X-On Electronics has gained recognition as a prominent supplier of ADIS16488BMLZ IMUs - Inertial Measurement Units across the USA, India, Europe, Australia, and various other global locations. ADIS16488BMLZ IMUs - Inertial Measurement Units are a product manufactured by Analog Devices. We provide cost-effective solutions for IMUs - Inertial Measurement Units, ensuring timely deliveries around the world.

ADIS16488BMLZ Analog Devices

ADIS16488BMLZ electronic component of Analog Devices
Images are for reference only
See Product Specifications
Part No.ADIS16488BMLZ
Manufacturer: Analog Devices
Category: IMUs - Inertial Measurement Units
Description: Analog Devices IMUs - Inertial Measurement Units Sensor, Inertial Minus 40C - 105C
Datasheet: ADIS16488BMLZ Datasheet (PDF)
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 3191.7858 ea
Line Total: USD 3191.79

Availability - 0
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0
Ship by Thu. 08 Aug to Mon. 12 Aug
MOQ : 1
Multiples : 1
1 : USD 3191.7858

   
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Sensing Axis
Sensitivity
Acceleration
Output Type
Supply Voltage - Max
Supply Voltage - Min
Maximum Operating Temperature
Minimum Operating Temperature
Bandwidth
Features
Packaging
Range
Resolution
Series
Brand
Interface Type
Sensor Type
Cnhts
Hts Code
Mxhts
Product Type
Factory Pack Quantity :
Subcategory
Taric
Tradename
LoadingGif
 
Notes:- Show Stocked Products With Similar Attributes.

We are delighted to provide the ADIS16488BMLZ from our IMUs - Inertial Measurement Units category, at competitive rates not only in the United States, Australia, and India, but also across Europe and beyond. A long established and extensive electronic component distribution network has enhanced our global reach and dependability, ensuring cost savings through prompt deliveries worldwide. Client satisfaction is at the heart of our business, where every component counts and every customer matters. Our technical service team is ready to assist you. From product selection to after-sales support, we strive to deliver a seamless and satisfying experience. Are you ready to experience the best in electronic component distribution? Contact X-ON Electronics today and discover why X-On are a preferred choice for the ADIS16488BMLZ and other electronic components in the IMUs - Inertial Measurement Units category and beyond.

Image Part-Description
Stock Image 102781-HMC272AMS8
- HMC272AMS8E Mixer 1.7GHz ~ 3GHz Evaluation Board
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 104991-HMC327MS8G
Analog Devices Hittite RF Development Tools Eval PCB
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 105706-HMC384LP4
Analog Devices Hittite Clock & Timer Development Tools Eval PCB
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 105706-HMC506LP4
Analog Devices Hittite Clock & Timer Development Tools Eval PCB
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 107384-HMC493LP3
RF Development Tools HMC493LP3 Evaluation PCB
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 107755-HMC454ST89
Sub-GHz Development Tools HMC454ST89 Evaluation PCB, 900 MHz
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 108190-HMC591LP5
RF Development Tools HMC591LP5 Evaluation PCB
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 106137-HMC370LP4
Analog Devices Hittite RF Development Tools Eval PCB
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 106137-HMC443LP4
RF Development Tools HMC443LP4 Evaluation PCB
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 109266-HMC550A
RF Development Tools HMC550A EVALUATION PCB ASSEMBLY
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Image Part-Description
Stock Image SCC2130-D08-05
IMUs - Inertial Measurement Units GYROSCOPE X-AXIS +/-6G
Stock : 131
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image MTi-670
IMUs - Inertial Measurement Units GNSS/INS Support Module
Stock : 11
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image IMU383ZA-400
IMUs - Inertial Measurement Units Small robust IMU 6DOF. UARTSPI Interface. 1.3 deghour Bias Instability
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image MTI-G-710-2A8G4
IMUs - Inertial Measurement Units GNSSINS
Stock : 2
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image MTI-300-2A8G4
IMUs - Inertial Measurement Units AHRS
Stock : 6
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image MTI-200-2A8G4
IMUs - Inertial Measurement Units VRU
Stock : 5
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image MTI-100-2A8G4
IMUs - Inertial Measurement Units IMU
Stock : 9
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image MTI-680G
IMUs - Inertial Measurement Units Industrial Motion Tracker Sensor Module with GNSSINS and RTK Technology
Stock : 10
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image MTI-670G
IMUs - Inertial Measurement Units Rugged IP68 GNSS/INS 10g, 2000deg/s GNSS Module
Stock : 3
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image 3DM-GX5-GNSS/INS
IMUs - Inertial Measurement Units High Performance GNSS Navigation Sensor, General Package
Stock : 3
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.

Tactical Grade, Ten Degrees of Freedom Inertial Sensor Silicon Anomaly ADIS16488A This anomaly list describes the known bugs, anomalies, and workarounds for the ADIS16488A. Analog Devices, Inc., is committed, through future silicon revisions, to continuously improve silicon functionality. Analog Devices tries to ensure that these future silicon revisions remain compatible with your present software/systems by implementing the recommended workarounds outlined within this document. PERFORMANCE ISSUES Table 1. Error in Soft Iron Correction Factors er001 Background The signal chain for the tri-axis magnetometer in the ADIS16488A includes a user-configurable, 3 3 soft iron correction matrix. Users configure each value in the soft iron correction matrix by writing to its corresponding register. For example, 15 the SOFT IRON S12 register contains the value for correction factor S12. In these registers, 1 LSB = 100/2 . 15 Issue On units that have firmware Revision 1.07 (or earlier), 1 LSB = 12.5/2 , which is eight times lower than the correct value, on the following registers: SOFT IRON S12, SOFT IRON S13, SOFT IRON S21, SOFT IRON S31, and SOFT IRON S32. Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0108, clear all soft iron correction values (write 0x0000 to each SOFT IRON Sxy register) and perform the soft iron correction outside of the ADIS16488A. Related Issues None. Table 2. User Offset Addition Error er002 Background The ADIS16488A provides user-configurable bias correction values for each gyroscope and accelerometer(x, y, and z), through the following registers: XG BIAS HIGH, XG BIAS LOW, YG BIAS HIGH, YG BIAS LOW, ZG BIAS HIGH, ZG BIAS LOW, XA BIAS HIGH, XA BIAS LOW, YA BIAS HIGH, YA BIAS LOW, ZA BIAS HIGH, and ZA BIAS LOW. On units that have firmware Revision 1.07 (or earlier), there is a computation error that results in a small error in the bias of Issue each sensor (for example, less than 0.02/sec for the gyroscopes). Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0108, write 0x0000 to XG BIAS HIGH, XG BIAS LOW, YG BIAS HIGH, YG BIAS LOW, ZG BIAS HIGH, ZG BIAS LOW, XA BIAS HIGH, XA BIAS LOW, YA BIAS HIGH, YA BIAS LOW, ZA BIAS HIGH, and ZA BIAS LOW. Apply the bias correction factors to the gyroscope and accelerometer signals outside of the ADIS16488A. Related Issues None. Table 3. Temperature Compensation Error er003 Background The ADIS16488A leverages internal temperature sensors as control inputs for the compensation of gyroscope and accelerometer measurements. Issue On units that have firmware Revision 1.08 (or earlier), one of the three temperature sensors can be corrupted when using an external clock to drive the sampling. The external clock causes elevated levels of sensitivity to variation in temperature. Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0109, use the internal sample clock if the best temperature sensitivity is necessary. Related Issues None. Table 4. Real-Time Clock (RTC) Functional Issues er004 Background The ADIS16488A provides a RTC function that keeps track of time (seconds, minutes, hours, days, months, and years) while the main processor function is not operating (sleep, powered off ). Issue On units that have firmware Revision 1.08 (or earlier), the days information in TIME DH OUT can experience an overflow condition when the device recovers from sleep mode. Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0109, do not use sleep mode if the RTC Workaround function is critical for the application. Related Issues None. Rev. 0 Document Feedback Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. rights of third parties that may result from its use. Specifications subject to change without notice. No Tel: 781.329.4700 2017 Analog Devices, Inc. All rights reserved. license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. Technical Support www.analog.com ADIS16488A Silicon Anomaly Table 5. Erroneous Barometer Self Test Result in DIAG STS er005 Background The DIAG STS register provides an error flag for the self test function in Bit 11. Issue On units that have firmware Revision 1.08 (or earlier), Register DIAG STS, Bit 11 may remain in a low state, even if the barometer is failing its self test routine. Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0109, do not use Register DIAG STS, Bit 11 to determine the health of the barometer for mission critical functions. Related Issues None. Table 6. Barometer New Data Bit Continues Updating After Failure er006 Background Register SYS E FLAG, Bit 9 indicates that there is new barometer data in the BAROM OUT register when it is in a high state. Issue On units that have firmware Revision 1.08 (or earlier), Register SYS E FLAG, Bit 9 still indicates that new data is available, even if the barometer has experienced a failure. Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0109, do not use Register SYS E FLAG, Bit 9 to determine the operational state of the barometer function. Related Issues None. Table 7. Sleep Mode Recovery Causes Barometer Failure er007 Background The ADIS16488A provides a sleep mode that has a faster recovery time than a complete restart (power-on or reset recovery). Issue On units that have firmware Revision 1.08 (or earlier), recovery from sleep mode can cause failure in the barometer function. Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0109, do not use sleep mode if the barometer is important for the application. Related Issues None. Table 8. Writing to Register FNCTIO CTRL Causes Barometer Failure er008 Background The FNCTIO CTRL register provides a number of user configurations for the input/output lines (DIO1, DIO2, DIO3, and DIO4). Issue On units that have firmware Revision 1.08 (or earlier), writing to the FNCTIO CTRL register can cause the barometer measurement function to lock up. Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0109 and the barometer function is important for the application, reset the operation after writing to Register FNCTIO CTRL and after backing up those settings in the flash. Related Issues None Table 9. Writing to Register GLOB CMD, Bit 1 Causes Barometer Failure er009 Background The Register GLOB CMD, Bit 1 provides a trigger bit for running the self test function on all of the sensors inside of the ADIS16488A. On units that have firmware Revision 1.08 (or earlier), running the self test routine by setting Register GLOB CMD, Bit 1 equal to 1 Issue can cause the barometer measurement function to lock up. Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0109 and the barometer function is important for the application, reset the operation after running the self test function. Related Issues None Table 10. Daylight Savings Time Error in Real-Time Clock er010 Background The ADIS16488A provides a RTC function that keeps track of time (seconds, minutes, hours, days, months, and years) while the main processor function is not operating (sleep, powered off ). Register CONFIG, Bit 1 provides a control for managing against daylight savings time. Issue On units that have firmware Revision 1.08 (or earlier), turning daylight savings time on by setting Register CONFIG, Bit 1 equal to 1 causes a malfunction in the tracking of the RTC. Workaround Read FIRM REV to determine the firmware revision of a unit. If FIRM REV < 0x0109, do not use the daylight savings time setting of Register CONFIG, Bit 1 equal to 1. Related Issues None Rev. 0 Page 2 of 3

Tariff Desc

8543.70.00 - Other machines and apparatus Free
13 No Signal processors (graphic equalisers, crossovers etc.)
91 .. Other

9027.10.00 Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes.

9031.80.00 - MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free
ANALOG DEVICES
Analog Devices Hittite
ANALOG DEVICES (LINEAR TECHNOLOGY)
ANALOG DEVICES (MAXIM INTEGRATED)
ANALOG DEVICES (TRINAMIC)
Analog Devices / Hittite
Analog Devices / Linear Technology
Analog Devices Inc
Analog Devices Inc.
Analog Devices Inc./Maxim Integrated
Analog Devices, Inc.
DA4
Dallas
DALLAS / MAXIM
Dallas Semiconductor (VA)
HANSCHIP semiconductor
LINEAR
LINEAR TECH
Linear Technology
Linear Technology (part of ADI)
LT
LT4
MAXIM
Maxim Integrated
MAXIM INTEGRATED / ANALOG DEVICES
Maxim Integrated Products
MAXIM-DALLAS
MX4
Technology
Trinamic
TRINAMIC / ANALOG DEVICES
Trinamic Motion Control
Trinamic Motion Control GmbH

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON Electronics
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted