X-On Electronics has gained recognition as a prominent supplier of RZB-04 Power Management IC Development Tools across the USA, India, Europe, Australia, and various other global locations. RZB-04 Power Management IC Development Tools are a product manufactured by Zamel. We provide cost-effective solutions for Power Management IC Development Tools, ensuring timely deliveries around the world.

RZB-04 Zamel

RZB-04 electronic component of Zamel
Images are for reference only
See Product Specifications
Part No.RZB-04
Manufacturer: Zamel
Category: Power Management IC Development Tools
Description: Wireless control set; EXTA FREE; IP20; -10÷55°C; 868.32MHz
Datasheet: RZB-04 Datasheet (PDF)
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 46.5335 ea
Line Total: USD 46.53

Availability - 0
MOQ: 1  Multiples: 1
Pack Size: 1
   
Manufacturer
Product Category
Series
Kit Contents
Ip Rating
Type Of Module
Operating Temperature
Frequency
LoadingGif
 
Notes:- Show Stocked Products With Similar Attributes.

We are delighted to provide the RZB-04 from our Power Management IC Development Tools category, at competitive rates not only in the United States, Australia, and India, but also across Europe and beyond. A long established and extensive electronic component distribution network has enhanced our global reach and dependability, ensuring cost savings through prompt deliveries worldwide. Client satisfaction is at the heart of our business, where every component counts and every customer matters. Our technical service team is ready to assist you. From product selection to after-sales support, we strive to deliver a seamless and satisfying experience. Are you ready to experience the best in electronic component distribution? Contact X-ON Electronics today and discover why X-On are a preferred choice for the RZB-04 and other electronic components in the Power Management IC Development Tools category and beyond.

Image Part-Description
Stock Image SDM-10
Timer; Range:1 year; 230VAC; DIN; IP20; 14VA; 90x35x66mm; 16A
Stock : 9
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SEM-01
Converter: signal separator; DIN; IP20; 90x17.5x66mm; -20÷45°C
Stock : 6
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SOH-01
Probe light; Works with: WZM-01,WZM-02,WZN-01; 1m
Stock : 19
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image RZB-05
Wireless control set; EXTA FREE; IP20; -10÷55°C; 868.32MHz
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SOH-03
Probe light; Works with: WZM-01,WZM-02,WZN-01; 3m
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SLW-01
RGB controller; SUPLA; IP20; 12÷24VDC; canned; -10÷55°C; OUT1:2A
Stock : 4
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SBW-01
Gate controller; SUPLA; IP20; 24VAC; 24VDC; flush mount; -20÷55°C
Stock : 3
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SBW-02
Gate controller; SUPLA; IP20; 12÷24VAC; 12÷24VDC; flush mount
Stock : 5
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SDM-10/U
Timer; Range:1 year; 24÷250VAC; 30÷300VDC; DIN; IP20; 14VA; 16A
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SLW-02
LED controller; SUPLA; IP20; 12÷24VDC; flush mount; -10÷55°C; IN:1
Stock : 3
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Image Part-Description
Stock Image RZB-05
Wireless control set; EXTA FREE; IP20; -10÷55°C; 868.32MHz
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EN63A0QI-E
EN63A0QI DC to DC Converter and Switching Regulator Chip 1.02VDC/1.2VDC/1.8VDC Output Evaluation Board
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image ENERGY-HARVEST-RD
C8051F342, Si1012, Si4431 Energy Harvesting Power Management Evaluation Board
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SCO-802
Dimmer; 230VAC; in mounting box; 1.5A; -25÷50°C; 350W
Stock : 4
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SCO-812
Dimmer; 230VAC; DIN; 1.5A; -25÷50°C; 350W; Leads: screw terminals
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 63-23-112-4
Power Conditioning 120VA 120V OUT
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SHIELD_BTS50015-1TAD
Power Management IC Development Tools
Stock : 11
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SI8239XISO-KIT
Power Management IC Development Tools Si8239x Evaluation kit
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SI8274ISO-KIT
Power Management IC Development Tools SI8274/71 EVAL KIT
Stock : 6
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.

RZB-04 WIRELESS CONTROL SET CONNECTION ROP-02 MOUNTING - LIGHTING, 2-CHANNEL MANUAL INSTRUCTION 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector combined to the proper circuit. 2. Check if there is no voltage on connec- tion cables by means of a special measure equipment. ZAMEL Sp. z o.o. 3. Connect the cables with the terminals in ac- cordance with the installing diagram. 4. Install ROP-02 device in installation cable box. ul. Zielona 27, 43-200 Pszczyna, Poland 5. Switch on the power supply from the mains. tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing zamel.pl DESCRIPTION TECHNICAL DATA RNK-04 ROP-02 CAPACITY RNK-04 FUNCTIONING, MOUNTING Radio flush receivers are used both as Input (supply) terminals: - L, N elements in mounting in flush and surface By pressing the button, the transmitter sends installation cable boxes and as an actuator Input rated voltage: 3 V DC (CR2032 battery) 230 V AC 750W 500W a signal with 868,32 MHz frequency which con- built directly in lighting fitting casings and Battery life: 3 5 years - trols EXTA FREE receivers. Device program- other receivers). ROP-02 enables operation Input voltage tolerance: - -15 +10 % ming procedure (adding a transmitter to 250W 375W in 5 different modes (switching on, switching a receivers memory) is described in par- Nominal frequency: - 50 / 60 Hz off, monostable mode, bistable mode, time ticular EXTA FREE manual instructions. Nominal power consumption: - 0,39 W (stand-by mode) / 0,69 W mode. The device range (up to 250 m depending on operation mode 1 channel / 1,09 W a receiver) can be increased by means of a re- operation mode 2 channels APPLICATION transmitter or few RTN-01 retransmitters. The Number of operation modes: - 5 device can be mounted in any place by means Number of channels: 4 2 of double -sided adhesive tape or wall plugs Transmission: radio 868,32 MHz FEATURES 5 x (3 x 30) mm. Coding way: unidirectional complete set of wireless control (4chan- Coding:: addressing transmission Mounting by means of wall plugs: nel button radio transmitter RNK-04 and 1. Remove the button - to do it press the but- Maximum number of remote controls: - 32 2-channel radio flush receiver ROP-02). ton on one side, and on the other side put Range: up to 250 m in the open area a screwdriver into a slot and lift up the button. 2 output relays (dry contacts 230V AC), Time adjustment: - 1 sec 18 hours (every 1 sec) 2. Find a place on the wall to mount the lighting, heating operation control, other Optic signalling of transmitters operation: LED red diode transmitter, make two holes corresponding receivers control, Input terminals: - IN1, IN2 mounting holes from the transmitter s base. easy flush installation 60 mm, 3. Set wall plugs in the holes. 5 operation modes: switching on, switch- Transmitters input (supply) terminals: - OUT1, OUT2 (voltage contacts) 4. Fix the base by means of screwing screws ing off, monostable mode, bistable mode, Relay contact parameters: - 2NO 5A / 250V AC AC1 1250 VA into wall plugs. time mode (switch off delay), Number of terminal clamps: - 6 5. Place the button again. wide operation range (up to 200 m), 2 Section of connecting cables: - up to 2,5 mm operation is optically signalled, o Ambient temperature range: -10 +55 C BATTERY CHANGE low current consumption, possibility of Battery discharge status is signalled by Operating position: free constant operation, several LED red diode flashes during Casing mounting: wall plugs, double-sided adhesive tape installation cable box 60 mm possibility of increasing operation range transmission time. by means of RTN-01 retransmitter. Casing protection degree: IP20 (EN 60529) 1. Remove the button (mounting - point 1). Protection level: III II 2. By means of a screwdriver lever up the Overvoltage category: - II printed-circuit board releasing the bottom latch and remove it from the base. Pollution degree: - 2 3. Remove the battery from the latch. Surge voltage: - 1 kV (EN 61000-4-5) 4. Mount a new battery. Watch battery polari- Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm 2-channel radio flush receiver ROP-02 sation marked on the latch. Wrong battery T h e dev i c e i s de si gne d f o r Weight: 0,038 kg 0,039 kg operates as a receiver of 8-channel remote mounting may cause device damage. s in g l e - p ha s e in st allat i o n an d Reference standard: ETSI EN 300 220-1, EN 60669, EN 60950, 5. Put the removed printed-circuit board back controller P-256/8 and of 4-channel button must be installed in accord- ETSI EN 300 220-2 EN 61000 in the base. radio transmitter RNK-04 (light sources anc e w it h st an dar d s val i d in 6. Put back the button. switch on/switch off control). The above a par t i c ular c o unt r y. T h e de- mentioned transmitters can also control v i c e sh o uld be c onn ec ted APPEARANCE CAUTION: While changing the battery, CAUTION ac c o r din g to t h e det ails in- operation of radio lighting switch RWL-01 it is suggested to press any of the buttons c l u d e d in t h i s o p e r at in g m an ual. I n st a llat i o n, and remote control socket RWG-01. Input terminals (IN1, IN2) c onn ec t i on an d c ont r o l sh o uld be c a r r ied o ut by for about 5 seconds before putting it into The ZAMEL company devices a quali fi e d e l e c t r i c ian st af f, w h o ac t in ac c o r d- a latch. Next press transmission button Output terminals (OUT1, OUT2) which are characterised anc e w it h t h e s e r v i c e m anual an d t h e dev i c e several times to check its operation. If the with this sign can cooperate functions. transmitter does not work properly repeat Input (supply) terminals (L, N) with each other. In c ase of c asing dismant ling an elec t ric sho c k the battery change procedure. m ay o c c ur, an d t h e guar ante e i s l o st t h e n. B e- fore installation make sure the c onnection c a- Optic signalling of receiver s operation b l e s are n ot un de r vo lt ag e. T h e c r uc i fo r m h e ad WARRANTY CARD screwdriver 3,5 mm should be used to instal the Programming push-button dev i c e. Imp r o p e r t r ansp o r t , sto r ag e, an d us e Optic signalling There is 24 months guarantee on the product of t h e dev i c e in fl u e nc e it s w r o n g f unc t i o nin g. 1. ZAMEL provides a two-year warranty for its products. It i s n ot adv i s ab l e to inst al t h e dev i c e in t h e of transmitters operation 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances following c ases: if any devic e par t is missing or b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- t h e dev i c e i s dam ag e d o r defo r m e d. In c as e of Push-buttons TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting imp r o p e r f unc t i o nin g of t h e dev i c e c o nt ac t t h e from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device producer. in the moment of sale (if they appear) 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. The symbol means selective 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. collecting of electrical and electronic 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. It is forbidden to put the used between the goods and the contract. equipment together with other waste. Salesman stamp and signature, date of sale VER. 003 20.05.2011ROP-02 OPERATION RADIO TRANSMITTERS PROGRAMMING - CHANNEL 2 ROP-02 can operate in five modes for every channel: MONOSTABLE BISTABLE SWITCH ON TIME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ter s push-button. status cyclically always button. adjusted time (tp), Press PROG push-button of ROP-02 device for a longer time until LED red diode switches Choose one of ROP-02 five operation modes after pressing the same push- SWITCH OFF but it may be switched off before on (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red and programme the device in the same way as button. the device switches off adjusted time finishes. Default diode switches on (first signal pulsates, next the signal is constant). for channel 1. after pressing the push- settings - 15 seconds. CAUTION: For the monostable mode, press the button on the remote before pressing PROG push-button. button. CAUTION Adjusted time can not be deleted. TIME PROGRAMMING Press PROG push-button of ROP-02 device for a longer time till LED red diode switches on Wait again (for about 5 seconds) till (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red LED red diode switches on (first signal diode switches on (first signal pulsates, next the signal is constant). pulsates, next the signal is constant). RADIO TRANSMITTERS PROGRAMMING - CHANNEL 1 1s 2s ns MONOSTABLE mode: for CHANNEL 1 Press PROG push-button of ROP-02 device and After the adjusted time is finished (the then release it. LED red diode switches off and number of LED red diode flashes) press then switches on (signal pulsates). Every LED PROG push-button and then release it - diode pulse equals 1 second. TIME IS ADDED. Press transmitters Press PROG push-button of ROP-02 device Release transmitter s push- Press the same transmitter s push- push-button for for a longer time until LED red diode switches on button. LED red diode switches -button and release it. LED red 1s 2s ns a longer time. (constant signal). Next release PROG push-button. on (first signal pulsates, next diode switches on (the signal pulsa- the signal is constant). tes) and next it switches off - THE for TRANSMITTER IS ADDED. CHANNEL 2 BISTABLE mode: Wait again - third time (for about 5 Press PROG push-button of ROP-02 device After the adjusted time is finished seconds) till LED red diode and then release it. LED red diode switches off (the number of LED red diode flashes) switches on (first signal pulsates, and then switches on (signal pulsates). Every press PROG push-button and then next the signal is constant). LED diode pulse equals 1 second. release it - TIME IS ADDED. Maximum time is 18 hours. Press PROG push-button of ROP-02 device Press the transmitter s push-button Release transmitters RADIO TRANSMITTERS DELETION for a longer time until LED red diode for a longer time. LED red diode push-button. LED red diode switches switches on (constant signal). switches on (first signal pulsates, on (the signal pulsates), next the LED Next release PROG push-button. next the signal is constant). red diode switches off - it means the TRANSMITTER IS ADDED. SWITCH ON/SWITCH OFF mode (two push-buttons): Press PROG push-button of ROP-02 device After 5 seconds LED red diode switches on Release the push-button in ROP-02 - for a longer time. (signal pulsates) and then it switches off. MEMORY IS DELETED. COOPERATION AND OPERATING RANGE Press PROG push-button of ROP-02 device Press and release transmitter s first Press and release the second transmitter s for a longer time until LED red diode push-button. LED red diode switches on push-button. LED red diode switches on Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 switches on (constant signal). (first signal pulsates, (the signal pulsates) and next it switches RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Next release PROG push-button. next the signal is constant). off - THE TRANSMITTER IS ADDED. RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m TIME mode (one push-button): P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m Press PROG push-button of ROP-02 device Press PROG push-button of ROP-01 Press and release the same transmitter s RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m for a longer time till LED red diode device and then release it. LED red diode push-buton. LED red diode switches on RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m switches on (constant signal). switches on (first signal pulsates, (signal pulsates) and then switches off - RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m Next release PROG push-button. next the signal is constant). THE TRANSMITTER IS ADDED. RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m * - 1-channel transmitters do not cooperate with roller blind controllers. An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE transmitters CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100% , is analogous. CAUTION: Every transmitter can cooperate with ROP-02 in a different mode, depending on how they were added to glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. also a negative influence on the range. VER. 003 20.05.2011

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON Electronics
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted