process yellow 116 1375 1797 375 3405 313 2985 240 Embedded Power for Business-Critical Continuity 242 2607 Rev.03.22.07 exb30s 1 of 4 652 EXB30 Series Single output Total Power: 16-30W Input Voltage: 36-75VDC of Outputs: Single The EXB30 is a new high efficiency open frame isolated 30 Watt Special Features High efficiency topology, converter series in an industry standard footprint. The first five 92% typical at 5 V models in the series feature a 2:1 input voltage range of 36 Vdc Industry standard footprint Wide operating temperature, to 75 Vdc and are available in output voltages of 12 V, 5 V, 3.3 V, -40 C to +85 C 2.5 V and 2 V. Each model is trimmable from 80% to 110% except (natural convection) 80% to 110% output trim the 12 V output which has a wider trim range of 60% to 110%. No minimum load Overvoltage and The sub 5 V models have an output current rating of 8 A. Typical overtemperature protection efficiencies for the models are 92% for the 5 V, 90% for the 3.3 V Remote sense compensation Remote ON/OFF and 12V, 87% for the 2.5 V and 86% for the 2 V version. The EXB30 Available RoHS compliant series offers remote ON/OFF and remote sense compensation to 2 year warranty correct for voltage drops at the load. Overcurrent, overvoltage and overtemperature protection features are included as standard. With full international safety approval including EN60950 and cUL1950, the EXB30 reduces compliance costs and time to market.process yellow 116 1375 1797 375 3405 313 2985 240 242 Embedded Power for Business-Critical Continuity 2607 Rev.03.22.07 exb30s Specifications 2 of 4 652 All specifications are typical at nominal input, full load at 25 C unless otherwise stated. OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Voltage adjustability 80% to 110% Conducted emissions EN55022 (See Note 3) Level A EN55022 (See Note 3) Level B Set point accuracy 1.5% max. Radiated emissions EN55022 (See App. Note 108) Level B Immunity: Line regulation Low line to high line 0.1% max. ESD air EN61000-4-2 8 kV (NP), 15 kV (RP) ESD contact EN61000-4-2 6 kV (NP), 8 kV (RP) Load regulation Full load to min. load 0.2% max. Radiated field enclosure EN61000-4-3 10 V/m (NP) Total error band 3.0% Conducted (DC power) EN61000-4-6 10 V (NP) Conducted (signal) EN61000-4-6 10 V (NP) Minimum load 0% Input transients ETS 300 132-2, ETR 283 Overshoot At turn-on and turn-off None GENERAL SPECIFICATIONS Undershoot None Efficiency See table Ripple and noise 5 Hz to 20 MHz 150 mV pk-pk Basic insulation Input/output 1500 Vdc (See Note 1) 20 mV rms Switching frequency Fixed 300 kHz typ. Temperature coefficient 0.02%/C Approvals and VDE0805, EN60950 Transient response 2.0% max. deviation standards IEC950, UL/cUL1950 (See Note 2) 300 s recovery to (See Note 5) CSA C22.2 No. 950 within total error band Material flammability UL94V-0 Remote sense 10% output voltage change Weight 40 g (1.41 oz) INPUT SPECIFICATIONS MTBF MIL-HDBK-217F >300,000 hours 25 C, 100% load Input voltage range 48 Vin nominal 36-75 Vdc ground benign Input current No load 50 mA max. ENVIRONMENTAL SPECIFICATIONS Remote OFF 10 mA max. Input current (max.) 48 V models 1.0 A max. Io max. Thermal performance Operating ambient -40 C to +85 C (See Note 4) and Vin = 36-75 Vdc temperature Non-operating -40 C to +125 C Input reflected ripple (See Note 6) 30 mA (pk-pk) typ. ETS 300 019-2-3 Classes T3.1 to T3.5 Active high remote ON/OFF Logic compatibility Open collector ref to -input Altitude Operating 10,000 feet max. ON Open circuit or >2 Vdc Non-operating 40,000 feet max. OFF <1.2 Vdc Undervoltage lockout 48 Vin: power up 34 V 48 Vin: power down 31.5 V Start-up time Power up 30 ms (See Note 7) Remote ON/OFF 30 ms