NOW PART OF D-Series Hydraulic-Magnetic Circuit Breaker PRODUCT WEBPAGE request sample, configure part, watch video DIN Rail Mounted Circuit Breaker The D-Series hydraulic-magnetic circuit breakers feature simple snap on back panel DIN rail mounting for easy assembly and removal. Added safety features round out this thoughtful breaker design with recessed wire ready terminals that are both touch proof and shock resistant. D-Series breakers are available as a one to four pole breaker, rated up to 50 amps, 480Y/277VAC or 80VD and with a max IC of 5,000 amps. 1-4 0.02-50 80 480Y Poles Amps VDC Max VAC Max Typical Applications Industrial Controls Renewable Energy www.carlingtech.com 860.793.9281 sales carlingtech.comTech Specs Mechanical Electrical Endurance 10,000 ON-OFF operations 6 Maximum Voltage AC, 480Y VAC per minute with rated current & (See Table A), 50/60 Hz, 80VDC voltage. Standard Current Coils 0.100, 0.250, 0.500, 0.750, 1.00, Trip Free All D-Series circuit breakers will 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, trip on overload, even when 25.0, 30.0, 35.0, 40.0 & 50.0. actuator is forcibly held in the ON Other ratings available - consult position. factory. Trip Indication The operating actuator moves Standard Voltage Coils DC - 6V, 12V AC - 120V, other positively to the OFF position ratings available, see ordering when an overload causes the scheme. breaker to trip. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one Physical minute between all electrically isolated terminals. D-Series Number of Poles Rocker Type: 1-3 Handle Type: circuit breakers comply with the 1-4 8mm spacing and 3750V 50/60 Internal Circuit Config. Switch Only and Series Trip with Hz dielectric requirements from hazardous voltage to operator current or voltage trip coils. accessible surfaces and between Weight Approximately 128 grams/pole adjacent poles per Publications (Approximately 4.57 ounces/pole) EN 60950 and VDE 0805. Standard Colors Housing - Black Actuator - See Resistance, Impedance Values from Line to Load Terminal Ordering Scheme. based on Series Trip Circuit Breaker Mounting Mounts on a standard 35mm Symmetrical DIN Rail (35 x 7.5 or RESISTANCE, IMPEDANCE VALUES 35 x 15mm per DIN EN5002). RESISTANCE PER POLE VALUES from Line to Load Terminals from Line to Load Terminals (Values Based on Series Trip Circuit Breaker (Values Based on Series Trip Circuit Breaker) 1000 CURRENT TOLERANCE Environmental (AMPS) (%) 100 Designed and tested in accordance with requirements of 0.10 - 5.0 15 specification MIL-PRF-55629 & MIL-STD-202 as follows: 10 5.1 - 20.0 25 Shock Withstands 100 Gs, 6ms, sawtooth O 20.1 - 50.0 35 1 while carrying rated current per H M Method 213, Test Condition I. S Instantaneous and ultra-short 0.1 curves tested 90% of rated current. 0.01 Vibration Withstands 0.060 excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at 0.001 0.01 0.1 1 10 100 rated current per Method 204C, AMPERE RATING Test Condition A. Instantaneous and ultra-short curves tested at 90% of rated current. Pulse Tolerance Curves Moisture Resistance Method 106D, i.e., ten 24-hour 60 Hz 1/2 Cycle cycles + 25C to +65C, 80- Inrush Pulse Tolerance I 98% RH. r 50 Hz 1/2 Cycle Time Delay Curves 42, 44 & 46 Inrush Pulse Tolerance I r (50 Amps Max.) Time Delay Curves 25x Salt Spray Method 101, Condition A (90-95% 22x 42, 44 & 46 (50 Amps Max.) RH 5% NaCl Solution, 96 hrs). Time Delay Curves Time Delay Curves 22, 24, 26 (70 Amps Max.) 12x 10x 22, 24 (100 Amps Max.) 26 (70 Amps Max.) Thermal Shock Method 107D, Condition A (Five t t cycles -55C to +25C to +85C 10.0 20.0 5.0 8.33 4.165 16.67 to +25C). Time in Time in Milliseconds Milliseconds Operating Temperature -40 C to +85 C 2. *Manufacturer reserves the right to change product specification without prior notice. Multiple of Rated Current Multiple of Rated Current