RZB-04 WIRELESS CONTROL SET CONNECTION ROP-02 MOUNTING - LIGHTING, 2-CHANNEL MANUAL INSTRUCTION 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector combined to the proper circuit. 2. Check if there is no voltage on connec- tion cables by means of a special measure equipment. ZAMEL Sp. z o.o. 3. Connect the cables with the terminals in ac- cordance with the installing diagram. 4. Install ROP-02 device in installation cable box. ul. Zielona 27, 43-200 Pszczyna, Poland 5. Switch on the power supply from the mains. tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing zamel.pl DESCRIPTION TECHNICAL DATA RNK-04 ROP-02 CAPACITY RNK-04 FUNCTIONING, MOUNTING Radio flush receivers are used both as Input (supply) terminals: - L, N elements in mounting in flush and surface By pressing the button, the transmitter sends installation cable boxes and as an actuator Input rated voltage: 3 V DC (CR2032 battery) 230 V AC 750W 500W a signal with 868,32 MHz frequency which con- built directly in lighting fitting casings and Battery life: 3 5 years - trols EXTA FREE receivers. Device program- other receivers). ROP-02 enables operation Input voltage tolerance: - -15 +10 % ming procedure (adding a transmitter to 250W 375W in 5 different modes (switching on, switching a receivers memory) is described in par- Nominal frequency: - 50 / 60 Hz off, monostable mode, bistable mode, time ticular EXTA FREE manual instructions. Nominal power consumption: - 0,39 W (stand-by mode) / 0,69 W mode. The device range (up to 250 m depending on operation mode 1 channel / 1,09 W a receiver) can be increased by means of a re- operation mode 2 channels APPLICATION transmitter or few RTN-01 retransmitters. The Number of operation modes: - 5 device can be mounted in any place by means Number of channels: 4 2 of double -sided adhesive tape or wall plugs Transmission: radio 868,32 MHz FEATURES 5 x (3 x 30) mm. Coding way: unidirectional complete set of wireless control (4chan- Coding:: addressing transmission Mounting by means of wall plugs: nel button radio transmitter RNK-04 and 1. Remove the button - to do it press the but- Maximum number of remote controls: - 32 2-channel radio flush receiver ROP-02). ton on one side, and on the other side put Range: up to 250 m in the open area a screwdriver into a slot and lift up the button. 2 output relays (dry contacts 230V AC), Time adjustment: - 1 sec 18 hours (every 1 sec) 2. Find a place on the wall to mount the lighting, heating operation control, other Optic signalling of transmitters operation: LED red diode transmitter, make two holes corresponding receivers control, Input terminals: - IN1, IN2 mounting holes from the transmitter s base. easy flush installation 60 mm, 3. Set wall plugs in the holes. 5 operation modes: switching on, switch- Transmitters input (supply) terminals: - OUT1, OUT2 (voltage contacts) 4. Fix the base by means of screwing screws ing off, monostable mode, bistable mode, Relay contact parameters: - 2NO 5A / 250V AC AC1 1250 VA into wall plugs. time mode (switch off delay), Number of terminal clamps: - 6 5. Place the button again. wide operation range (up to 200 m), 2 Section of connecting cables: - up to 2,5 mm operation is optically signalled, o Ambient temperature range: -10 +55 C BATTERY CHANGE low current consumption, possibility of Battery discharge status is signalled by Operating position: free constant operation, several LED red diode flashes during Casing mounting: wall plugs, double-sided adhesive tape installation cable box 60 mm possibility of increasing operation range transmission time. by means of RTN-01 retransmitter. Casing protection degree: IP20 (EN 60529) 1. Remove the button (mounting - point 1). Protection level: III II 2. By means of a screwdriver lever up the Overvoltage category: - II printed-circuit board releasing the bottom latch and remove it from the base. Pollution degree: - 2 3. Remove the battery from the latch. Surge voltage: - 1 kV (EN 61000-4-5) 4. Mount a new battery. Watch battery polari- Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm 2-channel radio flush receiver ROP-02 sation marked on the latch. Wrong battery T h e dev i c e i s de si gne d f o r Weight: 0,038 kg 0,039 kg operates as a receiver of 8-channel remote mounting may cause device damage. s in g l e - p ha s e in st allat i o n an d Reference standard: ETSI EN 300 220-1, EN 60669, EN 60950, 5. Put the removed printed-circuit board back controller P-256/8 and of 4-channel button must be installed in accord- ETSI EN 300 220-2 EN 61000 in the base. radio transmitter RNK-04 (light sources anc e w it h st an dar d s val i d in 6. Put back the button. switch on/switch off control). The above a par t i c ular c o unt r y. T h e de- mentioned transmitters can also control v i c e sh o uld be c onn ec ted APPEARANCE CAUTION: While changing the battery, CAUTION ac c o r din g to t h e det ails in- operation of radio lighting switch RWL-01 it is suggested to press any of the buttons c l u d e d in t h i s o p e r at in g m an ual. I n st a llat i o n, and remote control socket RWG-01. Input terminals (IN1, IN2) c onn ec t i on an d c ont r o l sh o uld be c a r r ied o ut by for about 5 seconds before putting it into The ZAMEL company devices a quali fi e d e l e c t r i c ian st af f, w h o ac t in ac c o r d- a latch. Next press transmission button Output terminals (OUT1, OUT2) which are characterised anc e w it h t h e s e r v i c e m anual an d t h e dev i c e several times to check its operation. If the with this sign can cooperate functions. transmitter does not work properly repeat Input (supply) terminals (L, N) with each other. In c ase of c asing dismant ling an elec t ric sho c k the battery change procedure. m ay o c c ur, an d t h e guar ante e i s l o st t h e n. B e- fore installation make sure the c onnection c a- Optic signalling of receiver s operation b l e s are n ot un de r vo lt ag e. T h e c r uc i fo r m h e ad WARRANTY CARD screwdriver 3,5 mm should be used to instal the Programming push-button dev i c e. Imp r o p e r t r ansp o r t , sto r ag e, an d us e Optic signalling There is 24 months guarantee on the product of t h e dev i c e in fl u e nc e it s w r o n g f unc t i o nin g. 1. ZAMEL provides a two-year warranty for its products. It i s n ot adv i s ab l e to inst al t h e dev i c e in t h e of transmitters operation 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances following c ases: if any devic e par t is missing or b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- t h e dev i c e i s dam ag e d o r defo r m e d. In c as e of Push-buttons TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting imp r o p e r f unc t i o nin g of t h e dev i c e c o nt ac t t h e from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device producer. in the moment of sale (if they appear) 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. The symbol means selective 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. collecting of electrical and electronic 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. It is forbidden to put the used between the goods and the contract. equipment together with other waste. Salesman stamp and signature, date of sale VER. 003 20.05.2011ROP-02 OPERATION RADIO TRANSMITTERS PROGRAMMING - CHANNEL 2 ROP-02 can operate in five modes for every channel: MONOSTABLE BISTABLE SWITCH ON TIME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ter s push-button. status cyclically always button. adjusted time (tp), Press PROG push-button of ROP-02 device for a longer time until LED red diode switches Choose one of ROP-02 five operation modes after pressing the same push- SWITCH OFF but it may be switched off before on (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red and programme the device in the same way as button. the device switches off adjusted time finishes. Default diode switches on (first signal pulsates, next the signal is constant). for channel 1. after pressing the push- settings - 15 seconds. CAUTION: For the monostable mode, press the button on the remote before pressing PROG push-button. button. CAUTION Adjusted time can not be deleted. TIME PROGRAMMING Press PROG push-button of ROP-02 device for a longer time till LED red diode switches on Wait again (for about 5 seconds) till (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red LED red diode switches on (first signal diode switches on (first signal pulsates, next the signal is constant). pulsates, next the signal is constant). RADIO TRANSMITTERS PROGRAMMING - CHANNEL 1 1s 2s ns MONOSTABLE mode: for CHANNEL 1 Press PROG push-button of ROP-02 device and After the adjusted time is finished (the then release it. LED red diode switches off and number of LED red diode flashes) press then switches on (signal pulsates). Every LED PROG push-button and then release it - diode pulse equals 1 second. TIME IS ADDED. Press transmitters Press PROG push-button of ROP-02 device Release transmitter s push- Press the same transmitter s push- push-button for for a longer time until LED red diode switches on button. LED red diode switches -button and release it. LED red 1s 2s ns a longer time. (constant signal). Next release PROG push-button. on (first signal pulsates, next diode switches on (the signal pulsa- the signal is constant). tes) and next it switches off - THE for TRANSMITTER IS ADDED. CHANNEL 2 BISTABLE mode: Wait again - third time (for about 5 Press PROG push-button of ROP-02 device After the adjusted time is finished seconds) till LED red diode and then release it. LED red diode switches off (the number of LED red diode flashes) switches on (first signal pulsates, and then switches on (signal pulsates). Every press PROG push-button and then next the signal is constant). LED diode pulse equals 1 second. release it - TIME IS ADDED. Maximum time is 18 hours. Press PROG push-button of ROP-02 device Press the transmitter s push-button Release transmitters RADIO TRANSMITTERS DELETION for a longer time until LED red diode for a longer time. LED red diode push-button. LED red diode switches switches on (constant signal). switches on (first signal pulsates, on (the signal pulsates), next the LED Next release PROG push-button. next the signal is constant). red diode switches off - it means the TRANSMITTER IS ADDED. SWITCH ON/SWITCH OFF mode (two push-buttons): Press PROG push-button of ROP-02 device After 5 seconds LED red diode switches on Release the push-button in ROP-02 - for a longer time. (signal pulsates) and then it switches off. MEMORY IS DELETED. COOPERATION AND OPERATING RANGE Press PROG push-button of ROP-02 device Press and release transmitter s first Press and release the second transmitter s for a longer time until LED red diode push-button. LED red diode switches on push-button. LED red diode switches on Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 switches on (constant signal). (first signal pulsates, (the signal pulsates) and next it switches RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Next release PROG push-button. next the signal is constant). off - THE TRANSMITTER IS ADDED. RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m TIME mode (one push-button): P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m Press PROG push-button of ROP-02 device Press PROG push-button of ROP-01 Press and release the same transmitter s RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m for a longer time till LED red diode device and then release it. LED red diode push-buton. LED red diode switches on RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m switches on (constant signal). switches on (first signal pulsates, (signal pulsates) and then switches off - RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m Next release PROG push-button. next the signal is constant). THE TRANSMITTER IS ADDED. RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m * - 1-channel transmitters do not cooperate with roller blind controllers. An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE transmitters CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100% , is analogous. CAUTION: Every transmitter can cooperate with ROP-02 in a different mode, depending on how they were added to glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. also a negative influence on the range. VER. 003 20.05.2011