Bel Power Solutions SFP450 Series is a 450 Watt, power factor corrected (PFC) front-end which provides a 12 VDC output for datacom and other distributed power applications. Its compact size enables mounting in both 1U and 2U height racks. High efficiencies, advanced thermal management techniques, and an internal fan increase reliability over a broad range of operating conditions. Internal ORing diodes facilitate use in hot-swap (plug)*, redundant configurations. Status is provided with front panel LEDs, logic signals and via the I2C management interface bus. The SFP450 Series meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Wide input voltage range (90-264 VAC) with PFC 3 High power density, 9 W / inch 1U or 2U height configurations Active current share with ORing FET IC interface status and monitoring Standby voltage of 3.3 VDC 3 A Overtemperature, overload, and overvoltage protection Status LEDs: AC OK, POWER GOOD, PS FAIL Datacom Distributed Power Systems * Proper hot-swap (plug) operation instruction: Power supply is not intended to be inserted into the system with AC cord already applied. Alternatively, if there is an application where power supply insertion with AC cord is required PS ON must be toggled or AC recycled after insertion into the system to reset the power supply. 2 SFP450 Series MODEL INPUT VOLTAGE OUTPUT VOLTAGE OUTPUT CURRENT STANDBY OUTPUT OUTPUT POWER SFP450-12BG 100 240 VAC 12 VDC 36.6 A 3.3 V/ 3 A 450 W SFP450-S101G* 100 240 VAC 12 VDC 36.6 A 3.3 V/ 3 A 450 W *SFP450-S101G is the preferred version as the over temperature protection is independent of the current. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS AC Input Voltage Single-phase continuous input range. 90 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at full power. At 115 VAC 20 ms Input Current At full-rated load. At 9 0 VAC 6 Arms Inrush Surge Current Excluding Xcap. Vin = 264 VAC, T = 25 C 15 Apk Power Factor Per EN61000-3-2 > 0.95 W/VA PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS With Vin at 110 VAC and 50% to 75% load on V1. 86 % With Vin at 110 VAC and 75% to 100% load on V1. 86 % 1 Efficiency With Vin at 220 VAC and 50% to 75% load on V1. 87 % With Vin at 220 VAC and 75% to 100% load on V1. 89 % Minimum Load Minimum loading required to maintain regulation. 0 A Output Power 450 W Overshoot Output voltage overshoot at turn-on. < 5 % Maximum recovery time to within 1% of initial 12V output: 5 ms set point due to a 25% load change, 1A/s. St andby output: 5 ms Transient Response 12V output: 3 % Maximum deviation: Standby output: 3 % Turn-On Delay with Time required for initial output voltage stabilization after 1500 ms PS ON Signal application of AC input or ON/OFF signal. Output Regulation See Model Selection table. 1 Internal fan is considered part of the load as it is driven from the 12 V output Vaux load is set to 0.5 A for efficiency measurements. tech.support psbel.com