VAC) for 10 ms A T EN55024 (230VAC) 30% U (161 VAC) for 500 ms A T 100% U (0 VAC) for 5000 ms B T Safety Approvals Phenomenon Standard CB Report IEC60950-1, IEC62368-1 UL UL/cUL60950-1, approved as limited power source (LPS), UL62368-1 TUV EN60950-1, EN62368-1 CCC China Compulsory Certification GB4943 AU/NZ AU/NZ 60950.1 www.xppower.com 2