Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 7813LC Multi-Conductor - Enhanced Category 6 Bonded-Pair Cable For more Information please call 1-800-Belden1 General Description: CAT6 (250MHz), 4-Bonded-Pairs, U/UTP-Unshielded, Limited Combustible-FHC 25/50, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, FEP Insulation, Central Filler, FEP Jacket Usage (Overall) Suitable Applications: Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155 ATM, 622 ATM, 250MHz Category 6, Enviroments benefitting from Limited Combustible Cable Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material 4 23 Solid BC - Bare Copper Total Number of Conductors: 8 Insulation Insulation Material: Insulation Material FEP - Fluorinated Ethylene Propylene Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Teflon FEP - Fluorinated Ethylene Propylene Outer Jacket Diameter: Nom. Dia. (in.) 0.214 Overall Cable Overall Cabling Separator Material: Central Filler Pair Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +150C Bulk Cable Weight: 28 lbs/1000 ft. Max. Recommended Pulling Tension: 40 lbs. Min. Bend Radius/Minor Axis: 0.500 in. Min. Bend/Installation: 2.100 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP, FHC 25/50 NEC Articles: 800 Page 1 of 3 09-11-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 7813LC Multi-Conductor - Enhanced Category 6 Bonded-Pair Cable CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class E EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Telecommunications Standards: Category 6 - TIA 568.C.2 Other Specification: 6 Applicable Patents: Country Patent US 5734126 Flame Test UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6), UL723 (NFPA 255) C(UL) Flame Test: FT6 CSA Flame Test: FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 2412 Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pF/ft) 15 Maximum Capacitance Unbalance (pF/100 m): 330 Nominal Velocity of Propagation: VP (%) 72 Maximum Delay: Delay (ns/100 m) 537 100MHz Max. Delay Skew: Delay Skew (ns/100 m) 45 Maximum Conductor DC Resistance: DCR 20C (Ohm/100 m) 8.2 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance 20C (%) 5 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB) Min. SRL (dB) 1 2.0 74.3 72.3 72.3 70.3 20.0 na 4 3.8 65.3 63.3 61.5 59.5 23.0 na 8 5.3 60.8 58.8 55.4 53.4 24.5 na 10 6.0 59.3 57.3 53.3 51.3 25.0 na 16 7.6 56.2 54.3 48.7 46.7 25.0 na 20 8.5 54.8 52.8 46.3 44.3 25.0 na 25 9.5 53.3 51.3 43.8 41.8 24.3 na Page 2 of 3 09-11-2017