POWER NLP40 Series Data Sheet Single, Dual and Triple Output Total Power: 40 - 50 W Input Voltage: 90 - 264 Vac 120 - 370 Vdc of Outputs: Single, dual, triple SPECIAL FEATURES 4.25 x 2.5 x 1.15 inch package (1U applications) Universal input Overvoltage and short circuit Electrical Specifications protection 40 W with free air convection Input EN55022, EN55011 conducted Input voltage range Universal input 90 - 264 Vac emission level B (See Note 9) 120 - 370 Vdc EN61000-4-2, -3, -4, -5, -6 immunity Input frequency range 47 - 440 Hz compliant Input surge current 120 Vac, cold start 15 A max. UL, VDE and CSA safety approvals 230 Vac, cold start 30 A max. NLP40 enclosure kit available Safety ground leakage current 120 Vac, 60 Hz 0.2 mA RoHS compliant 230 Vac, 50 Hz 0.4 mA Input current 120 Vac 1.4 A rms SAFETY 230 Vac 0.7 A rms VDE0805/EN60950/IEC950 Input fuse UL/IEC127 250 Vac H 3.15 A File 10401-3336-0093 Output Licence No. 93662 UL 60950 File No. E132002 Total regulation Main output 2.0% (Line and load) Auxiliary outputs 5.0% CSA C22.2 No. 950 File No. LR41062C Rise time At turn-on 1.0 s, max. Transient response Main output 5.0% max. dev., 25% step at 0.1 A/s 1 ms rec. to 1.0% Temperature coefficient 0.02%/C Overvoltage protection Main outputs 135%, 15% Short circuit protection Cyclic operation Continuous Minimum output current Single 0 A Multiple (See Note 5)NLP40 Series Data Sheet (10) EMC Charateristics Conducted emissions EN55022, FCC part 15 Level B Radiated emissions EN55022, FCC part 15 Level A ESD air EN61000-4-2, level 3 Perf. criteria 1 ESD contact EN61000-4-2, level 3 Perf. criteria 1 Surge EN61000-4-5, level 3 Perf. criteria 1 Fast transients EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity EN61000-4-3, level 3 Perf. criteria 1 Conducted immunity EN61000-4-6, level 3 Perf. criteria 1 General Specifications Hold-up time 120 Vac 12 ms 40 W 230 Vac 20 ms 40 W Efficiency 75% typical Isolation voltage Input/output 3000 Vac Input/chassis 1500 Vac Switching frequency Fixed 65 kHz, 5 kHz Approvals and standards UL, CSA VDE 60950, IEC950, UL1950 (See Note 8) VDE0805, CSA C22.2 No. 950 Weight 200 g (7.06 oz) MTBF demonstrated MIL-HDBK-217F 150,000 hours min. Environmental Specifications Thermal performance Operating ambient (see derating curve) 0 C to +70 C (See Notes 6, 7, 9) Non-operating -40 C to +70 C 50 C to 70 C ambient, convection cooled Derate to 50% load 0 C to 50 C ambient, convection cooled 40 W 0 C to 50 C ambient, 20 CFM forced air 50 W Peak (0 C to +50 C, 60 s) (See Note 2) Relative humidity Non-condensing 5 to 95% RH Altitude Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 4): 5-500 Hz 2.4 G rms peak Shock Per MIL-STD-810E 516.4 Part IV