Embedded Power for Business-Critical Continuity Rev. 05.23.07 AIF Series 1 of 2 AIF Series RoHS 600 Watts Total Power: 600 Watts (12V 50Amps) Input Voltage: 300V of Outputs: Single Electrical Specifications Input Input ra nge 250 - 420 VDC Input surge 450V / 100ms Special Features Efficiency 90% 5.0V (Typical) 600W Continuous power at Output 100C baseplate temperature 3 3 108W/in (6.6W/cm ) Load Regulation 0.2% typical down to no load High efficiency - up to 90% Line Regulation 0.2% typical Low output ripple and noise Noise / Ripple 100mV typical (below 5V) 2% typical (5V and above) Positive and Negative enable Up to 0.5V Remote sense function +/-20% for 5V and above +10%/ -50% for below 5V Output voltage adjust range Excellent transient response 5% max for 3.3V and above, 150mV for 1.8V, deviation with 25% Transient Response OVP, OCP, V Adj control with to 75% full load 250 S (max) recovery TM ALP analog mode linear 2 control, or through I C bus Current Share Accuracy 3% typical with digital mode control. Overvoltage Protection 115% Vo (nominal) Paralleable with accurate Current Limit 115% Io maximum current sharing Control EU Directive 2002/95/EC Voltage Adjust 80 to 120% Vo linear programming for 12V, 15V, 24V, 48V 50% compliant for RoHS to 110% for 1.8V - 5.0V Enable TTL compatible (positive & negative enable options) Current Limit Adjust 20 to 100% Io linear programming or digital mode control Clock Input (external sync) 3.3 to 5.5Vp-p 800KHz 10% Clock Output (internal clock) 4.5Vp-p typical 800KHz 5% Power Good Identification High (Vo) = power good Temperature Monitor Output 10mV/K (2.73 = 0C) Current Monitor Output 0 to 1mA (1mA = 100% I ) o rated Over Voltage Protection 110 to 150% Vo linear programming by voltage or resistor, Adjust or digital mode control Safety Notes Nominal values apply with sense pins connected and other control pin unconnected. UL 60950 Recognized ALP: Astec Linear Programming cUL 60950 Recognized TUV EN60950 Licensed CE CE MarkEmbedded Power for Business-Critical Continuity Rev. 05.23.07 AIF Series 2 of 2 Americas Environmental Specifications 5810 Van Allen Way Carlsbad, CA 92008 Operating temperature -20C to +100C (case temperature) USA Start up temperature -40C to +100C (case temperature) Telephone: +1 760 930 4600 Storage temperature -40C to +125C Facsimile: +1 760 930 0698 Overtemperature protection 110C max Europe (UK) Waterfront Business Park Ordering Information Pin Assignments Merry Hill, Dudley Input Voltage Output Voltage Efficiency Model Number Input (AC) Output (DC) Control Pins West Midlands, DY5 1LX 300V 1.8V 120A 80% (Typ) AIF120Y300 31. Positive 21. Positive 1. +Sense United Kingdom 32. Negative 22. Positive 2. Temp Mon 300V 3.3V 120A 87% (Typ) AIF120F300 Telephone: +44 (0) 1384 842 211 23. Positive 3. C Mon 300V 5.0V 80A 90% (Typ) AIF80A300 Facsimile: +44 (0) 1384 843 355 24. Positive 4. C Share 300V 12V 50A 90% (Typ) AIF50B300 25. Negative 5. Clk Out 300V 15V 40A 90% (Typ) AIF40C300 26. Negative 6. Clk In Asia (HK) 300V 24V 25A 90% (Typ) AIF25H300 27. Negative 7. PG/ID 16th - 17th Floors, Lu Plaza 1. For Negative enable, add suffix -N. 28. Negative 8. C Lim Adj 2 Wing Yip Street, Kwun Tong 2. For Non-thread hole, add suffix -NT. 9. OVP Adj Kowloon, Hong Kong 3. For RoHS 6, add suffix -L. Default is RoHS 5. 10. V Adj Telephone: +852 2176 3333 11. Enable Facsimile: +852 2176 3888 12. -Sense Mechanical Drawing For global contact, visit: www.astecpower.com www.artesyn.com technicalsupport astec.com technicalsupport artesyn.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and dis- claims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2005 Emerson Electric Co.