Type 716P, Orange Drop, Polypropylene Film/Foil Capacitors High Performance Features Copper leads. Extremely low dissipation factor. Superb high frequency response. Excellent stability, virtually linear Insulation Resistance: temperature coefficient. 400,000 M minimum at +25C 20,000 M minimum at +85C Various lead spacings, crimp styles 2,000 M minimum at +105C and lead lengths available. Pulse Rise Time, dV/dt: See tabulated data. Specifications Capacitance Range: Corona Start Voltage (typical): 220 pF to 1.0 F See tabulated data. Capacitance Tolerance: Encapsulation: 3% to 10% Conformal coating of flame retardant orange epoxy (meets UL94V-0 specifications) Voltage Ratings: 100 to 2000 Volts D-C Dielectric: 70 to 500 Volts A-C Polypropylene film. Operating Temperature Range: Construction: -55C to +85C Non-inductively wound with extended (+105C with proper voltage derating) foil. Additional details on general specifications page. Lead Wire: Tinned copper. Applications: Switching and high voltage power Dissipation Factor: supplies, inverters, snubbers, resonant See tabulated data. converters and electronic lighting ballasts. CDE Cornell Dubilier 1605 E. Rodney French Blvd. New Bedford, MA 02744 Phone: (508)996-8561 Fax: (508)996-3830 Type 716P, Orange Drop, Polypropylene Film/Foil Capacitors High Performance General Specifications The 715P and 716P series are manufactured with polypropylene film and extended foil. Polypropylene has a very low dissipation factor, low dielectric absorption and exhibits excellent capacitance stability. These characteristics combined with the direct connection of the lead wire to the extended foil electrode makes the 715P and 716P series ideal for high current, high pulse applications. The 715P series has a round profile and is available in tolerances as close as 1%. The 716P series has a pressed profile and, in addition, is designed with copper leads, thus adding to it s performance in high frequency, high pulse current applications. Other specifications are listed below and on the following pages. Humidity Testing: Operating Temperature Range: Units subjected to 95% relative humidity for 72 The standard operating temperature range for hours with no voltage applied at +75C. After 4 polypropylene film is -55C to +85C. The hours of drying minimum product of insulation 715P and 716P may be operated up to +105C resistance and capacitance shall be 50,000 megohm- provided the DC working voltage is reduced microfarads. by 50%. For specific derating of the AC voltage when DC Voltage Life Test: operating above +85C please contact our Minimum of 500 hours at +85C at 150% of rated design engineering department. voltage. After test, capacitance shall not have changed by more than 3%, insulation resistance shall The maximum operating temperature for 715P not have decreased by more than 25% and dissipation and 716P polypropylene film capacitors is factor shall not have changed by more than 0.03%. + 105C. Measurements made at 1 KHz. Dielectric Withstanding Voltage: AC Voltage Life Test: Units rated below 800 VDC shall withstand Minimum of 500 hours at +85C at 60 Hz. AC test a DC potential of 250% of rated voltage applied voltage applied at 110% of AC rating. After test, between terminals for not more than 5 seconds capacitance shall not have changed by more than 3%, units rated 800 VDC and above shall withstand insulation resistance shall not have decreased by 200% of rated voltage. more than 25%, and dissipation factor shall not have changed by more than 0.03%. Measurements made Construction: at 1 KHz. Units rated 100 through 600 VDC are single section designs constructed of plain polypropylene Additional notes on Life Testing: film with extended foil. Units rated 800 VDC CDE performs standard 500 hour accelerated life tests, and above are series-section designs with extended both DC and line frequency AC, to monitor process foil and incorporate a floating common of control over our wide range of products. metallized polypropylene. All units are non- inductively wound. We also perform longer term life testing, typically 2000 hours, during development of most products. In Temperature Coefficient: addition we do accelerated life testing at 10-250 KHz The typical temperature coefficient is -180 ppm/C for our High Performance AC products. For additional over the temperature range of -55C to +85C. life test information please contact us. CDE Cornell Dubilier 1605 E. Rodney French Blvd. New Bedford, MA 02744 Phone: (508)996-8561 Fax: (508)996-3830