2-CHANNEL RADIO RECEIVER ROP-02 MANUAL INSTRUCTION CONNECTION MOUNTING 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnec- tor combined to the proper circuit. 2. Check if there is no voltage on connection cables by means of a special measure equipment. ZAMEL Sp. z o.o. 3. Connect the cables with the terminals in ac- cordance with the installing diagram. 4. Install ROP-02 device in installation cable box. ul. Zielona 27, 43-200 Pszczyna, Poland tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 5. Switch on the power supply from the mains. www.zamelcet.com, e-mail: marketing zamel.pl DESCRIPTION TECHNICAL DATA CAPACITY Radio receivers are used both as ele- ROP-02 ments in mounting in flush and surface in- Input (supply) terminals: L, N stallation cable boxes and as an actuator 750W 500W Input rated voltage: 230 V AC built directly in lighting fittings and other Input voltage tolerance: -15 +10 % receivers. ROP-02 enables operation in 5 different modes (switching on, switch- Nominal frequency: 50 / 60 Hz 250W 375W ing off, monostable mode, bistable mode, 0,39 W stand-by mode/ time mode). Nominal power consumption: 0,69 W operation mode 1 channel/ 1,09 W operation mode 2 channels/ APPLICATION Number of operation modes: 5 Number of channels: 1 Transmission: radio 868,32 MHz FEATURES Transmission way: unidirectional Coding: addressing transmission cooperation with wireless EXTA FREE Maximum number of transmitters: 32 control system transmitters, 2 output relays (voltage contacts 230V AC), Range: up to 250 m in the open area lighting, heating etc. operation control, Time adjustment: 1 second 18 hours (every 1 sec.) easy junction box 60 mm installation, Optical signalling of transmitters operation: LED red diode 5 operation modes: switching on, switch- Input terminals: IN1, IN2 ing off, monostable mode, bistable mode, Transmitters input (supply) terminals: OUT1, OUT2 - voltage output time mode (switch off delay), wide operation range (up to 230 m), Relay contact parameters: 2NO 5A / 250V AC AC1 1250 VA (voltage contact) operation is optically signalled, Number of terminal clamps: 6 low current consumption, possibility of 2 Section of connecting cables: up to 2,5 mm constant operation, o Ambient temperature range: -10 +55 C possibility of increasing operation range Operating position: free by means of RTN-01 retransmitter. Casing mounting: easy junction box 60 mm installation Casing protection degree: IP20 (EN 60529) Protection level: II Overvoltage category: II Pollution degree: 2 Surge voltage: 1 kV (EN 61000-4-5) The device is designed Dimensions: 47,5 x 47,5 x 20 mm for single-phase installa- tion and must be installed Weight: 0,039 kg in accordance with stand- Reference standard: EN 60669, EN 60950, EN 61000 ards valid in a particular country. The device should CAUTION be connected according to APPEARANCE the details included in this operating manual. Installation, connection and control should be carried out by a quali- Input terminals (IN1, IN2) 2-channel radio receiver ROP-01 operates as a receiver of 8-channel remote control- fied electrician staff, who act in accordance ler P-256/8 and of 2-channel button radio transmitter RNK-02 (light sources switch with the service manual and the device func- The ZAMEL company devices on/switch off control). The above mentioned transmitters can also control operation tions. Disassembling of the device is equal Output terminals (OUT1, OUT2) which are characterised with this with a loss of guarantee and can cause elec- of remote control socket RWG-01. sign can cooperate with each other. tric shock. Before installation make sure the connection cables are not under voltage. The Input (supply) terminals (L, N) cruciform head screwdriver 3,5 mm should be used to instal the device. Improper transport, WARRANTY CARD storage, and use of the device influence its wrong functioning. It is not advisable to instal There is 24 months guarantee on the product the device in the following cases: if any device 1. ZAMEL provides a two-year warranty for its products. Optical signalling of receivers operation part is missing or the device is damaged or de- 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances formed. In case of improper functioning of the b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- Programming buttons device contact the producer. TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear) 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. The symbol means selective 4. ZAMEL will review complaints in accordance with existing regulations. collecting of electrical and electronic 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. It is forbidden to put between the goods and the contract. the used equipment together with other waste. Salesman stamp and signature, date of sale VER. 005 20.05.2011OPERATION RADIO TRANSMITTERS POGRAMMING - CHANNEL 2 The device can operate in five modes: MONOSTABLE BISTABLE SWITCH ON TIME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ters push-button. status cyclically always button. adjusted time (tp), Press PROG push-button of ROP-02 device for a longer time till LED red diode switches on Choose one out of five ROP-02 operating after pressing the same push- SWITCH OFF but it may be switched off before (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red modes and programme the device in the same button. the device switches off adjusted time finishes. Default diode switches on (first signal pulsates, next the signal is constant). way as for channel 1. after pressing the push- settings - 15 seconds. CAUTION: For the monostable mode, press the button on the remote before pressing PROG push-button. button. CAUTION Adjusted time can not be deleted. TIME PROGRAMMING Press PROG push-button of ROP-02 device for a longer time till LED red diode switches on Wait again (for about 5 seconds) till (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red LED red diode switches on (first signal diode switches on (first signal pulsates, next the signal is constant). pulsates, next the signal is constant). RADIO TRANSMITTERS POGRAMMING - CHANNEL 1 1s 2s ns MONOSTABLE mode: for CHANNEL 1 Press PROG push-button of ROP-02 device After the adjusted time is finished and then release it. LED red diode switches off (the number of LED red diode flashes) and then switches on (signal pulsates). press PROG push-button Every LED diode pulse equals 1 second. and then release it - TIME IS ADDED. Press transmitters Press PROG push-button of ROP-02 device Release transmitters Press the same transmitters push- push-button for for a longer time until LED red diode switches on push-button. LED red diode -button and release it. LED red dio- 1s 2s ns a longer time. (constant signal). Next release PROG push-button. switches on (first signal de switches on (the signal pulsates) pulsates, next the signal is and next the signal switches off - for constant). THE TRANSMITTER IS ADDED. CHANNEL 2 BISTABLE mode: Wait again (for about 5 seconds) Press PROG push-button of ROP-02 device After the adjusted time is finished till LED red diode switches on and then release it. LED red diode switches off (the number of LED red diode flashes) (first signal pulsates, and then switches on (signal pulsates). press PROG push-button and then next the signal is constant). Every LED diode pulse equals 1 second. release it - TIME IS ADDED. Maximum time is 18 hours for every channel. Press PROG push-button of ROP-02 device Press the transmitters push-button Release transmitters push-button. RADIO TRANSMITTERS DELETION for a longer time until LED red diode switches on for a longer time. LED red diode switches LED red diode switches on (the (constant signal). Next release PROG push-button. on (first signal pulsates, next the signal is signal pulsates), next the LED red constant). diode switches off - it means the TRANSMITTER IS ADDED. SWITCH ON/SWITCH OFF mode (two push-buttons): Press PROG push-button of ROP-02 device After 5 seconds LED red diode switches on Release the push-button in ROP-02 - for a longer time. (signal pulsates) and then it switches off. MEMORY IS DELETED COOPERATION AND OPERATION RANGE Press PROG push-button of ROP-02 device Press and release transmitters push- Press and release the second transmitters for a longer time until LED red diode switches on button. LED red diode switches on push-button. LED red diode switches on Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 (constant signal). Next release PROG push-button. (first signal pulsates, next the signal is (the signal pulsates) and next it switches RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m constant). off - THE TRANSMITTER IS ADDED. RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m TIME MODE (one push-button): P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m Press PROG push-button of ROP-02 device Press and release transmitters push- Press and release the same transmitters RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m for a longer time till LED red diode switches on button. LED red diode switches on push-button. LED red diode RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m (constant signal). Next release PROG push-button. (the signal pulsates, next the signal is switches on (the signal pulsates) RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m constant). and next it switches off - RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m THE TRANSMITTER IS ADDED. An exemplary programming procedure with the use of P-257/2 remote controller. * - 1-channel transmitters do not cooperate with roller blinds controllers. The procedure for the rest of radio EXTA FREE transmitters is analogous. CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plaster - from 5 to 20, bricks - from 10 to 40 %, reinforced concrete - from 40 to 80 %, metal - from 90 to 100%, CAUTION: Every transmitter can cooperate with ROP-02 in a different mode, depending on how they were added to the device. glass - from 10 to 20 %. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. have also a negative influence on the range. VER. 005 20.05.2011