POWER Modular High Power System Data Sheet Up to 24000 Watts Total Power: Up to 24 KW Input Voltage: 180-264 Vac 342-528 Vac Single or 3-Phase for iHP12 3-Phase for iHP24 540-660 Vac 3-Phase for iHP24C of Outputs: Up to 8 iHP12 iHP24 SPECIAL FEATURES Color: 100% Blue, 50% Magenta, Font: Minion Bold for VS iHP24 Electrical Specifications 0% Yellow, 0% Black Minion italic for i size for each is the sameV - 100% Black Created on Mac 5 years manufacturers warranty Input 19 Rack 24 KW 19 Rack 24 KW 19 Rack 24 KW Multi output intelligent and modular Parameter strapped as 3-phase strapped as 3-phase strapped as 3-phase high power system 380/480 Vac Nominal 208/240 Vac Nominal 600 Vac Nominal Standard 19 rack (iHP24H3A) (iHP24L3A) (iHP24C3A) Input range 342 Vac to 528 Vac 187.5 Vac to 264 Vac 540 Vac to 660 Vac Outputs parallel up to 1600 A (Nominal rating 380/480 Vac) (Nominal rating 208/240 Vac) (Nominal rating 600 Vac) Outputs series up to 1000 V 3-phase Wye 5 wire total 100% digital control Number of 3-phase (Wye or Delta) 4 wire total (3-phase and 1 (3-phases, neutral and phases protective earth ground) Outputs program as voltage or current protective earth ground) source Frequency 47-63 Hz Versatile input configurable to: Phase detection Loss of phase will inhibit unit off. Low line 180-264 Vac single phase Housekeeping/comms must continue with phase loss. and 3-phase Max current/ 51 A 342 Vac 84 A 187.5 Vac 29 A 312 Vac High line 342-528 Vac 3-phase phase 40 A 432 Vac High line 540-660 V ac 3-phase Undervoltage Nominal input locked on at turn-on. Undervoltage shutdown at 15% below nominal. (iHP24C) detection Turn-on at 12% below nominal. Not to interfere with SEMI F47 specs. Medical safety approved NO Current inrush 2.5 x Max input current ISOLATION XFMR NEEDED Power factor > 0.98 full load and nominal line Analog Interface either 0-5 V or 0-10 V Harmonic THD < 13%, PWHD < 22% (refer to EN 61000-3-12) for both current and voltage. distortion Compatible with, but not limited to Line interruption Designed to meet SEMI F47-0706, 53, 58, S14 at nominal input voltages Priva, Argus, TrollMaster and Hortimax Input leakage controllers < 2.5 mA (Note for fixed condition 3rd edition leakage = 5 mA) current Flexible digital control interfaces (Note 1) Power switch Front panel power switch provided Air cooled Input protection Internal fuse (not user serviceable) Semi F47 compliance Input overvoltage Up to 115% of nominal input shall not damage unit protection Field upgradeable firmware Phase imbalance 5% Programmable slew rate Rack parallel Up to 6 racks (144 KW) Fast current slew rate up to 200 Hz > 91% 3P 240 Vac full load Efficiency > 90% 3P 380 Vac full load Active power factor correction > 90% 3P 208 Vac 3P full > 90% 3P 600 Vac full load > 91% 3P 480 Vac full load User defined command profiles load Standby voltage 5 V Standby SAFETY 4.75 - 5.25 V regulation nd UL 60950-1 2 Edition EN60950-1 Standby max IEC60950-1/EN60950 1 A current nd CSA C22.2 No. 60950-1-07, 2 Edition Note 1: Digital Ethernet UDP, RS485, CAN or Ethernet TC/IP with PowerPro Connect Module option. Command protocol is patterned to EN60601-1 IEC60601-1 IEC60601 PMBus specification using a proprietary transaction protocol. UL 60601-1 1st Edition ANSI/AAMI rd ES60601-1 (2005 + C1:09 + A2:10) 3 Ed CAN/CSA-C22.2 No. 60601-1 (2008) CB Certificate and Report CE (LVD+RoHS), EN60950-1iHP Data Sheet SafetyTable Model Number Model Code Module Nominal Voltage Safety Compliance Maximum Total Voltage Allowed 73-936-0012 SL Medical 2MOPP* 300 V 48 V 73-936-0024 SQ Medical2MOOP**,ITE 400 V 73-936-0048 SW 73-936-0080 S8 Medical 2MOPP 600 V 80 V 73-936-0125 S1 Medical 2MOOP 800 V 73-936-0200 SA Medical 2MOOP 800 V 73-936-0250 S2 ITE 1000 V Note: * -2MOPP or 2 MOPP (Means of Patient Protection) ** -2MOOP or 2 MOOP (Means of Operator Protection) iHP12 Electrical Specifications 19 Rack 12 KW strapped as Type: 19 Rack 12 KW strapped as Type: 19 Rack 12 KW strapped Input Parameter 1-phase 200/220/230/240 Vac 3-phase 200/208/240 Vac Nominal as 3-phase 380/480 Vac Nominal Nominal (iHP12L1A) (iHP12L3A) (iHP12H3A) Input range 180 Vac to 264 Vac 180 Vac to 264 Vac 342 Vac to 528 Vac (Nominal rating 200/220/230/240 Vac) (Nominal rating 200/208/240 Vac) (Nominal rating 380/480 Vac) 1-phase 3-wire total (2-phase and 1 Number of phases 3-phase (Wye or Delta) 4-wire total (3-phase and 1 protective earth ground) protective earth ground) Frequency 47-63 Hz Loss of phase will inhibit unit off. Phase detection NA Housekeeping/comms must continue with phase loss. 23 A 342 Vac Max current/phase 75 A 180 Vac 44 A 180 Vac 19 A 432 Vac Nominal input locked on at turn-on. Undervoltage shutdown at 15% below nominal. Turn-on at 12% below nominal. Undervoltage detection Not to interfere with SEMI F47 specs. Current inrush 2.5 x Max input current Power factor > 0.99 full load and nominal line > 0.98 full load and nominal line Harmonic distortion THD < 3.5%, PWHD < 22% (refer to EN 61000-3-12) Line interruption Designed to meet SEMI F47-0706, 53, 58, S14 at nominal input voltages Input leakage current < 1.25 mA <2.5 mA Power switch Front panel power switch provided Input protection Internal fuse (not user serviceable) Input overvoltage protection Up to 115% of nominal input shall not damage unit Phase imbalance NA < 5% < 5% Rack parallel Up to 6 racks (72 KW) > 91% 1P 240 Vac full load > 91% 3P 240 Vac full load > 90% 3P 380 Vac full load Efficiency > 90% 1P 208 Vac/200 Vac full load > 90% 3P 208 Vac/200 Vac full load > 91% 3P 480 Vac full load Standby voltage 5 V Standby regulation 4.75 - 5.25 V Standby max current 1 A EMC/Immunity Parameter All Models (Unless otherwise specified) ESD EN61000-4-2 (IEC1000-4-2) Fast Transients EN61000-4-4 (IEC1000-4-4) Surge Immunity EN61000-4-5 (IEC1000-4-5) Conducted Immunity EN61000-4-6 (IEC1000-4-6) Radiated Immunity EN61000-4-3 (IEC1000-4-3) Power Frequency Magnetic Field EN61000-4-8 Voltage Dips, Short Interruptions and Voltage Variations EN 61000-4-34 Conducted Emission EN55011, FCC CFR 47, Part 15, Subpart B Radiated Emission EN55011, FCC CFR 47, Part 15, Subpart B