BLP55 AC-DC Series Data Sheet 55 Watts Features RoHS lead-free solder and lead-solder-exempted products are available Industry-standard 3 x 5 footprint Main output remote sense CE marked to Low Voltage Directive Compliance to EN61000-4-2/-3/-4/-5/-6/-8 Description The BLP55 Series economical and compact construction provides single or three-output ac-dc power conversion to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. The BLP55 is rated for convection, as well as forced-air cooling. Full output power is available with external forced-air cooling. Other features include main-output remote sense and an internal EMI filter. Single Output Model Selection MODEL NOMINAL OUTPUT MIN-MAXIMUM OUTPUT MIN-MAXIMUM OUTPUT PEAK OUTPUT TOTAL RIPPLE & NOISE 1 2 3 4 VOLTAGE (VDC) CURRENT, CONVECTION CURRENT CURRENT REGULATION % %p-p BLP55-1005 5V 0 to 8A 0 to 11A 12A 2 1 BLP55-1012 12V 0 to 3.3A 0 to 4.5A 5A 2 1 BLP55-1024 24V 0 to 1.6A 0 to 2.3A 2.5A 2 1 Triple Output Model Selection MODEL NOMINAL OUTPUT MIN-MAXIMUM OUTPUT MIN-MAXIMUM OUTPUT PEAK OUTPUT TOTAL RIPPLE & NOISE 1 2 3 4 VOLTAGE (VDC) CURRENT, CONVECTION CURRENT CURRENT REGULATION % %p-p +5V 0.4 to 4A 0.5 to 5A 7A 2 1 BLP55-3000 +12V 0.2 to 2A 0.2 to 2.5A 4A 5 1 -12V 0.0 to 0.5A 0.0 to 0.7A 1 5 1 +3.3V 0.5 to 4A 0.5 to 5A 7A 2.5 1 BLP55-3300 +5V 0.0 to 2A 0.0 to 2.5A 4A 2.5 1 +12V 0.0 to 0.5A 0.0 to 0.7A 1A 5 1 1 NOTES: 10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5 x 1.6 cross-sectional area) with power supply mounted on 0.25 standoffs. Recommended airflow direction is from the AC side to the DC side. 2 Peak current duration for less than 30 Sec with a maximum duty cycle of 10%. 3 At 25 C ambient including voltage set point tolerance, line, and load regulation. 4 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, and bypass capacitors of 10 F and 0.1 F. Ordering Information: OPTIONS SUFFIXES TO ADD TO PART NUMBER RoHS lead solder exempt No RoHS character required. RoHS compliant for all 6 substances Add G as the last character of the part number. 103354D Rev AB1, 06-FEB-09 Page 1 of 6 www.power-one.comBLP55 AC-DC Series Data Sheet 55 Watts Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Single-phase continuous input range. 85 100-250 264 VAC Input Voltage - DC Consult factory. Input Frequency AC input. 47 50/60 63 Hz Input Current At 115 VAC input. 1ARMS Inrush Surge Current Internally limited. Vin = 115 VAC, Max Power, 25 C. 18 APK Internally limited. Vin = 230VAC, Max Power, 25 C. 36 APK Input Fuse Internally located AC input line fuse rated at F, 250 V, 3.15 A. Efficiency At Max Power, -3300 60% nominal. 70 % Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Output Power With convection cooling (-3300 25 W). See Model Selection Table 40 Watts With forced-air cooling (-3300 41 W). See Model Selection Table 55 Output DC Adjustability: Adjustability of Vo1 (Vo2/Vo3 are not adjustable). -5%, +10% Of Nom Overshoot 5% Load Transient Vo1, Vo2, or Vo3 deviation due to a 50 to 100% load change 3 % at a rate of 1A/s. Turn-On Time from AC ON Time required for output voltage to reach within regulation after initial application 1.5 Sec of AC input. Turn-On Delay Time required for output voltage to rise from 10% to 90%. 20 ms Hold-Up Time At 40 W, 115 VAC 20 ms Remote Sense Total compensation for cable losses on Vo1. 500 mV (Remote Sense is not available for Vo2 or Vo3) Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Main output. 3.3V: 3.8 4.5 5V: 5.7 6.8 12V: 13.8 16.2 V 24V: 27.6 32.4 48V: 52.8 56.4 Short Circuit Protection Fully-protected against output short circuit. 103354D Rev AB1, 06-FEB-09 Page 2 of 6 www.power-one.com