PLA110
Single Pole, Normally Open
OptoMOS Relay
INTEGRATED CIRCUITS DIVISION
Parameters Ratings Units Description
Blocking Voltage 400 V PLA110 is a normally open (1-Form-A) solid
P
state relay that uses optically coupled MOSFET
Load Current 150 mA / mA
rms DC
technology to provide 3750V of input to output
On-Resistance (max) 22 rms
isolation. Its optically coupled outputs, which use the
patented OptoMOS architecture, are controlled by a
highly efficient GaAIAs infrared LED.
Features
3750V Input to Output Isolation
The PLA110 can be used to replace mechanical
rms
Low Drive Power Requirements
relays, and offers the superior reliability associated
(TTL/CMOS Compatible)
with semiconductor devices. Because it has no
No Moving Parts
moving parts, it offers faster, bounce-free switching
High Reliability
in a more compact surface mount or thru-hole
Arc-Free With No Snubbing Circuits
package.
No EMI/RFI Generation
FCC Compatible
Approvals
VDE Compatible
UL Recognized Component: File E76270
Small 6-Pin Package
CSA Certified Component: Certificate 1175739
Machine Insertable, Wave Solderable
EN/IEC 60950-1 Certified Component:
TUV Certificate B 09 07 49410 004
Applications
Ordering Information
Telecommunications
Telecom Switching
Part # Description
Tip/Ring Circuits
PLA110 6-Lead DIP (50/Tube)
Modem Switching (Laptop, Notebook, PocketSize)
PLA110S 6-Lead Surface Mount (50/Tube)
Hook Switch
PLA110STR 6-Lead Surface Mount (1000/Reel)
Dial Pulsing
Ground Start
Ringing Injection
Pin Configuration
Instrumentation
AC/DC Configuration
Multiplexers
1 6
+ Control Load
Data Acquisition
2 5
- Control Do Not Use
Electronic Switching
3 4
NC Load
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
DC Only Configuration
Medical Equipment Patient/Equipment Isolation
1 6
Security + Control + Load
2 5
Aerospace - Control - Load
3 4
Industrial Controls NC
Switching Characteristics of
Normally Open Devices
Form-A
I
F
90%
10%
I
LOAD
t t
on off
Pb
e3
DS-PLA110-R07
1
www.ixysic.comPLA110
INTEGRATED CIRCUITS DIVISION
Absolute Maximum Ratings @ 25C
Absolute Maximum Ratings are stress ratings. Stresses in
Parameter Min Max Units
excess of these ratings can cause permanent damage to
Blocking Voltage - 400 V
P
the device. Functional operation of the device at conditions
Reverse Input Voltage - 5 V
beyond those indicated in the operational sections of this
Input Control Current - 50 mA data sheet is not implied.
Peak (10ms) - 1 A
1
Input Power Dissipation - 150 mW
2
Total Package Dissipation - 800 mW
Isolation Voltage, Input to Output 3750 - V
rms
Operational Temperature -40 +85 C
Storage Temperature -40 +125 C
1
Derate linearly 1.33 mW / C
2
Derate linearly 6.67 mW / C
Electrical Characteristics @ 25C
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous, AC/DC Configuration - - - 150 mA / mA
rms DC
I
L
Continuous, DC Configuration - - - 250 mA
DC
Peak t=10ms I - - 400 mA
LPK P
On-Resistance
AC/DC Configuration I =150mA -- 22
L
R
ON
DC Configuration I =250mA - - 7
L
Off-State Leakage Current V =400V I -- 1 A
L P LEAK
Switching Speeds
Turn-On t -- 1
on
I =5mA, V =10V ms
F L
Turn-Off t - - 0.5
off
Output Capacitance V =50V, f=1MHz C -25 - pF
L OUT
Input Characteristics
Input Control Current to Activate I =150mA I -- 5 mA
L F
Input Control Current to Deactivate - I 0.4 0.7 - mA
F
Input Voltage Drop I =5mA V 0.9 1.2 1.4 V
F F
Reverse Input Current V =5V I -- 10 A
R R
Common Characteristics
Input to Output Capacitance - C -3 - pF
I/O
R07
2 www.ixysic.com