02/11/2015 www.crouzet.com
Modem communication plug and play solutions M3MOD Part number 88970117
For remote control of your application
Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
Millenium 3 program can be downloaded, modified and sent
Input and output states, as well as all program values, can be polled and controlled remotely
2 types of pre-configured ready-to-use modem:
- STN modem for wired transmission networks
- GSM modem for wireless communication
Part numbers
Type Description Supply
88970117 M3MOD Modem communication interface 12-24 V DC
Specifications
General environment characteristics for CB, CD, XD, XB, XR and XE product types
Certifications CE, UL, CSA, GL
Conformity to standards (with the low voltage directive IEC/EN 61131-2 (Open equipment)
and EMC directive) IEC/EN 61131-2 (Zone B)
IEC/EN 61000-6-2,
IEC/EN 61000-6-3 (*)
IEC/EN 61000-6-4
(*) Except configuration (889701.1 or 889701.2) + (88970250 or 88970270) + 88970241 class A (class B in a metal enclosure)
Earthing None
Protection rating In accordance with IEC/EN 60529:
IP40 on front panel
IP20 on terminal block
Overvoltage category 3 in accordance with IEC/EN 60664-1
Pollution Degree: 2 in accordance with IEC/EN 61131-2
Max operating Altitude Operation: 2000 m
Transport: 3,048 m
Mechanical resistance Immunity to vibrations IEC/EN 60068-2-6, Fc test
Immunity to shock IEC/EN 60068-2-27, Fa test
Resistance to electrostatic discharge Immunity to ESD IEC/EN 61000-4-2, level 3
Resistance to HF interference Immunity to radiated electrostatic fields
IEC/EN 61000-4-3,
Immunity to fast transients (burst immunity)
IEC/EN 61000-4-4, level 3
Immunity to shock waves
IEC/EN 61000-4-5
Radio frequency in common mode
IEC/EN 61000-4-6, level 3
Voltage dips and breaks (AC)
IEC/EN 61000-4-11
Immunity to damped oscillatory waves
IEC/EN 61000-4-12
Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1
(*) Except configuration (889701.1 or 889701.2) + (88970250 or 88970270) + 88970241 class A (class B in metallic cabinet)
Operating temperature -20+55C(+40Cinanon-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2
Storage temperature -40+70CinaccordancewithIEC/EN60068-2-1 and IEC/EN 60068-2-2
Relative humidity 95% max. (no condensation or dripping water) in accordance with IEC/EN 60068-2-30
Mounting On symmetrical DIN profile, 35 x 7.5 mm and 35 mm x 15 or panel (2 x 4 mm )
Screw terminals connection capacity Flexible wire with ferrule =
2
1 conductor: 0.25 to 2.5 mm (AWG 24...AWG 14)
2
2 conductors 0.25 to 0.75 mm (AWG 24...AWG 18)
Semi-rigid wire =
2
1 conductor: 0.2 to 2.5 mm (AWG 25...AWG 14)
Rigid wire =
2
1 conductor: 0.2 to 2.5 mm (AWG 25...AWG 14)
2
2 conductors 0.2 to 1.5 mm (AWG 25...AWG 16)
Tightening torque =
0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm)
Characteristics of the communication Modem system
General characteristics 88970117 88970118 88970119
Certifications CE, UL, CSA CE, UL, CSA CE, R&TTE, UL, CSA, FCC, IC
Supply
Nominal voltage (V) 1224VDC 1224VDC 1224VDC
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected02/11/2015 www.crouzet.com
Operating limits -13% / +20% -13% / +5% -54% / +33%
or1028,8VDC or1030VDC or5,532VDC
Ripple 5% max. - -
Nominal current under 12 V DC 30mA 140mA 165mA
Nominal current under 24 V DC 30mA 70mA 87mA
Peak current on energisation 550mA 9600mA 2100mA at 5.5 V
Max. absorbed power 1,1 W 1,7 W 2,1 W
Immunity from micro power cuts 1 ms, repetition 20 times - -
Protection against polarity inversions Yes No No
Fuse protection 1 A fuse - Supplied with fuse 2.5 A
Temperature Use (C) -20+55C -30+70C -20+55C
Storage temperature (C) -40+70C -40+85C -25+70C
Characteristics of theCOM-M3" link with the controller
Type of connector Specific Millenium
Type of link Specific Millenium communication protocol
Compatibility OnlywithMilleniumcontrollersversionV2.1
Isolation ofCom-M3" connector from theCom-
Via optocoupler AC 1780 V
connector
Isolation ofCom-M3" connector from the supply
Via optocoupler AC 1780 V
terminals
Characteristics ofCom- link with the Modem
Type of connector Specific Millenium
Type of link with Modem connector cable RS 232 serial (supplied with the communication interface)
Compatibility OnlywithMilleniumcontrollersversionV2.1
Analogue RTC modem compatibility AT commands
GSM modem compatibility AT commands
Isolation ofCom- connector from the Modem Via link cable to Modem (supplied)
Isolation ofCom- connector from the supply
Via link cable to Modem (supplied)
terminals
Data characteristics
Data saved by the interface Up to 28 messages
1 to 10 recipients (telephone numbers and/or e-mail addresses) per message
Time-stamping of messages to be sent (date and time)
Saving of values on triggering of the message activation condition (digital and numerical values)
Backup of data to be sent Flash memory
Comments
88970117: supplied with connecting cable between
M3MOD and Modem (Millenium 3 connector to sub DB9)
88970118: supplied with configuaration CD-ROM and
telephone cable
88970119: supplied with an antenna, a power cable, and
DIN Rail mounting kit
Processing characteristics of CB, CD, XD & XB product
types
LCD display CD, XD: Display with 4 lines of 18 characters
Programming method Function blocks / SCF (Grafcet) or Ladder
Program size For CB, CD:
4 Ko: 64 macros max.
256 blocks max. per macro
180 typical blocks
For XB, XD:
8 Ko: 64 macro max.
256 blocks max. per macro
350 typical blocks
Or for CB, CD, XB, XD: 120 lines in Ladder
Program memory Flash EEPROM
Removable memory EEPROM
Data memory 368 bit/200 words
Back-up time in the event of power failure Program and settings in the controller: 10 years
Program and settings in the plug-in memory: 10 years
Data memory: 10 years
Cycle time Functionblocks:690ms(typically20ms)
Ladder: typically 20 ms
Response time Input acquisition time: 1 to 2 cycle times
Clock data retention 10 years (lithium battery) at 25C
Clock drift Drift < 12 min/year (at 25C)
6 s/month (at 25C with user-definable correction of drift)
Timer block accuracy 1% 2 cycle times
Start up time on power up < 1,2 s
Characteristics of products with AC power supplied
Supply 24 V AC 100240VAC
(88970..4) (88970..3)
Nominal voltage 24 V AC 100240VAC
Operating limits -15% / +20% -15% / +10%
or20.4VAC28.8VAC or85VAC264VAC
Supply frequency range 50/60Hz (+4% / -6%)
50/60Hz (+4% / -6%)or4753Hz/57<63Hz
or4753Hz/57<63Hz
Immunity from micro power cuts 10 ms (repetition 20 times) 10 ms (repetition 20 times)
Max. absorbed power CB12-CD12-XD10-XB10: 4 VA CB12-CD12-XD10-XB10: 7 VA
CB20-CD20: 6 VA CB20-CD20: 11 VA
XD10-XB10 with extension: 7,5 VA XD10-XB10 with extension: 12 VA
XD26-XB26: 7.5 VA XD26-XB26: 12 VA
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected