POWER MP Series Data Sheet 400 - 1200 Watts Total Power: 400 - 1200 W Input Voltage: 85 - 264 VAC of Outputs: Up to 21 Special featureS Current share on all outputs with ratings of 10 A or greater Remote sense on all outputs with ratings greater than 2 A Overload protection on all outputs Electrical Specifications Voltage adjustment on all outputs Input Margining on all single output modules Input ra nge 85 - 264 Vac Input OK signal and status indicator LED Global DC OK signal and status indicator LED Frequency 47 - 440 Hz Global and individual module inhibits/enable Inrush current 40 A peak max. (soft start) Two year warranty Efficiency 70 - 80% typ. full case load Forced air cooling, field replaceable fan Isolated 5 V bias voltage Power factor 0.99 typ. meets EN61000-3-2 Power factor correction Turn-on time AC on 1.5 sec typ. EN61000-3-2 harmonic distortion compliance Inhibit/enable 150 ms typ. CISPR 22, EN55022 Curve B conducted/ EMI filter standard CISPR 22/EN55022 Level B radiated EMI EMI filter (low leakage option) CISPR 22/EN55022 Level A European CE Mark requirements Leakage current standard 2.0 mA max. 240 Vac Optional VME timing and system DC OK module Leakage current (low leakage option) 300 A max. 240 Vac Customer-provided air option Radiated EMI CISPR 22/EN55022 Level B Additional 200 W output high line (180-264 Vac) Holdover storage 20 ms minimum (independent of input Vac) Low leakage option for medical applications AC OK > 5 ms early warning min. before outputs lose regulation EN61000 immunity standards Full cycle ride thru (50 Hz) Standard modification flexibility Harmonic distortion Meets EN61000-3-2 (consult factory) Isolation Meets EN60950 Low noise fan Fan fail signal Efficiency 70 - 80% typ. full case load Module enable Outputs down to 0.5V Global Inhibit/Enable TTL, Logic 1 and Logic 0 Field demonstrated MTBF: > 550,000 hours Input fuse (internal) MP4: 10 A MP6: 15 A MP8: 20 A MP1: 20 A at full load, 220 Vac & 25 C ambient Warranty 2 years conditions SafetY UL UL1950 CSA CSA22.2 No. 234 Level 5 IEC IEC950, Class 1 VDE EN60950 BABT Compliance to EN 60950, BS 7002 CB Certificate and report CE MarkMP Series Data Sheet Electrical Specifications Output Output (cont.) Adjustment range 10% minimum all outputs All outputs disabled when internal temp exceeds Thermal protection safe operating range. > 5 ms warning (AC OK 1 Margining 4 - 6% nominal signal) before shutdown Overall regulation 0.4% or 20mV max. Up to 0.5 V total drop (not avbl on triple output (36 W modules 4% maximum) Remote sense module) RMS: 0.1% or 10 mV, whichever is greater 2 Single wire parallel Current share to within 2% of total rated current Ripple Pk-Pk: 1.0% or 50 mV, whichever is greater 2 Bandwidth limited to 20 MHz DC OK -2% to -8% of nominal for any monitored output Dynamic response < 2% or 100 mV, with 25% load step Minimum load Not required on single or triple output. 10% 3 required on main of dual output Recovery time To within 1% in < 300 sec Housekeeping bias voltage 5 Vdc 1.0 A max. present whenever AC input Overcurrent protection** Single output module & main output of dual is applied output module Module inhibit TTL, isolated, singles and dual (both outputs) 105-120% of rated output current. only Aux output of dual output module 105 -140% Switching frequency 250k Hz of rated output current Output/Output isolation > 1 Megohm Shortcircuit protection Protected for continuous short-circuit VME signal option board POR signal & quad external DC OK Recovery auto upon removal of short 1-slot module providing additional 34 mSec Overvoltage protection Single output module: 2 - 5.5 V 122 - 134% Hold-up module (HUP) (60 mSec total) hold-up 600 W loading. (measured at sense 6 - 60 V 110 - 120% connection) > 550,000 hours at full load, 220 Vac and Dual output module: 2 - 6 V 122 - 134% Field Demonstrated MTBF 25 C ambient conditions 8 - 28 V 110 - 120% 1. Single output modules only. Triple output module: No overvoltage protection provided. Recycle AC input voltage 2. Single and main of dual output modules only to reset OVP circuit 3. Contact factory for optional preload if required Reverse voltage protection 100% of rated output current Environmental Specifications Operating temperature -20 C to 70 C for standard airflow, -20 C to 40 C for reverse airflow (cold start 0 C) Derate each output from 100% down to 50% load from 50 C to 70 C for forward airflow Shock/Vibration Mil-Hdbk 810E Humidity 95% non-condensing Storage temperature -40 C to 85 C Temperature co-efficient 0.02% per C Cooling Internal DC fan or customer provided air (option) Output Module Line-up Module Type Single Single Single Dual Triple Output 1 1 2 3 Max output power 210 W 360 W 600 W 144 W 36 W Max output current 35 A 60 A 120 A 10 A 2 A Volts 2 - 60 V 2 - 60 V 2 - 60 V 2 - 28 V 2 - 28 V Standard voltage increments 25 25 25 19 18 Remote sense on outputs Yes Yes Yes Yes, both No Remote margin/V-Program Yes Yes Yes No No Module Inhibit (isolated) Yes Yes Yes Single wire active current share Yes Yes Yes Yes, main only Overvoltage/overcurrent protection Yes Yes Yes Yes Over current Minimum load required No No No Yes (10%) main only No Slots occupied in any MP case 1 2 3 1 1 Internal Part Number Reference Table Part Where X = Description Module Code 73-690-0001 N/A MP1 Case MP1