BL1R Timers Syrline 17.5 mm - 1 Relay 16A Multi-function or mono-function Multi-range (12 function) Multi-voltage 12 240 V AC/DC LED status indicator (relay version) P ossibility of external load connection in parallel to the control input 3-wire PNP sensor compatible Specifications Functions Delay Output Nominal rating Connections Supply voltage Code L - Li 0,1 s 10 days 1 changeover relay 16 A Screw terminals 12 240 V / BL1R16MV1 Output relay Contact arrangement 1 CO (SPDT) (Changeover -Single Pole Double Throw-) Maximum switching voltage 250 VAC/ 16 A resistive / 250 VDC / 0.3 A resistive Switching current rate (resistive) NO / NC: 16 A 250 V AC / 16 A 30 VDC 25C NO / NC: 8 A 250 V AC / 8 A 30 VDC 60C Minimum switching contact 10 mA / 5 VDC Maximum switching power (resistive) 4000 VA / 90 W 25C 3 Electrical life 30x10 cycles (NO) at 250 VAC/ 16 A resistive Maximum rate (at max switching power) 360 cycles /hour 6 Mechanical life 30 x 10 cycles Rated impulse voltage 5 kV (1.2/50s) Dielectric strength between coil / contacts IEC 60664-1: 5 kV /1 min / 1 mA / 50 Hz Dielectric strength between open contacts 1 kV /1 min / 1 mA / 50 Hz Timing Timing ranges (7 ranges) 0.510s, 0.051min, 0.510min, 0.051h, 0.510h, 0.051day, 0.510days Minimum pulse duration typically (relay version) IEC 1812-1: 30 ms / 100 ms with load Maximum reset time by de-energisation typically (relay version) IEC 1812-1: 120 ms Repeatability IEC 1812-1: 0,5 % Repetition accuracy with constant parameters IEC 1812-1: 10 % Drift Temperature 0.05 % / C Voltage-dependent drift 0.2 % / V Supply Multi-voltage power supply 12240 V/ Operating range 15 %, +10 % Operating frequency (Hz) 50 / 60 Hz 5 %I Timers I 02 I www.crouzet-control.com Supply Galvanic isolation No Max. absorbed power Approx. 3 VA (V) 1.5 W (V) Immunity from micro power cuts 10 ms General characteristics Insulation voltage, IEC 60664-1 300 V Installation category (acc. to IEC/EN 60664-1) Overvoltage category III pollution degree 2 Impulse voltage CEI/EN 60664-1 4 kV (1,2 / 50 s) Clearance / Creepage distances IEC 60664-1: 3 mm / 3.2 mm Breakdown voltage EN-61812-1: 2,5 kV / 1 min / 1 mA / 50 Hz Insulation resistance NFC 93 050: > 500 M / 250 V / 1min Status indication Un: green LED blinks when count, continuous ON when supplied R: yellow LED continuous ON when the relay is ON Casing DIN 43880: 17,5 mm Fixing: Symmetrical DIN rail EN 50022: 35 mm Mounting position All positions Housing material Enclosure plastic type UL94 - V0 Protection (IEC/EN 60529) Housing: IP40 / Terminal block: IP20 Terminal capacity Single-wire without ferrule IEC 60947-1 1 x 0.5 3.3 mm (AWG 20 AWG 12) 2 x 0.5 1.5 mm (AWG 20 AWG 16) Max. tightening torque (Nm) IEC 60947-1 0,5 N.m / 4,4 lbf.in Operating temperature range (C) IEC 60068-2: -20 C +60 C Storage temperature range (C) IEC 60068-2: -40 C +70 C Relative humidity no condensation acc. to IEC/EN 60068-2-30 93 % without condensation Vibration resistance according to IEC/EN 60068-2-6 0.15 mm from 10 Hz 60 Hz 2g from 60 Hz 150 Hz Impact resistance IEC 60068-2-27 15gn - 11ms 3 x 6 axis (output OFF) 5gn - 11ms 3 x 6 axis (Output ON) Drop to concrete floor IEC 60068-2-32 High: 0.75m Weight: casing 17,5 mm 70 g 80 g with packaging Directives 2014/30/EU: EMC 2014/35/EU: low voltage Certifications CE - cULus Listed Industrial Control Equipment - CCC Conformity to standards CEI 60664-1: Insulation coordination for equipment within low-voltage systems CEI 61812-1/ Specified time relays for industrial use UL 60947-4-1/ Industrial Control Equipment (NRNT- Industrial Control Switches) Conformity with environmental directives 2015/863/UE: RoHS 1907/2006: Reach 2012/19/UE: WEEE Electromagnetic compatibility IEC 61000-6-2, IEC 61000-6-3, Immunity for industrial environment IEC 61000-6-4 Emission residential environment Emission industrial environment Electromagnetic compatibility - Immunity to electrostatic discharges Level III Air 8 KV / Contact 6 KV acc to IEC/EN 61000-4-2 Immunity to radiated, radio-frequency, electromagnetic field acc. Level III IEC/EN 61000-4-3 10 V/m (80 M Hz to 1 G Hz) 80 % AM (1 k Hz) 3 V/m (1,4 2 G Hz) 80 % AM (1K Hz) 1V/m (2 2.7 G Hz) 80 % AM (1K Hz)