POWER Modular High Power System Data Sheet Up to 24000 Watts Total Power: Up to 24 KW Input Voltage: 180-264 Vac 342-528 Vac Single Phase or 3-Phase of Outputs: Up to 8 SPECIAL FEATURES iHP12 iHP24 5 years manufacturers warranty Multi output intelligent and modular high power system Color: 100% Blue, 50% Magenta, Font: Minion Bold for VS iHP24 Electrical Specifications 0% Yellow, 0% Black Minion italic for i size for each is the sameV - 100% Black Created on Mac Standard 19 rack Input Parameter 19 Rack 24 KW strapped as 19 Rack 24 KW strapped as Outputs parallel up to 1600 A 3-phase 380/480 Vac Nominal 3-phase 208/240 Vac Nominal Outputs series up to 1000 V (iHP24H3A/L) (iHP24L3A/L) 100% digital control Input range 342 Vac to 528 Vac 187.5 Vac to 264 Vac Outputs program as voltage or current (Nominal rating 380/480 Vac) (Nominal rating 208/240 Vac) source Number of phases 3-phase (Wye or Delta) 4 wire total (3-phase and 1 protective earth ground) Versatile input configurable to: Frequency 47-63 Hz Low line 180-264 Vac single phase and 3-phase Phase detection Loss of phase will inhibit unit off. High line 342-528 Vac 3-phase Housekeeping/comms must continue with phase loss. Medical safety approved NO Max current/phase 51 A 342 Vac 84 A 187.5 Vac ISOLATION XFMR NEEDED 40 A 432 Vac Flexible control interfaces (Note 1) Undervoltage Nominal input locked on at turn-on. Undervoltage shutdown at 15% below nominal. Air cooled detection Turn-on at 12% below nominal. Not to interfere with SEMI F47 specs. Semi F47 compliance Current inrush 2.5 x Max input current Field upgradeable firmware Power factor > 0.98 full load and nominal line Programmable slew rate Harmonic distortion THD < 13%, PWHD < 22% (refer to EN 61000-3-12) Fast current slew rate up to 200 Hz Line interruption Designed to meet SEMI F47-0706, 53, 58, S14 at nominal input voltages Active power factor correction Input leakage current < 2.5 mA (Note for fixed condition 3rd edition leakage = 5 mA) User defined command profiles Power switch Front panel power switch provided Input protection Internal fuse (not user serviceable) SAFETY Input overvoltage nd Up to 115% of nominal input shall not damage unit UL 60950-1 2 Edition EN60950-1 protection IEC60950-1/EN60950 Phase imbalance 5% nd CSA C22.2 No. 60950-1-07, 2 Edition Rack parallel Up to 6 racks (144 KW) EN60601-1 IEC60601-1 IEC60601 Efficiency > 90% 3P 380 Vac full load > 91% 3P 240 Vac full load UL 60601-1 1st Edition ANSI/AAMI > 91% 3P 480 Vac full load > 90% 3P 208 Vac 3P full load rd ES60601-1 (2005 + C1:09 + A2:10) 3 Standby voltage 5 V Ed Standby regulation 4.75 - 5.25 V CAN/CSA-C22.2 No. 60601-1 (2008) Standby max current 1 A CB Certificate and Report Note 1: Analog 0-5 V or 0-10 V separate for voltage or current Digital Ethernet UDP, RS485, CAN or Ethernet TC/IP with PowerPro CE (LVD+RoHS), EN60950-1 Connect Module option. Command protocol is patterned to PMBus specification using a proprietary transaction protocol.iHP Data Sheet iHP12 Electrical Specifications Input Parameter 19 Rack 12 KW strapped as Type: 19 Rack 12 KW strapped as Type: 19 Rack 12 KW strapped 1-phase 200/220/230/240 Vac 3-phase 200/208/240 Vac Nominal as 3-phase 380/480 Vac Nominal Nominal (iHP12L1A) (iHP12L3A) (iHP12H3A) Input range 180 Vac to 264 Vac 180 Vac to 264 Vac 342 Vac to 528 Vac (Nominal rating 200/220/230/240 Vac) (Nominal rating 200/208/240 Vac) (Nominal rating 380/480 Vac) 1-phase 3-wire total (2-phase and 1 Number of phases 3-phase (Wye or Delta) 4-wire total (3-phase and 1 protective earth ground) protective earth ground) Frequency 47-63 Hz Loss of phase will inhibit unit off. Phase detection NA Housekeeping/comms must continue with phase loss. 23 A 342 Vac Max current/phase 75 A 180 Vac 44 A 180 Vac 19 A 432 Vac Nominal input locked on at turn-on. Undervoltage shutdown at 15% below nominal. Turn-on at 12% below nominal. Undervoltage detection Not to interfere with SEMI F47 specs. Current inrush 2.5 x Max input current Power factor > 0.99 full load and nominal line > 0.98 full load and nominal line Harmonic distortion THD < 3.5%, PWHD < 22% (refer to EN 61000-3-12) Line interruption Designed to meet SEMI F47-0706, 53, 58, S14 at nominal input voltages Input leakage current < 1.25 mA <2.5 mA Power switch Front panel power switch provided Input protection Internal fuse (not user serviceable) Input overvoltage protection Up to 115% of nominal input shall not damage unit Phase imbalance NA < 5% < 5% Rack parallel Up to 6 racks (72 KW) > 91% 1P 240 Vac full load > 91% 3P 240 Vac full load > 90% 3P 380 Vac full load Efficiency > 90% 1P 208 Vac/200 Vac full load > 90% 3P 208 Vac/200 Vac full load > 91% 3P 480 Vac full load Standby voltage 5 V Standby regulation 4.75 - 5.25 V Standby max current 1 A EMC/Immunity Parameter All Models (Unless otherwise specified) ESD EN61000-4-2 (IEC1000-4-2) Fast Transients EN61000-4-4 (IEC1000-4-4) Surge Immunity EN61000-4-5 (IEC1000-4-5) Conducted Immunity EN61000-4-6 (IEC1000-4-6) Radiated Immunity EN61000-4-3 (IEC1000-4-3) Power Frequency Magnetic Field EN61000-4-8 Voltage Dips, Short Interruptions and Voltage Variations EN 61000-4-34 Conducted Emission EN55011, FCC CFR 47, Part 15, Subpart B Radiated Emission EN55011, FCC CFR 47, Part 15, Subpart B