POWER MP Series Data Sheet 400 - 1200 Watts Total Power: 400 - 1200 W Input Voltage: 85 - 264 VAC 120 - 350 VDC of Outputs: Up to 21 Special ef aut re S Current share on all outputs with ratings of 10 A or greater Remote sense on all outputs with ratings greater than 2 A Electrical Specicfi ations Overload protection on all outputs Voltage adjustment on all outputs Input Margining on all single output modules Input range: 85 - 264 Vac Input OK signal and status indicator LED 120 - 350 Vdc Global DC OK signal and status indicator LED Frequency: 47 - 440 Hz Global and individual module inhibits/enable Inrush current: 40 A peak max. (soft start) 2 year warranty Forced air cooling, efi ld replaceable fan Efficiency: 70 - 80% typ. full case load Isolated 5 V bias voltage Power factor: 0.99 typ. meets EN61000-3-2 Power factor correction AC on 1.5 sec typ. Turn-on time: EN61000-3-2 harmonic distortion compliance inhibit/enable 150 ms typ. CISPR 22, EN55022 Curve B conducted/ EMI filter standard: CISPR 22/EN55022 Level B radiated EMI EMI filter (low leakage option): CISPR 22/EN55022 Level A European CE Mark requirements Optional VME timing and system DC OK Leakage current standard: 2.0 mA max. 240 Vac module Leakage current (low leakage option): 300A max. 240 Vac Customer-provided air option Radiated EMI: CISPR 22/EN55022 Level B Additional 200 W output high line (180-264 VAC) Holdover storage: 20 ms minimum (independent of input Vac) Low leakage option for medical applications AC OK: > 5 ms early warning min. before outputs lose regulation EN61000 immunity standards Full cycle ride thru (50 Hz) Standard modicfi ation efl xibility Harmonic distortion: Meets EN61000-3-2 (consult factory) Low noise fan Isolation: Meets EN60950 Fan fail signal Efficiency: 70 - 80% typ. full case load Module enable Outputs down to 0.5V Global Inhibit/Enable: TTL, Logic 1 and Logic 0 Field Demonstrated MTBF: > 550,000 hours Input fuse (internal): MP4: 10 A MP6: 15 A MP8: 20 A MP1: 20 A at full load, 220 Vac & 25 C ambient Warranty: 2 years conditions Saef t Y UL UL1950 CSA CSA22.2 No. 234 Level 5 IEC IEC950, Class 1 VDE EN60950 BABT Compliance to EN 60950, BS 7002 CB Certicfi ate and report CE MarkMP Series Data Sheet Electrical Specicfi ations Electrical Specicfi ations Electrical Specicfi ations Output Output (cont.) Adjustment range: 10% minimum all outputs All outputs disabled when internal temp exceeds Thermal protection: safe operating range. > 5 ms warning (AC OK 1 Margining: 4 - 6% nominal signal) before shutdown Overall regulation: 0.4% or 20mV max. Up to 0.5 V total drop (not avbl on triple output (36 W modules 4% maximum) Remote sense: module) RMS: 0.1% or 10 mV, whichever is greater 2 Single wire parallel: Current share to within 2% of total rated current Ripple: Pk-Pk: 1.0% or 50 mV, whichever is greater 2 Bandwidth limited to 20 MHz DC OK: -2% to -8% of nominal for any monitored output Dynamic response: < 2% or 100 mV, with 25% load step Minimum load: Not required on single or triple output. 10% 3 required on main of dual output Recovery time: To within 1% in < 300 sec Housekeeping bias 5 Vdc 1.0 A max. present whenever AC input Overcurrent protection:** Single output module & main output of dual voltage: is applied output module Module inhibit: TTL, isolated, singles and dual (both outputs) 105-120% of rated output current. only Aux output of dual output module 105 -140% Switching frequency: 250k Hz of rated output current Output/Output isolation: > 1 Megohm Short-circuit protection: Protected for continuous short-circuit VME signal option board: POR signal & quad external DC OK Recovery auto upon removal of short 1-slot module providing additional 34 mSec Overvoltage protection: Single output module: 2 - 5.5 V 122 - 134% Hold-up module (HUP): (60 mSec total) hold-up 600 W loading. (measured at sense 6 - 60 V 100 - 120% connection) > 550,000 hours at full load, 220 Vac and Dual output module: 2 - 6 V 122 - 134% Field Demonstrated MTBF: 25 C ambient conditions 8 - 28 V 110 - 120% 1. Single output modules only. Triple output module: No overvoltage 2. Single and main of dual output modules only protection provided. Recycle AC input voltage to reset OVP circuit 3. Contact factory for optional preload if required Reverse voltage protection: 100% of rated output current Environmental Specicfi ations Operating temperature: -20 C to 50 C (start 0 C) (derate each output linearly to 50% at 70 C) (-20 C to 40 C max. with rear air option) Shock/Vibration: Mil-Hdbk 810E Humidity: 95% non-condensing Storage temperature: -40 C to 85 C Temperature coefficient: 0.02% per C Cooling: Internal DC fan or customer provided air (option) Output Module Line-up Module Type Single Single Single Dual Triple Output: 1 1 2 3 Max output power: 210 W 360 W 600 W 144 W 36 W 120 mV Max output current: 35 A 60 A 120 A 10 A 2 A Volts: 2 - 60 V 2 - 60 V 2 - 60 V 2 - 28 V 2 - 28 V Standard voltage increments: 25 25 25 19 18 Remote sense on outputs: Yes Yes Yes Yes, both No Remote margin/V-Program: Yes Yes Yes No No Module Inhibit (isolated): Yes Yes Yes Single wire active current share: Yes Yes Yes Yes, main only Over voltage/over current protection: Yes Yes Yes Yes Over current Minimum load required: No No No Yes (10%) main only No Slots occupied in any MP case: 1 2 3 1 1