Safety Modules Safety Gate and Safety Magnetic Sensor Types NSO02D, NSO13D Safety Category 4, Performance Level e, according to EN 13849-1 Safety Category 4 according to EN 954-1 Category 0 Emergency Stop (EN 60204-1) Input type: 2 NO 2 x 6 A NO safety outputs (NSO02D) 3 x 6 A NO safety outputs and 1 x 6 A NC auxiliary output (NSO13D) Automatic / manual or monitored manual reset Single / double channel operations LED indication for outputs status and power supply ON Connection by fixed or detachable terminals For mounting on DIN-rail in accordance with DIN/EN 50 022 22.5 mm Euronorm housing Screw, fixed Screw, detachable Product De scrip tion Ordering Key N SO 0 2 D B24 S A Safety gate and safety Performance Level e, Housing magnetic sensor modules includes fixed screw and Function according to EN 60204-1, EN detachable screw as well as Auxiliary outputs 292-1/-2, EN 418 andautomatic/manual or Safety outputs EN1088. monitored manual restart Safety category This family of safety module versions. Power supply in Safety Category 4, Terminals Start/Reset type Type Selection Auxiliary Safety Terminals Start/Reset type Supply: 24 VAC/DC outputs outputs 2 NO Screw, fixed Automatic / Manual N SO 0 2 D B24 S A 2 NO Screw, fixed Monitored manual N SO 0 2 D B24 S C 2 NO Screw, detachable Automatic / Manual N SO 0 2 D B24 D A 2 NO Screw, detachable Monitored manual N SO 0 2 D B24 D C 1 NC 3 NO Screw, fixed Automatic / Manual N SO 1 3 D B24 S A 1 NC 3 NO Screw, fixed Monitored manual N SO 1 3 D B24 S C 1 NC 3 NO Screw, detachable Automatic / Manual N SO 1 3 D B24 D A 1 NC 3 NO Screw, detachable Monitored manual N SO 1 3 D B24 D C Time Specification Output Specification Delay ON energisation < 150 ms Safety outputs Category 4, Performance Level e (EN 13849-1) Delay ON de-energisation < 30 ms NSO02D 2 NO (13-14, 23-24) Recovery time 30 ms NSO13D 3 NO (13-14, 23-24, 33-34) Channel simultaneity Auxilary output during outputs closing Infinite NSO13D 1 NC (41-42) Input operating to START Rated insulation voltage 250 VAC (rms) operating delay Contact ratings (AgSnO ) 2 m Au NSO...C > 500 ms 2 Safety outputs Resistive loads AC1 6 A 230 VAC DC12 6 A 24 VDC Input Specifications Small inductive loadsAC15 3 A 230 VAC DC13 2.5 A 24 VDC Function 2 NO, voltage free Auxiliary output 6A, 24 VAC/DC Input current External contact fuse Terminals S11-S12 max 10 mA protection 5 A fast, 4 A slow Terminals S21-S22 max 10 mA 7 Mechanical life > 10 operations External contact resistance 5 Terminals S11-S12 max. 60 Electrical life > 10 operations Terminals S21-S22 max. 60 Dielectric strength Dielectric voltage 4 kVAC (rms) 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 27/09/12 NSO02D, NSO13D Supply Specification General Specifications Power supply Overvoltage cat III Indication for Rated operational volatge (IEC 60664) Power supply ON LED, green through terminal: Output relays ON LED, green (CH 1, CH2) A1, A2 24VAC - 15% / 10%, Environment (EN 60529) 50 to 60 Hz Degree of protection IP 20 24 VDC - 15% / +10% Pollution degree 2 Short circuit protection Internal PTC Operating temperature -25 to 65C, R.H. < 95% Storage temperature -30 to 65C, R.H. < 95% Dielectric voltage DC supply AC supply Supply to input none none Mimimum protection degree Supply to output 4 kV 4kV of the installation location IP 54 Input to output 4kV 4kV Housing dimensions 22.5 x 99 x 114 mm Rated operational voltage max 5 VA Weight Approx. 200 g Screw terminals Tightening torque Upper terminals Max. 0.5 Nm Lower terminals Max 0.8 Nm Approvals CULUS, TUV CE Marking Yes EMC Electromagnetic Compatibillity Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Mode of Operation The safety modules NSO02D Automatic START Manual START Monitored manual START and NSO13D monitor both Provided that the terminals X1 Provided that both S1 and S2 The monitored manual START mechanical switches and and X2 (NSO02...A) or S33 switches are closed, the safety versions (NSO...C) work as safety magnetic sensors (2 NO and S34 (NSO13...A) are outputs close and the auxiliary described in the previous contact outputs), according to connected, the safety outputs output opens (NSO13...A) as paragraph (Manual START) 98/37/CE Machinery Directive. close and the auxiliary output soon as the NO START except for a minimum delay of If the unit is correctly supplied opens (NSO13...A) as soon as pushbutton is pushed 500 ms from the closed status and the input terminals are both S1 and S2 switches are connecting X1 and X2 of the input contacts to the closed (i.e. safety gate closed), closed. (NSO02...A) or S33 and S34 pushing of the START button. the module is enabled to close The relevant CH1 and CH2 (NSO13...A) If the input terminals get the safety outputs and the LED turn on. A new operating cycle is closed with the START switch external contactors can be Releasing even one input possible only after releasing already closed, the safety energized. contact (S1 and/or S2) forces both input contacts, closing outputs dont close and the When the input terminals are immediately the safety outputs them again and pushing the auxiliary doesnt open open (i.e. safety gate open) the to open and the auxiliary START button. (NSO13...C): it is necessary to module is not enabled to close output (NSO13...A) to close. release the START button and the safety outputs and the A new operating cycle is the input contacts before external contactors can not be possible only after releasing starting a new cycle, then energized. both input contacts and then operate the input contacts and operating them again. finally, after at least 500 ms, operate the START button. So if the NO START button gets welded, the outputs dont close anymore. Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 27/09/12 2